XPCL10DC Equivalent & Substitute Parts Reference

Part Overview

The XPCL10DC is a differential pressure sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for board mount applications with a 0.36 PSI (2.49 kPa) operating pressure range and 0 mV to 20 mV output signal at 12V supply. The sensor features temperature compensation and Wheatstone Bridge output configuration in a 4-SIP module package.

This part is classified as obsolete. Identifying equivalent substitute components is necessary to maintain system functionality, ensure continued availability, and support ongoing production or maintenance requirements for applications utilizing this sensor specification.

Substiute Parts

XPCL10DC
Honeywell Sensing and Productivity SolutionsIn Stock: 1127XPCL10DC Datasheet
XPCL10DC
Current Part
10 INCH-D-CGRADE-MINI
Amphenol All Sensors CorporationIn Stock: 102510 INCH-D-CGRADE-MINI Datasheet
10 INCH-D-CGRADE-MINI
Similar

Key Parameters

Parameter Value
Pressure Type Differential
Operating Pressure 0.36 PSI (2.49 kPa)
Output Type Wheatstone Bridge
Output Signal Range 0 mV ~ 20 mV (12V)
Accuracy ±1%
Supply Voltage Range 3V ~ 16V
Operating Temperature Range -25°C ~ 85°C
Package Type 4-SIP Module
Mounting Type Through Hole
Features Temperature Compensated
RoHS Status RoHS Compliant

Substitute Part Grouping Explanation

Substitute components for the XPCL10DC are identified based on strict parameter matching across the following critical specifications:

Core Matching Criteria:

  • Pressure Type: Differential
  • Operating Pressure: 0.36 PSI (2.49 kPa)
  • Output Type: Wheatstone Bridge
  • Output Signal Range: 0 mV ~ 20 mV (12V)
  • Accuracy: ±1%
  • Package Type: 4-SIP Module
  • Mounting Type: Through Hole
  • Temperature Compensation: Required
  • Operating Temperature Range: -25°C ~ 85°C
  • RoHS Compliance: Required

The 10 INCH-D-CGRADE-MINI manufactured by Amphenol All Sensors Corporation meets all core electrical and mechanical parameters required for substitution. This part maintains identical pressure range, output characteristics, accuracy specification, and thermal operating envelope. Both components utilize Wheatstone Bridge output configuration and are housed in 4-SIP module packages suitable for through-hole board mounting.

Parameter Comparison

Parameter XPCL10DC (Honeywell) 10 INCH-D-CGRADE-MINI (Amphenol) Compatibility
Pressure Type Differential Differential Match
Operating Pressure 0.36 PSI (2.49 kPa) 0.36 PSI (2.49 kPa) Match
Output Type Wheatstone Bridge Wheatstone Bridge Match
Output Signal Range 0 mV ~ 20 mV (12V) 0 mV ~ 20 mV (12V) Match
Accuracy ±1% ±1% Match
Supply Voltage Range 3V ~ 16V 16V Compatible
Operating Temperature Range -25°C ~ 85°C -25°C ~ 85°C Match
Package Type 4-SIP Module 4-SIP Module Match
Mounting Type Through Hole Through Hole Match
Temperature Compensation Yes Yes Match
RoHS Status RoHS Compliant RoHS Compliant Match
Maximum Pressure 3 PSI (20.68 kPa) 5 PSI (34.47 kPa) Compatible
Port Configuration No Port Male - 0.18" (4.57mm) Tube, Dual Differs

Engineering Selection Recommendations

The 10 INCH-D-CGRADE-MINI is a valid substitute for the obsolete XPCL10DC based on electrical parameter equivalence and compliance certifications. Both components are RoHS compliant and maintain identical output characteristics, accuracy specifications, and thermal operating ranges required for direct functional replacement.

The substitute part is classified as active product status, ensuring continued availability and supply chain support. The higher maximum pressure rating (5 PSI versus 3 PSI) provides additional safety margin without affecting performance at the specified 0.36 PSI operating pressure.

Port configuration differs between the two components. The XPCL10DC features no port configuration, while the 10 INCH-D-CGRADE-MINI includes male barbless tube ports (0.18" / 4.57mm, dual). System integration requirements must account for this mechanical difference during component selection and installation.

Frequently Asked Questions (FAQ)

Q: Can the 10 INCH-D-CGRADE-MINI directly replace the XPCL10DC in existing applications?

A: Electrical substitution is valid. Both components provide identical 0 mV to 20 mV output at 12V supply with ±1% accuracy and operate across the same -25°C to 85°C temperature range. Mechanical integration must be evaluated due to port configuration differences. The XPCL10DC has no ports, while the substitute includes male barbless tube ports.

Q: What is the significance of the different maximum pressure ratings?

A: The XPCL10DC is rated to 3 PSI maximum, while the 10 INCH-D-CGRADE-MINI is rated to 5 PSI maximum. Both operate at 0.36 PSI nominal pressure. The higher rating on the substitute provides additional overpressure protection without affecting normal operating characteristics.

Q: Are both components RoHS compliant?

A: Yes. Both the XPCL10DC and 10 INCH-D-CGRADE-MINI are RoHS compliant, meeting environmental and regulatory requirements for electronic component manufacturing and deployment.

Q: What is the difference in supply voltage specifications?

A: The XPCL10DC accepts 3V to 16V supply range. The 10 INCH-D-CGRADE-MINI is specified at 16V. Both operate correctly at 12V nominal supply. System designs operating below 16V should verify compatibility with the substitute part's supply voltage specification.

Q: How do the package types compare?

A: Both components use 4-SIP module packages with through-hole mounting. Pin configuration and physical dimensions should be verified during PCB layout and assembly planning to ensure mechanical fit and electrical connectivity.

Q: What is the significance of the port style difference?

A: The XPCL10DC features no port configuration for pressure input. The 10 INCH-D-CGRADE-MINI includes dual male barbless tube ports (0.18" / 4.57mm). Applications requiring direct tube connection benefit from the substitute's integrated ports. Applications with alternative pressure coupling methods must accommodate this mechanical difference.

Request Quote (Ships tomorrow)