XPC150GTC Pressure Sensor Equivalent & Substitute Parts

Part Overview

The XPC150GTC is a vented gauge pressure sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for board mount applications requiring 150 PSI (1034.21 kPa) pressure measurement. The sensor outputs a Wheatstone Bridge signal of 0 mV to 90 mV at 12V supply voltage with ±1% accuracy and temperature compensation across -25°C to 85°C operating range.

The XPC150GTC carries an obsolete product status. Identifying equivalent substitute parts is necessary to ensure design continuity, maintain supply chain reliability, and support long-term system maintenance where direct replacement or design migration is required.

Substiute Parts

XPC150GTC
Honeywell Sensing and Productivity SolutionsIn Stock: 975XPC150GTC Datasheet
XPC150GTC
Current Part
TSCSHNN150PGUCV
Honeywell Sensing and Productivity SolutionsIn Stock: 864TSCSHNN150PGUCV Datasheet
TSCSHNN150PGUCV
Similar

Key Parameters

Parameter Value
Manufacturer Part Number XPC150GTC
Manufacturer Honeywell Sensing and Productivity Solutions
Product Status Obsolete
Operating Pressure 150 PSI (1034.21 kPa)
Pressure Type Vented Gauge
Output Type Wheatstone Bridge
Output Signal 0 mV ~ 90 mV (12V)
Accuracy ±1%
Supply Voltage 3V ~ 16V
Port Size Male - 0.19" (4.83 mm) Tube
Port Style Barbed
Temperature Compensation Yes
Termination Style PC Pin
Maximum Pressure 250 PSI (1723.69 kPa)
Operating Temperature -25°C ~ 85°C
Mounting Type Through Hole
Package / Case 4-SIP Module
RoHS Status RoHS Compliant
MSL Rating 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute parts for the XPC150GTC are identified based on strict alignment of the following critical parameters:

Pressure Specification Alignment:

  • Operating pressure rating of 150 PSI (1034.21 kPa)
  • Vented gauge pressure type
  • Wheatstone Bridge output configuration

Electrical Compatibility:

  • Output signal type and bridge configuration
  • Supply voltage range overlap with original specification
  • Temperature compensation feature

Mechanical Compatibility:

  • Port size and style (Male barbed 0.19" tube connection)
  • Through-hole mounting configuration
  • PC pin termination style
  • 4-SIP package form factor

Regulatory & Quality Compliance:

  • RoHS compliance status
  • MSL rating compatibility
  • ECCN and HTSUS classification alignment

Substitute parts must maintain functional equivalence across pressure measurement range, electrical interface, and physical mounting characteristics to ensure direct or near-direct replacement capability.

Parameter Comparison

Parameter XPC150GTC (Main Part) TSCSHNN150PGUCV (Substitute)
Manufacturer Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions
Product Status Obsolete Active
Operating Pressure 150 PSI (1034.21 kPa) 150 PSI (1034.21 kPa)
Pressure Type Vented Gauge Vented Gauge
Output Type Wheatstone Bridge Wheatstone Bridge
Output Signal 0 mV ~ 90 mV (12V) 0 mV ~ 45.75 mV (5V)
Accuracy ±1% ±0.15%
Supply Voltage Range 3V ~ 16V 1.5V ~ 12V
Port Size Male - 0.19" (4.83 mm) Tube Male - 0.19" (4.78 mm) Tube
Port Style Barbed Barbed
Temperature Compensation Yes Yes
Termination Style PC Pin PC Pin
Maximum Pressure 250 PSI (1723.69 kPa) 245 PSI (1689.22 kPa)
Operating Temperature -25°C ~ 85°C -40°C ~ 85°C
Mounting Type Through Hole Through Hole
Package / Case 4-SIP Module 4-SIP, Side Port
RoHS Status RoHS Compliant RoHS Compliant
MSL Rating 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

TSCSHNN150PGUCV as Primary Substitute:

The TSCSHNN150PGUCV is classified as an active product from Honeywell Sensing and Productivity Solutions, providing direct functional replacement for the obsolete XPC150GTC. Both sensors share identical operating pressure specifications (150 PSI vented gauge), Wheatstone Bridge output configuration, barbed male port connection (0.19" tube), PC pin termination, and through-hole mounting.

Compliance & Regulatory Status:

Both the XPC150GTC and TSCSHNN150PGUCV maintain RoHS compliance and MSL Level 1 (Unlimited) moisture sensitivity ratings, ensuring equivalent environmental and regulatory qualification for board-level applications.

Output Signal Considerations:

The TSCSHNN150PGUCV operates at 5V supply with 0 mV to 45.75 mV output, compared to the XPC150GTC's 12V supply with 0 mV to 90 mV output. The substitute provides improved accuracy (±0.15% versus ±1%) and extended low-temperature operating range (-40°C versus -25°C minimum). Signal conditioning or amplification may be required in systems designed for the original 90 mV output level.

Supply Voltage Compatibility:

The TSCSHNN150PGUCV supply voltage range (1.5V to 12V) overlaps with the XPC150GTC range (3V to 16V) within the 1.5V to 12V window, supporting direct substitution in systems operating within this common range.

Active Product Status:

Selection of the TSCSHNN150PGUCV ensures ongoing component availability, technical support, and supply chain continuity compared to the obsolete XPC150GTC.

Frequently Asked Questions (FAQ)

Q: Can the TSCSHNN150PGUCV directly replace the XPC150GTC without circuit modifications?

A: Both sensors share identical pressure ratings, vented gauge configuration, Wheatstone Bridge output type, barbed male port connection, and PC pin termination. However, the output signal levels differ (45.75 mV at 5V versus 90 mV at 12V). Direct mechanical and pneumatic replacement is possible; electrical signal conditioning may be required depending on downstream amplifier or ADC input specifications.

Q: What are the key compatibility criteria for pressure sensor substitution?

A: Critical parameters include operating pressure rating, pressure type (vented gauge), output signal type (Wheatstone Bridge), port size and style (male barbed 0.19" tube), supply voltage range overlap, termination style (PC pin), and mounting configuration (through-hole). Both sensors meet these criteria.

Q: How do accuracy specifications differ between these sensors?

A: The XPC150GTC specifies ±1% accuracy, while the TSCSHNN150PGUCV provides ±0.15% accuracy. The substitute offers improved measurement precision. System designs relying on the original ±1% specification will benefit from the tighter tolerance of the substitute.

Q: Are there temperature range differences affecting substitution?

A: The XPC150GTC operates from -25°C to 85°C; the TSCSHNN150PGUCV extends the minimum operating temperature to -40°C. Both share the 85°C maximum. The substitute supports broader low-temperature applications.

Q: What is the significance of the "Side Port" designation in the TSCSHNN150PGUCV package?

A: The TSCSHNN150PGUCV features a side port configuration within the 4-SIP package, compared to the standard 4-SIP module of the XPC150GTC. This affects PCB layout and mounting orientation. Physical board layout verification is necessary to confirm mechanical fit.

Q: Do both sensors maintain equivalent RoHS and MSL compliance?

A: Yes. Both the XPC150GTC and TSCSHNN150PGUCV are RoHS compliant with MSL Level 1 (Unlimited) ratings, ensuring equivalent environmental qualification and regulatory status for board-level deployment.

Q: What supply voltage should be selected for the TSCSHNN150PGUCV substitute?

A: The TSCSHNN150PGUCV operates across 1.5V to 12V supply range. For systems originally designed for 12V operation, 12V supply is compatible. For systems designed for 3V to 16V operation, the substitute functions within the 1.5V to 12V overlap window. Systems requiring supply voltages above 12V require alternative substitutes or external regulation.

Request Quote (Ships tomorrow)