Equivalent & Substitute Parts Reference for VWRAS2-D24-D9-SIP

Part Overview

The VWRAS2-D24-D9-SIP by CUI Inc. is an isolated module DC-DC converter featuring dual outputs of +9V and -9V, each rated at 111mA, with an input range of 18V to 36V. The module delivers 2W of power with 1.5kV isolation and offers short-circuit protection (SCP), designed primarily for ITE (Commercial) applications. It is packaged as an 8-SIP Module with 7 leads, measures 22.0mm x 9.5mm x 12.0mm, supports through-hole mounting, and is RoHS compliant. The VWRAS2-D24-D9-SIP is classified as Obsolete, necessitating identification of equivalent and substitute DC-DC converters with matching electrical and mechanical parameters for continued support in existing designs.

Substiute Parts

VWRAS2-D24-D9-SIP
CUI Inc.In Stock: 695VWRAS2-D24-D9-SIP Datasheet
VWRAS2-D24-D9-SIP
Current Part
RS-2409D/H2
Recom PowerIn Stock: 687RS-2409D/H2 Datasheet
RS-2409D/H2
Direct

Key Parameters

ParameterValue
Manufacturer Part NumberVWRAS2-D24-D9-SIP
ManufacturerCUI Inc.
DescriptionDC DC CONVERTER +/-9V 2W
TypeIsolated Module
Number of Outputs2
Voltage - Input (Min)18V
Voltage - Input (Max)36V
Voltage - Output 19V
Voltage - Output 2-9V
Current - Output (Max)111mA, 111mA
Power (Watts)2 W
Voltage - Isolation1.5 kV
ApplicationsITE (Commercial)
FeaturesSCP
Operating Temperature-40°C ~ 85°C
Efficiency78%
Mounting TypeThrough Hole
Package / Case8-SIP Module, 7 Leads
Size / Dimension22.0mm x 9.5mm x 12.0mm
RoHS StatusRoHS Compliant
Product StatusObsolete

Substitute Part Grouping Explanation

Substitute parts for the VWRAS2-D24-D9-SIP are identified based solely on matching parameters critical for DC-DC converter selection. These parameters include input voltage range (18V – 36V), dual output voltages (+9V, -9V), maximum output currents (111mA per channel), total output power (2W), isolation voltage, packaging (8-SIP Module, 7 leads), mounting type (Through Hole), operating temperature range (-40°C ~ 85°C), RoHS compliance, and application suitability (ITE/commercial). Only products meeting all these criteria are considered valid, direct substitutes.

Key matching parameters:

  • Input voltage range
  • Output voltages and currents
  • Isolation voltage
  • Package style and dimensions
  • Mounting method
  • Operating temperature range
  • Regulatory compliance and product status

Parameter Comparison

Parameter Main Part: VWRAS2-D24-D9-SIP
CUI Inc.
Substitute: RS-2409D/H2
Recom Power
DescriptionDC DC CONVERTER +/-9V 2WDC DC CONVERTER +/-9V 2W
TypeIsolated ModuleIsolated Module
Number of Outputs22
Voltage - Input (Min)18V18V
Voltage - Input (Max)36V36V
Voltage - Output 19V9V
Voltage - Output 2-9V-9V
Current - Output (Max)111mA, 111mA111mA, 111mA
Power (Watts)2 W2 W
Voltage - Isolation1.5 kV2 kV
ApplicationsITE (Commercial)ITE (Commercial), Medical
FeaturesSCPRemote On/Off, SCP
Operating Temperature-40°C ~ 85°C-40°C ~ 85°C
Efficiency78%81%
Mounting TypeThrough HoleThrough Hole
Package / Case8-SIP Module, 7 Leads8-SIP Module, 7 Leads
Size / Dimension22.0mm x 9.5mm x 12.0mm21.8mm x 9.2mm x 11.1mm
RoHS StatusRoHS CompliantROHS3 Compliant
Product StatusObsoleteActive

Engineering Selection Recommendations

The main part, VWRAS2-D24-D9-SIP, is classified as Obsolete and RoHS compliant. Substitute RS-2409D/H2 by Recom Power meets all key electrical, mechanical, operating, and compliance parameters, and is Active in production, with ROHS3 and REACH compliance status. For continued applications requiring direct replacement of the VWRAS2-D24-D9-SIP, RS-2409D/H2 provides a compatible solution under the specified certification and compliance constraints.

Frequently Asked Questions (FAQ)

Q1: What are the most important criteria for selecting a substitute for VWRAS2-D24-D9-SIP?
A1: Substitute selection must be based on matching input voltage range, output voltages and currents, isolation voltage, operating temperature, package type and size, mounting method, and compliance status.

Q2: Is RS-2409D/H2 compatible with the mechanical footprint of the VWRAS2-D24-D9-SIP?
A2: RS-2409D/H2 employs the same 8-SIP Module, 7 Lead package and through-hole mounting as VWRAS2-D24-D9-SIP, with closely matched dimensions.

Q3: Does the substitute part meet RoHS and REACH compliance requirements?
A3: RS-2409D/H2 is ROHS3 Compliant and REACH Unaffected, meeting regulatory requirements present in the original part.

Q4: Can this substitute support the same output loads as the original part?
A4: The RS-2409D/H2 supports dual outputs of 9V and -9V at 111mA each, identical to the original part specification.

Q5: Are there any functional features in RS-2409D/H2 not present in VWRAS2-D24-D9-SIP?
A5: RS-2409D/H2 adds Remote On/Off control and is specified for additional Medical application suitability, while maintaining SCP (Short Circuit Protection) present in the original.

Q6: What should be considered regarding operating environmental limits?
A6: Both VWRAS2-D24-D9-SIP and RS-2409D/H2 are specified for -40°C to +85°C operating temperature. No discrepancy exists for environmental compatibility.

Request Quote (Ships tomorrow)