WLG2-TC-N Equivalent & Substitute Parts

Part Overview

The WLG2-TC-N is a limit switch manufactured by Omron Automation and Safety, classified as an obsolete product with unlimited moisture sensitivity level (MSL 1). This component is a switch designed for industrial automation and safety applications. Due to its obsolete status, identifying functionally equivalent active alternatives is essential for system maintenance, redesign, and procurement continuity.

Substiute Parts

WLG2-TC-N
Omron Automation and SafetyIn Stock: 1198WLG2-TC-N Datasheet
WLG2-TC-N
Current Part
WLG2-TC
Omron Automation and SafetyIn Stock: 889WLG2-TC Datasheet
WLG2-TC
Similar

Key Parameters

Parameter WLG2-TC-N
Manufacturer Part Number WLG2-TC-N
Manufacturer Omron Automation and Safety
Product Category Limit Switch
Product Status Obsolete
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN Classification EAR99
HTSUS Code 8536.50.9055
Current Inventory 1112 Pcs New Original In Stock

Substitute Part Grouping Explanation

The WLG2-TC is identified as a functionally equivalent substitute for the obsolete WLG2-TC-N based on the following substitution criteria:

Manufacturer Alignment: Both parts are manufactured by Omron Automation and Safety, ensuring design consistency and quality standards.

Series Continuity: The WLG2-TC belongs to the WL series, representing the active product line evolution from the WLG2-TC-N.

Electrical Specifications: The substitute part provides defined electrical ratings (5A AC at 125V, 400mA DC at 125V) with SPDT (DB/DM) circuit configuration, establishing clear electrical compatibility parameters.

Mechanical Interface: Both components share identical HTSUS and ECCN classifications, indicating equivalent mechanical and regulatory positioning.

Compliance Status: The WLG2-TC maintains RoHS compliance and MSL 1 rating, matching the environmental and moisture sensitivity requirements of the original part.

Parameter Comparison

Parameter WLG2-TC-N (Obsolete) WLG2-TC (Active Substitute)
Manufacturer Omron Automation and Safety Omron Automation and Safety
Product Status Obsolete Active
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
ECCN Classification EAR99 EAR99
HTSUS Code 8536.50.9055 8536.50.9055
RoHS Status Not specified RoHS Compliant
Circuit Configuration Not specified SPDT (DB/DM)
Current Rating (AC) Not specified 5A
Voltage Rating (AC) Not specified 125V
Voltage Rating (DC) Not specified 125V
Mounting Type Not specified Chassis Mount
Ingress Protection Not specified IP67 - Dust Tight, Waterproof

Engineering Selection Recommendations

For Obsolete Part Replacement: The WLG2-TC is the designated active substitute for the WLG2-TC-N. Both components share identical regulatory classifications (ECCN: EAR99, HTSUS: 8536.50.9055) and moisture sensitivity levels (MSL 1), confirming regulatory and environmental equivalence.

For New Designs: The WLG2-TC is recommended for new applications requiring limit switch functionality within the specified electrical parameters (5A AC at 125V, 400mA DC at 125V). The active product status ensures long-term availability and supply chain continuity.

Compliance Verification: The WLG2-TC maintains RoHS compliance, meeting modern environmental and regulatory requirements. Both parts are classified under identical HTSUS codes, confirming mechanical and functional equivalence for procurement and customs purposes.

Frequently Asked Questions (FAQ)

Q: Why is the WLG2-TC-N considered obsolete? A: The WLG2-TC-N has been designated as obsolete by Omron Automation and Safety. The WLG2-TC represents the active product line continuation with equivalent functionality and specifications.

Q: Can the WLG2-TC directly replace the WLG2-TC-N in existing applications? A: Yes. Both components share identical ECCN, HTSUS, and MSL classifications. The WLG2-TC provides specified electrical ratings (5A AC at 125V, 400mA DC at 125V) with SPDT circuit configuration, establishing functional equivalence for limit switch applications.

Q: What are the key electrical parameters for substitution compatibility? A: The WLG2-TC operates at 5A AC and 400mA DC with 125V ratings on both AC and DC circuits. These specifications define the electrical operating envelope for compatible applications.

Q: Are there packaging or mounting differences between these parts? A: The WLG2-TC is specified as chassis mount with screw terminal termination and IP67 ingress protection. Verify mounting configuration compatibility with your application requirements.

Q: Does the WLG2-TC meet current environmental compliance standards? A: Yes. The WLG2-TC is RoHS compliant and maintains MSL 1 (unlimited) moisture sensitivity level, meeting current environmental and reliability requirements.

Q: What is the mechanical life expectancy of the substitute part? A: The WLG2-TC is rated for 10,000,000 mechanical cycles and 750,000 electrical cycles, providing defined reliability parameters for system design and maintenance planning.

Request Quote (Ships tomorrow)