VR05S12 DC DC Converter Equivalent & Substitute Parts

Part Overview

The VR05S12 is an active linear regulator replacement DC DC converter manufactured by XP Power, designed for commercial ITE applications. This single-output module converts input voltages between 15V and 36V to a regulated 12V output at 500mA maximum current. The component is packaged in a 3-SIP module format with through-hole mounting and operates across an extended temperature range of -40°C to 85°C with derating. The VR05S12 is actively produced and stocked, with 1084 units available in inventory. Equivalent and substitute parts are identified based on matching electrical specifications, mechanical compatibility, and functional performance characteristics to support component procurement flexibility and supply chain continuity.

Substiute Parts

VR05S12
XP PowerIn Stock: 1139VR05S12 Datasheet
VR05S12
Current Part
K7812-500R3
Mornsun America, LLCIn Stock: 2776K7812-500R3 Datasheet
K7812-500R3
Similar

Key Parameters

Parameter Specification
Voltage - Input (Min) 15V
Voltage - Input (Max) 36V
Voltage - Output 12V
Current - Output (Max) 500mA
Efficiency 94%
Operating Temperature Range -40°C to 85°C (With Derating)
Mounting Type Through Hole
Package / Case 3-SIP Module
Size / Dimension 0.46" L x 0.30" W x 0.40" H (11.6mm x 7.6mm x 10.2mm)
Type Linear Regulator Replacement
Number of Outputs 1
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the VR05S12 are identified based on strict electrical and mechanical parameter matching within the linear regulator replacement DC DC converter category. The substitution criteria are established through the following key parameters:

Electrical Compatibility Parameters:

  • Output voltage specification of 12V
  • Maximum output current rating of 500mA
  • Operating temperature range of -40°C to 85°C with derating
  • Efficiency rating of 94%
  • Input voltage range compatibility with 15V to 36V operation

Mechanical Compatibility Parameters:

  • Through-hole mounting type
  • 3-SIP module package format
  • Physical dimensions of 0.46" L x 0.30" W x 0.40" H (11.6mm x 7.6mm x 10.2mm)

Functional Classification:

  • Linear regulator replacement topology
  • Single output configuration
  • Commercial ITE application suitability

Parts meeting all specified electrical and mechanical parameters are classified as direct substitutes. The K7812-500R3 manufactured by Mornsun America, LLC satisfies these substitution criteria through matching output specifications, current ratings, temperature performance, efficiency, mounting configuration, and physical package dimensions.

Parameter Comparison

Parameter VR05S12 (XP Power) K7812-500R3 (Mornsun America, LLC)
Voltage - Input (Min) 15V 8V, 15V
Voltage - Input (Max) 36V 24V, 36V
Voltage - Output 12V 12V
Current - Output (Max) 500mA 500mA
Efficiency 94% 94%
Operating Temperature Range -40°C to 85°C (With Derating) -40°C to 85°C (With Derating)
Mounting Type Through Hole Through Hole
Package / Case 3-SIP Module 3-SIP Module
Size / Dimension 0.46" L x 0.30" W x 0.40" H (11.6mm x 7.6mm x 10.2mm) 0.46" L x 0.30" W x 0.40" H (11.6mm x 7.6mm x 10.2mm)
Type Linear Regulator Replacement Linear Regulator Replacement
Number of Outputs 1 1
RoHS Status ROHS3 Compliant RoHS Compliant
Product Status Active Active

Engineering Selection Recommendations

Both the VR05S12 and K7812-500R3 are active products with current manufacturing status and established supply availability. The VR05S12 carries ROHS3 compliance certification, while the K7812-500R3 holds RoHS compliance with additional regulatory approvals including CB, CE, and cURus certifications. The K7812-500R3 includes SCP (Short Circuit Protection) as an integrated feature and carries REACH Unaffected status with MSL 1 (Unlimited) moisture sensitivity rating.

Selection between these parts is determined by specific application requirements regarding regulatory certifications and protection features. The K7812-500R3 provides broader input voltage flexibility with 8V minimum input option in addition to the standard 15V minimum, and offers additional safety certifications suitable for applications requiring CB, CE, or cURus approval pathways. Both parts deliver identical electrical performance in 12V, 500mA output specifications and maintain equivalent thermal and efficiency characteristics across the specified operating range.

Frequently Asked Questions (FAQ)

Q: Can the K7812-500R3 directly replace the VR05S12 in existing circuit board designs?

A: Yes. Both parts share identical output voltage (12V), maximum output current (500mA), operating temperature range (-40°C to 85°C with derating), efficiency (94%), mounting type (through-hole), package format (3-SIP module), and physical dimensions (0.46" L x 0.30" W x 0.40" H). Direct PCB substitution is supported without layout modifications.

Q: What are the input voltage differences between these parts?

A: The VR05S12 operates with input voltage range of 15V to 36V. The K7812-500R3 offers extended input flexibility with options for 8V to 24V or 15V to 36V configurations. For applications requiring 15V to 36V input operation, both parts are functionally equivalent.

Q: Are there regulatory compliance differences between the VR05S12 and K7812-500R3?

A: The VR05S12 carries ROHS3 compliance. The K7812-500R3 holds RoHS compliance with additional certifications including CB, CE, and cURus approvals. Applications requiring specific regulatory certifications should reference the appropriate part based on compliance pathway requirements.

Q: Does the K7812-500R3 include additional protection features?

A: The K7812-500R3 integrates SCP (Short Circuit Protection) as a standard feature. The VR05S12 specifications do not list this protection feature. Applications requiring integrated short circuit protection benefit from K7812-500R3 selection.

Q: Are the physical package dimensions identical?

A: Yes. Both the VR05S12 and K7812-500R3 are packaged in 3-SIP module format with identical dimensions of 0.46" L x 0.30" W x 0.40" H (11.6mm x 7.6mm x 10.2mm), supporting direct mechanical interchangeability in through-hole PCB applications.

Q: What is the moisture sensitivity rating difference?

A: The VR05S12 lists MSL as Not Applicable. The K7812-500R3 carries MSL 1 (Unlimited) rating, indicating no moisture sensitivity restrictions for storage and handling.

Request Quote (Ships tomorrow)