Request Quote
(Ships tomorrow)
WLCA12-G Equivalent & Substitute Parts
Part Overview
The WLCA12-G is an Omron Automation and Safety snap action switch with SPDT (DB/DM) circuit configuration, rated for 10A at 125V AC and 6A at 30V DC. This component features a side rotary adjustable roller actuator with chassis mount termination and IP67 ingress protection. The WLCA12-G is classified as obsolete, making identification of functionally equivalent alternatives necessary for ongoing system maintenance and new design implementations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | WLCA12-G |
| Manufacturer | Omron Automation and Safety |
| Series | WL |
| Circuit Configuration | SPDT (DB/DM) |
| Switch Function | On-Mom |
| Current Rating (AC) | 10A |
| Current Rating (DC) | 6A |
| Voltage Rating (AC) | 125V |
| Voltage Rating (DC) | 30V |
| Actuator Type | Side Rotary, Adjustable Roller |
| Mounting Type | Chassis Mount |
| Termination Style | Screw Terminal |
| Ingress Protection | IP67 - Dust Tight, Waterproof |
| Operating Temperature Range | -10°C to 80°C |
| Electrical Life | 750,000 Cycles |
| Mechanical Life | 15,000,000 Cycles |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution eligibility for the WLCA12-G is determined by strict equivalence across the following critical parameters:
- Circuit configuration: SPDT (DB/DM)
- Switch function: On-Mom
- Current ratings: 10A AC / 6A DC minimum
- Voltage ratings: 125V AC / 30V DC minimum
- Actuator type: Side Rotary, Adjustable Roller
- Mounting type: Chassis Mount
- Termination style: Screw Terminal
- Ingress protection: IP67 minimum
- Operating temperature range: -10°C to 80°C minimum
- Electrical life: 750,000 cycles minimum
- Mechanical life: 15,000,000 cycles minimum
The WLCA12-G-N meets all substitution criteria and is classified as an active product within the Omron WL series family.
Parameter Comparison
| Parameter | WLCA12-G (Main Part) | WLCA12-G-N (Substitute) | Compatibility |
|---|---|---|---|
| Manufacturer Part Number | WLCA12-G | WLCA12-G-N | Direct Substitute |
| Series | WL | WL-N | Compatible Family |
| Circuit Configuration | SPDT (DB/DM) | SPDT (DB/DM) | Identical |
| Switch Function | On-Mom | On-Mom | Identical |
| Current Rating (AC) | 10A | 10A | Identical |
| Current Rating (DC) | 6A | 6A | Identical |
| Voltage Rating (AC) | 125V | 125V | Identical |
| Voltage Rating (DC) | 30V | 30V | Identical |
| Actuator Type | Side Rotary, Adjustable Roller | Side Rotary, Adjustable Roller | Identical |
| Mounting Type | Chassis Mount | Chassis Mount | Identical |
| Termination Style | Screw Terminal | Screw Terminal | Identical |
| Ingress Protection | IP67 - Dust Tight, Waterproof | IP67 - Dust Tight, Waterproof | Identical |
| Operating Temperature Range | -10°C to 80°C | -10°C to 80°C | Identical |
| Electrical Life | 750,000 Cycles | 750,000 Cycles | Identical |
| Mechanical Life | 15,000,000 Cycles | 15,000,000 Cycles | Identical |
| Product Status | Obsolete | Active | Upgrade Available |
| Packaging | - | Bulk | Different |
| RoHS Status | Vendor Undefined | RoHS Compliant | Improved Compliance |
Engineering Selection Recommendations
The WLCA12-G-N is the direct functional equivalent for the obsolete WLCA12-G. All electrical and mechanical parameters are identical, ensuring drop-in compatibility in existing circuit designs and applications. The WLCA12-G-N offers the additional advantage of active product status, ensuring continued availability and supply chain reliability. The WLCA12-G-N carries RoHS compliance certification, whereas the original part's compliance status is undefined, providing improved regulatory alignment for new designs and system upgrades.
Frequently Asked Questions (FAQ)
Q: Can WLCA12-G-N replace WLCA12-G in existing applications?
A: Yes. The WLCA12-G-N provides identical electrical ratings (10A AC at 125V, 6A DC at 30V), mechanical specifications (15,000,000 cycle life), and physical form factor (chassis mount, screw terminal, IP67 protection). No circuit modifications are required.
Q: What are the differences between WLCA12-G and WLCA12-G-N?
A: The primary differences are product status (obsolete versus active), packaging format (undefined versus bulk), and RoHS compliance certification (undefined versus compliant). Electrical and mechanical performance parameters are identical.
Q: Why is the WLCA12-G classified as obsolete?
A: The WLCA12-G has been superseded by the WLCA12-G-N within the Omron product portfolio. The newer variant maintains full functional equivalence while offering improved compliance and supply chain continuity.
Q: Are there packaging considerations when switching from WLCA12-G to WLCA12-G-N?
A: The WLCA12-G-N is supplied in bulk packaging, whereas the original part's packaging format is not specified. Verify bulk packaging compatibility with your procurement and storage requirements.
Q: Does the WLCA12-G-N meet RoHS requirements?
A: Yes. The WLCA12-G-N is RoHS compliant. If RoHS compliance is a system requirement, the WLCA12-G-N satisfies this criterion, whereas the original part's compliance status is undefined.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts