Equivalent & Substitute Parts for Cosel USA, Inc. ZUS102415 DC DC Converter

Part Overview

Cosel USA, Inc. ZUS102415 is an isolated module DC-DC converter providing a single output of 15V at up to 700mA from an 18V to 36V input range. The device is designed for ITE (Commercial) applications and features overcurrent protection (OCP), 500V isolation rating, and an 82% efficiency. The ZUS102415 features through-hole mounting and a 4-DIP module package, with physical dimensions of 1.77" x 1.38" x 0.28" (45.0mm x 35.0mm x 7.0mm). It is RoHS3 compliant, with inventory listed as 1314 pieces in stock, but is classified as obsolete, necessitating identification of substitutable models for new designs and maintenance.

Substiute Parts

ZUS102415
Cosel USA, Inc.In Stock: 1407ZUS102415 Datasheet
ZUS102415
Current Part
MGS102415
Cosel USA, Inc.In Stock: 1190MGS102415 Datasheet
MGS102415
Similar

Key Parameters

Parameter ZUS102415
Manufacturer Cosel USA, Inc.
Series ZUS (10W)
Product Status Obsolete
Type Isolated Module
Number of Outputs 1
Voltage - Input (Min) 18V
Voltage - Input (Max) 36V
Voltage - Output 1 15V
Current - Output (Max) 700mA
Voltage - Isolation 500 V
Applications ITE (Commercial)
Features OCP
Operating Temperature -20°C ~ 71°C (With Derating)
Efficiency 82%
Mounting Type Through Hole
Package / Case 4-DIP Module
Size / Dimension 1.77" L x 1.38" W x 0.28" H (45.0mm x 35.0mm x 7.0mm)
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) Not Applicable

Substitute Part Grouping Explanation

Substitution for Cosel USA, Inc. ZUS102415 must be based strictly on matching the following key parameters: input voltage range, output voltage and current, isolation voltage, mounting type, package/case type, compliance, number of outputs, application suitability, and feature set. Only models meeting the allowed electrical and mechanical specifications as provided are considered equivalent or substitutable.

Parameters employed for substitution:

  • Number of Outputs: 1
  • Voltage - Input (Min): 18V
  • Voltage - Input (Max): 36V
  • Voltage - Output 1: 15V
  • Current - Output (Max): 700mA
  • Voltage - Isolation: ≥ 500V
  • Applications: ITE (Commercial)
  • Features: Includes OCP
  • Mounting Type: Through Hole
  • RoHS Status: ROHS3 Compliant

Parameter Comparison

Parameter ZUS102415 MGS102415
Manufacturer Cosel USA, Inc. Cosel USA, Inc.
Series ZUS (10W) MGS (10W)
Product Status Obsolete Active
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 18V 18V
Voltage - Input (Max) 36V 36V
Voltage - Output 1 15V 15V
Current - Output (Max) 700mA 700mA
Voltage - Isolation 500 V 1.5 kV
Applications ITE (Commercial) ITE (Commercial)
Features OCP Remote On/Off, OCP
Operating Temperature -20°C ~ 71°C (With Derating) -40°C ~ 85°C (With Derating)
Efficiency 82% 90%
Mounting Type Through Hole Through Hole
Package / Case 4-DIP Module 7-SIP Module
Size / Dimension 1.77" L x 1.38" W x 0.28" H (45.0mm x 35.0mm x 7.0mm) 0.87" L x 0.37" W x 0.47" H (22.0mm x 9.5mm x 12.0mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) Not Applicable Not Applicable

Engineering Selection Recommendations

ZUS102415 is classified as obsolete. For projects requiring active production status, substitute part MGS102415 should be considered, as it is active and maintains RoHS3 compliance and Not Applicable MSL. All certifications listed (ECCN EAR99, HTSUS 8504.40.9580) are identical. Be sure that only substitute parts verified by the provided parameters are selected for continued RoHS3 compliant designs and inventories.

Frequently Asked Questions (FAQ)

Q1: What defines the equivalency between ZUS102415 and substitute parts?
Equivalency is strictly defined by matching the provided electrical and mechanical parameters: input voltage range, output voltage/current, isolation voltage, mounting type, feature set, compliance, and application suitability.

Q2: Are package differences relevant for substitution?
Substitution is permitted when the mounting type (Through Hole) is consistent. Actual module format and dimensions differ, and should be evaluated within allowed mechanical constraints provided.

Q3: Is compliance (e.g., RoHS3) maintained for substitute parts?
All substitute parts listed are RoHS3 compliant, matching the main part's compliance level.

Q4: How do current or output specifications affect substitute compatibility?
Substitute parts must provide the same output voltage (15V) and maximum output current (700mA), strictly adhering to the original design specification.

Q5: Are there any functional feature changes in listed substitutes?
Both main and substitute models include overcurrent protection (OCP) per provided feature lists, ensuring required safety and protection functions are maintained. Any additional features are specified in the input and are not grounds for exclusion if the core feature set is present.

Request Quote (Ships tomorrow)