Request Quote
(Ships tomorrow)
WR18AT/UCV Equivalent & Substitute Parts
Part Overview
The WR18AT/UCV is a rocker switch manufactured by NKK Switches, classified as SPDT (Single Pole Double Throw) with a momentary-off-momentary (Mom-Off-Mom) switch function. This panel-mount, snap-in component is rated for 15A at 125V AC and 30V DC, featuring a concave black actuator with screw terminal connections and IP67 ingress protection.
The WR18AT/UCV is currently listed as obsolete. Identifying equivalent substitute parts is necessary to maintain system functionality and ensure continued availability for applications requiring this switch specification.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | NKK Switches |
| Series | WR |
| Circuit Configuration | SPDT |
| Switch Function | Mom-Off-Mom |
| Current Rating | 15A (AC/DC) |
| Voltage Rating - AC | 125V |
| Voltage Rating - DC | 30V |
| Mounting Type | Panel Mount, Snap-In |
| Actuator Type | Concave (Curved) |
| Actuator Color | Black |
| Termination Style | Screw Terminal |
| Ingress Protection | IP67 |
| Panel Cutout Dimensions | Rectangular - 34.20mm x 17.20mm |
| Operating Temperature Range | -25°C to 85°C |
| Mechanical Life | 30,000 Cycles |
| Electrical Life | 10,000 Cycles |
| Approval Agencies | EN, UL |
Substitute Part Grouping Explanation
Substitution of the WR18AT/UCV is determined by strict equivalence across electrical and mechanical parameters. The substitute part must maintain identical specifications in the following critical areas:
- Circuit configuration (SPDT)
- Switch function (Mom-Off-Mom)
- Current and voltage ratings (15A AC/DC, 125V AC, 30V DC)
- Mounting type and panel cutout dimensions (Panel Mount, Snap-In; 34.20mm x 17.20mm)
- Actuator type and color (Concave, Black)
- Termination style (Screw Terminal)
- Ingress protection rating (IP67)
- Operating temperature range (-25°C to 85°C)
- Mechanical and electrical life cycles (30,000 and 10,000 respectively)
- Regulatory approvals (EN, UL)
The WR18AT/CUL meets all these criteria and qualifies as a direct substitute.
Parameter Comparison
| Parameter | WR18AT/UCV (Main Part) | WR18AT/CUL (Substitute) |
|---|---|---|
| Manufacturer | NKK Switches | NKK Switches |
| Series | WR | WR |
| Circuit Configuration | SPDT | SPDT |
| Switch Function | Mom-Off-Mom | Mom-Off-Mom |
| Current Rating | 15A (AC/DC) | 15A (AC/DC) |
| Voltage Rating - AC | 125V | 125V |
| Voltage Rating - DC | 30V | 30V |
| Mounting Type | Panel Mount, Snap-In | Panel Mount, Snap-In |
| Actuator Type | Concave (Curved) | Concave (Curved) |
| Actuator Color | Black | Black |
| Termination Style | Screw Terminal | Screw Terminal |
| Ingress Protection | IP67 | IP67 |
| Panel Cutout Dimensions | Rectangular - 34.20mm x 17.20mm | Rectangular - 34.20mm x 17.20mm |
| Operating Temperature Range | -25°C to 85°C | -25°C to 85°C |
| Mechanical Life | 30,000 Cycles | 30,000 Cycles |
| Electrical Life | 10,000 Cycles | 10,000 Cycles |
| Approval Agencies | EN, UL | EN, UL |
| Product Status | Obsolete | Active |
| RoHS Status | Not specified | ROHS3 Compliant |
| REACH Status | Not specified | REACH Unaffected |
Engineering Selection Recommendations
The WR18AT/CUL is the direct substitute for the obsolete WR18AT/UCV. Both parts share identical electrical ratings, mechanical specifications, and regulatory certifications. The WR18AT/CUL maintains active product status and includes ROHS3 compliance and REACH unaffected designation, providing regulatory advantages for new designs and ongoing procurement.
Selection of WR18AT/CUL ensures functional equivalence while supporting current compliance requirements and supply chain continuity.
Frequently Asked Questions (FAQ)
Q: Can WR18AT/CUL be used as a direct replacement for WR18AT/UCV?
A: Yes. Both parts are electrically and mechanically identical across all specified parameters, including circuit configuration, current and voltage ratings, mounting dimensions, and regulatory approvals.
Q: What is the difference between WR18AT/UCV and WR18AT/CUL?
A: The primary difference is product status. WR18AT/UCV is obsolete, while WR18AT/CUL is active. WR18AT/CUL additionally carries ROHS3 compliance and REACH unaffected designation. All functional and electrical specifications remain identical.
Q: Are the panel cutout dimensions identical?
A: Yes. Both parts require a rectangular panel cutout of 34.20mm x 17.20mm and use identical snap-in mounting.
Q: Do both parts have the same termination style?
A: Yes. Both parts use screw terminal connections.
Q: What regulatory approvals apply to both parts?
A: Both WR18AT/UCV and WR18AT/CUL carry EN and UL approvals.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts