Request Quote
(Ships tomorrow)
XPC150GTC Pressure Sensor Equivalent & Substitute Parts
Part Overview
The XPC150GTC is a vented gauge pressure sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for board mount applications requiring 150 PSI (1034.21 kPa) pressure measurement. The sensor outputs a Wheatstone Bridge signal of 0 mV to 90 mV at 12V supply voltage with ±1% accuracy and temperature compensation across -25°C to 85°C operating range.
The XPC150GTC carries an obsolete product status. Identifying equivalent substitute parts is necessary to ensure design continuity, maintain supply chain reliability, and support long-term system maintenance where direct replacement or design migration is required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | XPC150GTC |
| Manufacturer | Honeywell Sensing and Productivity Solutions |
| Product Status | Obsolete |
| Operating Pressure | 150 PSI (1034.21 kPa) |
| Pressure Type | Vented Gauge |
| Output Type | Wheatstone Bridge |
| Output Signal | 0 mV ~ 90 mV (12V) |
| Accuracy | ±1% |
| Supply Voltage | 3V ~ 16V |
| Port Size | Male - 0.19" (4.83 mm) Tube |
| Port Style | Barbed |
| Temperature Compensation | Yes |
| Termination Style | PC Pin |
| Maximum Pressure | 250 PSI (1723.69 kPa) |
| Operating Temperature | -25°C ~ 85°C |
| Mounting Type | Through Hole |
| Package / Case | 4-SIP Module |
| RoHS Status | RoHS Compliant |
| MSL Rating | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitute parts for the XPC150GTC are identified based on strict alignment of the following critical parameters:
Pressure Specification Alignment:
- Operating pressure rating of 150 PSI (1034.21 kPa)
- Vented gauge pressure type
- Wheatstone Bridge output configuration
Electrical Compatibility:
- Output signal type and bridge configuration
- Supply voltage range overlap with original specification
- Temperature compensation feature
Mechanical Compatibility:
- Port size and style (Male barbed 0.19" tube connection)
- Through-hole mounting configuration
- PC pin termination style
- 4-SIP package form factor
Regulatory & Quality Compliance:
- RoHS compliance status
- MSL rating compatibility
- ECCN and HTSUS classification alignment
Substitute parts must maintain functional equivalence across pressure measurement range, electrical interface, and physical mounting characteristics to ensure direct or near-direct replacement capability.
Parameter Comparison
| Parameter | XPC150GTC (Main Part) | TSCSHNN150PGUCV (Substitute) |
|---|---|---|
| Manufacturer | Honeywell Sensing and Productivity Solutions | Honeywell Sensing and Productivity Solutions |
| Product Status | Obsolete | Active |
| Operating Pressure | 150 PSI (1034.21 kPa) | 150 PSI (1034.21 kPa) |
| Pressure Type | Vented Gauge | Vented Gauge |
| Output Type | Wheatstone Bridge | Wheatstone Bridge |
| Output Signal | 0 mV ~ 90 mV (12V) | 0 mV ~ 45.75 mV (5V) |
| Accuracy | ±1% | ±0.15% |
| Supply Voltage Range | 3V ~ 16V | 1.5V ~ 12V |
| Port Size | Male - 0.19" (4.83 mm) Tube | Male - 0.19" (4.78 mm) Tube |
| Port Style | Barbed | Barbed |
| Temperature Compensation | Yes | Yes |
| Termination Style | PC Pin | PC Pin |
| Maximum Pressure | 250 PSI (1723.69 kPa) | 245 PSI (1689.22 kPa) |
| Operating Temperature | -25°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 4-SIP Module | 4-SIP, Side Port |
| RoHS Status | RoHS Compliant | RoHS Compliant |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
TSCSHNN150PGUCV as Primary Substitute:
The TSCSHNN150PGUCV is classified as an active product from Honeywell Sensing and Productivity Solutions, providing direct functional replacement for the obsolete XPC150GTC. Both sensors share identical operating pressure specifications (150 PSI vented gauge), Wheatstone Bridge output configuration, barbed male port connection (0.19" tube), PC pin termination, and through-hole mounting.
Compliance & Regulatory Status:
Both the XPC150GTC and TSCSHNN150PGUCV maintain RoHS compliance and MSL Level 1 (Unlimited) moisture sensitivity ratings, ensuring equivalent environmental and regulatory qualification for board-level applications.
Output Signal Considerations:
The TSCSHNN150PGUCV operates at 5V supply with 0 mV to 45.75 mV output, compared to the XPC150GTC's 12V supply with 0 mV to 90 mV output. The substitute provides improved accuracy (±0.15% versus ±1%) and extended low-temperature operating range (-40°C versus -25°C minimum). Signal conditioning or amplification may be required in systems designed for the original 90 mV output level.
Supply Voltage Compatibility:
The TSCSHNN150PGUCV supply voltage range (1.5V to 12V) overlaps with the XPC150GTC range (3V to 16V) within the 1.5V to 12V window, supporting direct substitution in systems operating within this common range.
Active Product Status:
Selection of the TSCSHNN150PGUCV ensures ongoing component availability, technical support, and supply chain continuity compared to the obsolete XPC150GTC.
Frequently Asked Questions (FAQ)
Q: Can the TSCSHNN150PGUCV directly replace the XPC150GTC without circuit modifications?
A: Both sensors share identical pressure ratings, vented gauge configuration, Wheatstone Bridge output type, barbed male port connection, and PC pin termination. However, the output signal levels differ (45.75 mV at 5V versus 90 mV at 12V). Direct mechanical and pneumatic replacement is possible; electrical signal conditioning may be required depending on downstream amplifier or ADC input specifications.
Q: What are the key compatibility criteria for pressure sensor substitution?
A: Critical parameters include operating pressure rating, pressure type (vented gauge), output signal type (Wheatstone Bridge), port size and style (male barbed 0.19" tube), supply voltage range overlap, termination style (PC pin), and mounting configuration (through-hole). Both sensors meet these criteria.
Q: How do accuracy specifications differ between these sensors?
A: The XPC150GTC specifies ±1% accuracy, while the TSCSHNN150PGUCV provides ±0.15% accuracy. The substitute offers improved measurement precision. System designs relying on the original ±1% specification will benefit from the tighter tolerance of the substitute.
Q: Are there temperature range differences affecting substitution?
A: The XPC150GTC operates from -25°C to 85°C; the TSCSHNN150PGUCV extends the minimum operating temperature to -40°C. Both share the 85°C maximum. The substitute supports broader low-temperature applications.
Q: What is the significance of the "Side Port" designation in the TSCSHNN150PGUCV package?
A: The TSCSHNN150PGUCV features a side port configuration within the 4-SIP package, compared to the standard 4-SIP module of the XPC150GTC. This affects PCB layout and mounting orientation. Physical board layout verification is necessary to confirm mechanical fit.
Q: Do both sensors maintain equivalent RoHS and MSL compliance?
A: Yes. Both the XPC150GTC and TSCSHNN150PGUCV are RoHS compliant with MSL Level 1 (Unlimited) ratings, ensuring equivalent environmental qualification and regulatory status for board-level deployment.
Q: What supply voltage should be selected for the TSCSHNN150PGUCV substitute?
A: The TSCSHNN150PGUCV operates across 1.5V to 12V supply range. For systems originally designed for 12V operation, 12V supply is compatible. For systems designed for 3V to 16V operation, the substitute functions within the 1.5V to 12V overlap window. Systems requiring supply voltages above 12V require alternative substitutes or external regulation.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts