The WLCA2-G is an Omron Automation and Safety snap action switch with SPDT (DB/DM) circuit configuration, rated for 10A at 125V AC and 6A at 30V DC. This component features a side rotary roller actuator with chassis mount termination and IP67 ingress protection. The WLCA2-G is classified as obsolete product status. Identifying equivalent substitute parts is necessary to maintain design continuity and ensure component availability for new production runs and field replacements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | WLCA2-G |
| Manufacturer | Omron Automation and Safety |
| Series | WL |
| Circuit Configuration | SPDT (DB/DM) |
| Switch Function | On-Mom |
| Current Rating (AC) | 10A |
| Current Rating (DC) | 6A |
| Voltage Rating (AC) | 125V |
| Voltage Rating (DC) | 30V |
| Actuator Type | Side Rotary, Roller |
| Mounting Type | Chassis Mount |
| Termination Style | Screw Terminal |
| Ingress Protection | IP67 - Dust Tight, Waterproof |
| Operating Temperature Range | -10°C to 80°C |
| Electrical Life | 750,000 Cycles |
| Mechanical Life | 15,000,000 Cycles |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution eligibility for the WLCA2-G is determined by strict equivalence across the following critical parameters:
- Circuit configuration: SPDT (DB/DM)
- Switch function: On-Mom
- Current rating: 10A AC / 6A DC minimum
- Voltage rating: 125V AC / 30V DC minimum
- Actuator type: Side Rotary, Roller
- Mounting type: Chassis Mount
- Termination style: Screw Terminal
- Ingress protection: IP67 or equivalent
- Operating temperature range: -10°C to 80°C or broader
- Electrical life: 750,000 cycles minimum
- Mechanical life: 15,000,000 cycles minimum
The WLCA2-G-N meets all substitution criteria and is classified as an active product within the WL-N series, providing design continuity with improved product status and compliance certification.
Parameter Comparison
| Parameter | WLCA2-G (Main Part) | WLCA2-G-N (Substitute) |
|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety |
| Circuit Configuration | SPDT (DB/DM) | SPDT (DB/DM) |
| Switch Function | On-Mom | On-Mom |
| Current Rating (AC) | 10A | 10A |
| Current Rating (DC) | 6A | 6A |
| Voltage Rating (AC) | 125V | 125V |
| Voltage Rating (DC) | 30V | 30V |
| Actuator Type | Side Rotary, Roller | Side Rotary, Roller |
| Mounting Type | Chassis Mount | Chassis Mount |
| Termination Style | Screw Terminal | Screw Terminal |
| Ingress Protection | IP67 - Dust Tight, Waterproof | IP67 - Dust Tight, Waterproof |
| Operating Temperature Range | -10°C to 80°C | -10°C to 80°C |
| Electrical Life | 750,000 Cycles | 750,000 Cycles |
| Mechanical Life | 15,000,000 Cycles | 15,000,000 Cycles |
| Product Status | Obsolete | Active |
| RoHS Status | Vendor Undefined | RoHS Compliant |
Engineering Selection Recommendations
The WLCA2-G-N is the direct substitute for the obsolete WLCA2-G. Both components share identical electrical and mechanical specifications across all critical parameters. The WLCA2-G-N provides the following advantages:
- Active product status ensures ongoing manufacturer support and availability
- RoHS compliance certification meets current regulatory requirements
- Identical performance characteristics maintain design compatibility
- Bulk packaging option supports production scalability
Selection of the WLCA2-G-N eliminates obsolescence risk while maintaining full functional and electrical equivalence to the original WLCA2-G specification.
Frequently Asked Questions (FAQ)
Q: Can the WLCA2-G-N be used as a direct replacement for the WLCA2-G?
A: Yes. The WLCA2-G-N meets all electrical and mechanical specifications of the WLCA2-G, including circuit configuration, current and voltage ratings, actuator type, mounting configuration, and operational life cycles. Both components are electrically and mechanically interchangeable.
Q: What is the primary difference between the WLCA2-G and WLCA2-G-N?
A: The WLCA2-G-N is an active product with RoHS compliance certification, while the WLCA2-G is classified as obsolete. The WLCA2-G-N also features a release force specification of 120gf compared to 227gf on the WLCA2-G, and an overtravel specification of 70° compared to 30° on the WLCA2-G. These mechanical differences do not affect substitution eligibility for standard applications.
Q: Are there packaging differences between these parts?
A: The WLCA2-G is supplied with unspecified packaging, while the WLCA2-G-N is available in bulk packaging. Packaging selection should be based on production volume and inventory management requirements.
Q: Does the WLCA2-G-N maintain the same IP67 ingress protection rating?
A: Yes. Both the WLCA2-G and WLCA2-G-N maintain IP67 ingress protection classification, providing dust-tight and waterproof performance across the specified operating temperature range of -10°C to 80°C.
Q: What is the ECCN classification for these components?
A: Both the WLCA2-G and WLCA2-G-N are classified under ECCN EAR99 and HTSUS 8536.50.9055.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts