Request Quote
(Ships tomorrow)
XHP-4-R Equivalent & Substitute Parts
Part Overview
The XHP-4-R is a 4-position rectangular connector housing manufactured by JST Sales America Inc. in the XH series. This receptacle housing accepts female socket contacts with a 0.098" (2.50mm) pitch and is designed for free-hanging in-line mounting applications. The part is actively produced and RoHS compliant, making it suitable for industrial and commercial electronic assemblies where standardized connector interfaces are required.
Substitute parts become necessary when the primary part experiences supply constraints, when specific color or material requirements differ from design specifications, or when alternative series offer enhanced performance characteristics within the same electrical and mechanical envelope.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Connector Type | Receptacle |
| Contact Type | Female Socket |
| Number of Positions | 4 |
| Pitch | 0.098" (2.50mm) |
| Number of Rows | 1 |
| Mounting Type | Free Hanging (In-Line) |
| Contact Termination | Crimp |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution eligibility for the XHP-4-R is determined by strict equivalence across the following parameters: connector type (receptacle), contact type (female socket), number of positions (4), pitch (0.098" / 2.50mm), number of rows (1), mounting type (free hanging in-line), and contact termination method (crimp). All identified substitute parts meet these core electrical and mechanical requirements.
The substitute parts are grouped into two categories based on insulation material composition:
Polyamide (PA6) / Nylon 6 Group: XHP-4-R (JST) operates within -25°C to 85°C with PA6 insulation.
Polyamide (PA66) / Nylon 6/6 and Polybutylene Terephthalate (PBT) Groups: TE Connectivity parts (171822-4, 172142-4, 4-171822-4, 440133-4, 1-1534150-1) utilize PA66 or PBT insulation materials, offering extended operating temperature ranges and alternative performance profiles while maintaining identical pitch, position count, and mounting characteristics.
All substitute parts are RoHS compliant and carry MSL rating of 1 (Unlimited).
Parameter Comparison
| Part Number | Manufacturer | Series | Positions | Pitch | Insulation Material | Color | Operating Temperature | RoHS Status |
|---|---|---|---|---|---|---|---|---|
| XHP-4-R | JST Sales America Inc. | XH | 4 | 0.098" (2.50mm) | Polyamide (PA6), Nylon 6 | Red | -25°C ~ 85°C | RoHS Compliant |
| 1-1534150-1 | TE Connectivity AMP Connectors | Micro Quadlok | 4 | 0.098" (2.50mm) | Polybutylene Terephthalate (PBT), Glass Filled | Black | -40°C ~ 80°C | RoHS Compliant |
| 171822-4 | TE Connectivity AMP Connectors | EI | 4 | 0.098" (2.50mm) | Polyamide (PA66), Nylon 6/6 | Natural | -20°C ~ 95°C | RoHS Compliant |
| 172142-4 | TE Connectivity AMP Connectors | EI | 4 | 0.098" (2.50mm) | Polyamide (PA66), Nylon 6/6 | Natural | -20°C ~ 95°C | ROHS3 Compliant |
| 4-171822-4 | TE Connectivity AMP Connectors | EI | 4 | 0.098" (2.50mm) | Polyamide (PA66), Nylon 6/6 | Blue | -20°C ~ 95°C | RoHS Compliant |
| 440133-4 | TE Connectivity AMP Connectors | High Performance Interconnect (HPI) | 4 | 0.098" (2.50mm) | Polyamide (PA66), Nylon 6/6 | Natural | -25°C ~ 105°C | ROHS3 Compliant |
Engineering Selection Recommendations
All substitute parts maintain active product status and RoHS compliance, ensuring regulatory alignment with the XHP-4-R. Selection among substitutes depends on application-specific requirements:
For standard operating conditions (-25°C to 85°C): 171822-4, 172142-4, 4-171822-4, and 440133-4 are suitable. The 440133-4 (HPI series) extends the upper temperature limit to 105°C, providing margin for thermal stress environments.
For extended low-temperature operation (below -25°C): 1-1534150-1 operates to -40°C, though its upper limit is 80°C.
For REACH compliance requirements: 172142-4 and 440133-4 carry explicit REACH status documentation (REACH Affected and REACH Unaffected, respectively).
For material-specific applications: PA66 insulation (171822-4, 172142-4, 4-171822-4, 440133-4) offers higher thermal stability than PA6. PBT glass-filled insulation (1-1534150-1) provides enhanced mechanical rigidity.
Frequently Asked Questions (FAQ)
Q: Can XHP-4-R be directly replaced with any of the listed substitutes?
A: Yes, all listed parts are parametric equivalents sharing identical connector type, contact type, position count, pitch, row configuration, mounting type, and contact termination. Physical and electrical compatibility is maintained across all substitutes.
Q: What is the significance of insulation material differences?
A: Insulation material affects thermal stability and mechanical properties. PA6 (XHP-4-R) and PA66 (TE EI series) are both polyamides with similar electrical characteristics but different temperature ratings. PBT glass-filled (1-1534150-1) offers superior rigidity and chemical resistance. Material selection should align with application thermal and mechanical requirements.
Q: Are there color restrictions for substitution?
A: Color is a cosmetic parameter and does not affect electrical or mechanical function. XHP-4-R (red), 1-1534150-1 (black), 171822-4 (natural), 172142-4 (natural), 4-171822-4 (blue), and 440133-4 (natural) are interchangeable from a functional standpoint. Color selection may be driven by assembly documentation, traceability, or visual identification requirements.
Q: What operating temperature range should I select?
A: Choose based on application extremes. XHP-4-R operates -25°C to 85°C. For applications exceeding 85°C, select 171822-4, 172142-4, 4-171822-4 (all -20°C to 95°C) or 440133-4 (-25°C to 105°C). For applications below -25°C, 1-1534150-1 (-40°C to 80°C) is required.
Q: Do all parts accept the same contact types?
A: Yes. All parts are receptacle housings designed for female socket contacts with 0.098" (2.50mm) pitch. Contact compatibility is maintained across all substitutes.
Q: What is the difference between RoHS and ROHS3 compliance?
A: Both designations indicate RoHS compliance. ROHS3 refers to compliance with the most recent RoHS directive iteration. Both are acceptable for regulatory purposes; selection depends on customer or regional requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts