Request Quote
(Ships tomorrow)
VTO70-14IO7 Equivalent & Substitute Parts
Part Overview
The VTO70-14IO7 is a 3-phase bridge SCR module manufactured by IXYS, rated for 1.4 kV off-state voltage with 70 A on-state current capability. This module integrates six SCRs in a bridge configuration with chassis mount FO-T-A packaging. The product is currently obsolete, making identification of functionally equivalent alternatives essential for system maintenance and component sourcing.
Substiute Parts
Key Parameters
| Parameter | VTO70-14IO7 |
|---|---|
| Voltage - Off State | 1.4 kV |
| Current - On State (It (AV)) (Max) | 70 A |
| Voltage - Gate Trigger (Vgt) (Max) | 1.5 V |
| Current - Gate Trigger (Igt) (Max) | 100 mA |
| Current - Non Rep. Surge 50, 60Hz (Itsm) | 550A, 600A |
| Current - Hold (Ih) (Max) | 200 mA |
| Operating Temperature Range | -40°C ~ 125°C (TJ) |
| Mounting Type | Chassis Mount |
| Package / Case | FO-T-A |
| Structure | Bridge, 3-Phase - All SCRs |
| Number of SCRs | 6 SCRs |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution of the VTO70-14IO7 is constrained by the following critical parameters:
Voltage Rating Compatibility: The substitute must maintain the 1.4 kV off-state voltage specification to ensure safe operation within the original circuit design.
Gate Trigger Characteristics: Gate trigger voltage (Vgt) and current (Igt) must remain at or below 1.5 V and 100 mA respectively to maintain compatibility with existing gate drive circuitry.
Operating Temperature Range: The substitute must support the full -40°C to 125°C junction temperature range.
Mounting Configuration: Chassis mount capability is required for mechanical integration.
Current Handling: While the VTO70-14IO7 specifies 70 A on-state current, substitutes with lower on-state current ratings may be acceptable depending on circuit duty cycle and thermal management design.
The MCC26-14IO1B meets the voltage, gate trigger, temperature, and mounting requirements. However, its series-connected SCR structure and reduced on-state current rating (50 A RMS) represent a functional trade-off that requires circuit-level evaluation.
Parameter Comparison
| Parameter | VTO70-14IO7 | MCC26-14IO1B |
|---|---|---|
| Voltage - Off State | 1.4 kV | 1.4 kV |
| Voltage - Gate Trigger (Vgt) (Max) | 1.5 V | 1.5 V |
| Current - Gate Trigger (Igt) (Max) | 100 mA | 100 mA |
| Current - Hold (Ih) (Max) | 200 mA | 200 mA |
| Operating Temperature Range | -40°C ~ 125°C (TJ) | -40°C ~ 125°C (TJ) |
| Mounting Type | Chassis Mount | Chassis Mount |
| Current - On State (It (AV)) (Max) | 70 A | 32 A |
| Current - On State (It (RMS)) (Max) | Not specified | 50 A |
| Current - Non Rep. Surge 50, 60Hz (Itsm) | 550A, 600A | 520A, 560A |
| Structure | Bridge, 3-Phase - All SCRs | Series Connection - All SCRs |
| Number of SCRs | 6 SCRs | 2 SCRs |
| Package / Case | FO-T-A | TO-240AA |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
The MCC26-14IO1B is an active product with equivalent voltage and gate trigger specifications, making it suitable for applications where the reduced on-state current rating aligns with circuit requirements. The MCC26-14IO1B carries RoHS3 compliance, providing regulatory advantage over the obsolete VTO70-14IO7.
The structural difference—series-connected SCRs versus bridge configuration—requires circuit-level analysis to confirm functional equivalence. Applications operating at or below 50 A RMS current may transition directly to the MCC26-14IO1B. Applications requiring sustained currents above 50 A RMS necessitate alternative sourcing strategies or circuit redesign.
Both parts maintain identical operating temperature ranges and hold current specifications, supporting thermal and control circuit compatibility.
Frequently Asked Questions (FAQ)
Q: Can the MCC26-14IO1B directly replace the VTO70-14IO7 in all applications?
A: Direct replacement is possible only when circuit current requirements do not exceed 50 A RMS. The MCC26-14IO1B's series-connected SCR structure differs from the VTO70-14IO7 bridge configuration, requiring verification that the application topology is compatible with this structural change.
Q: What is the significance of the different package types (FO-T-A versus TO-240AA)?
A: Both packages support chassis mount installation. The TO-240AA package used by the MCC26-14IO1B is a standard industry format with broader availability. Mechanical mounting hole patterns and thermal interface requirements must be evaluated for each application.
Q: Are the gate drive requirements identical between these parts?
A: Yes. Both parts specify 1.5 V maximum gate trigger voltage and 100 mA maximum gate trigger current, ensuring compatibility with existing gate drive circuits.
Q: Why does the MCC26-14IO1B have lower on-state current than the VTO70-14IO7?
A: The MCC26-14IO1B uses a series-connected SCR topology optimized for different application requirements. This structural difference results in different current handling characteristics. Circuit duty cycle, thermal management, and load characteristics determine whether this rating difference impacts system performance.
Q: What compliance advantages does the MCC26-14IO1B offer?
A: The MCC26-14IO1B is RoHS3 compliant and carries active product status, providing regulatory support and ongoing manufacturer support. The VTO70-14IO7 is obsolete, limiting future availability and technical support.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts