Equivalent & Substitute Parts for VOF-6-15

Part Overview

The VOF-6-15 from CUI Inc. is an open frame AC/DC converter with a single 15V output at 400mA (6W maximum) designed for ITE (Commercial) applications. This model features universal AC/DC input (85 ~ 264 VAC, 120 ~ 375 VDC), through hole mounting, 4-DIP Module package, and regulatory certifications including CB Scheme, EN, IEC, SIQ, TUV, and UL. The VOF-6-15 is designated as obsolete. Due to its obsolete status, it is necessary to identify alternative models with directly compatible electrical and mechanical characteristics.

Substiute Parts

VOF-6-15
CUI Inc.In Stock: 1152VOF-6-15 Datasheet
VOF-6-15
Current Part
PSK-10D-15
CUI Inc.In Stock: 825PSK-10D-15 Datasheet
PSK-10D-15
MFR Recommended
VOF-6B-S15
CUI Inc.In Stock: 1248VOF-6B-S15 Datasheet
VOF-6B-S15
MFR Recommended

Key Parameters

Manufacturer Part Number Type Output Voltage Output Current (Max) Power (Watts) Number of Outputs Input Voltage Range Mounting Type Package / Case Efficiency Operating Temperature Approval Agency Standard Number Line Regulation Load Regulation RoHS Status
VOF-6-15 Open Frame 15V 400mA 6 W 1 85 ~ 264 VAC, 120 ~ 375 VDC Through Hole 4-DIP Module 78% 0°C ~ 60°C (With Derating) CB Scheme, EN, IEC, SIQ, TUV, UL 55024; 60950-1; 61000-3-2; 61000-3-3 ±0.5% ±1% RoHS Compliant

Substitute Part Grouping Explanation

Substitution is based strictly on matching the primary electrical and mechanical parameters required for AC/DC converter selection. The key parameters are:

  • Output Voltage: 15V
  • Output Current (Max): ≥400mA
  • Power (Watts): ≥6W
  • Input Voltage Range: Must support universal input
  • Number of Outputs: 1
  • Mounting Type and Package / Case: Through Hole, matching or compatible DIP module
  • Regulatory Compliance: Must have suitable approvals
  • Efficiency: Comparable or higher
  • RoHS Status: Compliant

Parameter Comparison

Manufacturer Part Number Type Output Voltage Output Current (Max) Power (Watts) Number of Outputs Input Voltage Range Mounting Type Package / Case Efficiency Operating Temperature Approval Agency Standard Number Line Regulation Load Regulation RoHS Status
VOF-6-15 Open Frame 15V 400mA 6 W 1 85 ~ 264 VAC, 120 ~ 375 VDC Through Hole 4-DIP Module 78% 0°C ~ 60°C CB Scheme, EN, IEC, SIQ, TUV, UL 55024; 60950-1; 61000-3-2; 61000-3-3 ±0.5% ±1% RoHS Compliant
PSK-10D-15 Enclosed 15V 660mA 10 W 1 85 ~ 305 VAC, 100 ~ 430 VDC Through Hole 6-DIP Module, 4 Leads 84% -40°C ~ 85°C CE, cURus 60335-1; 62368-1 ±0.5% ±1% ROHS3 Compliant
VOF-6B-S15 Open Frame 15V 400mA 6 W 1 85 ~ 264 VAC Through Hole 4-DIP Module 79.03% -25°C ~ 70°C CB Scheme, EN, FCC, IEC, UL 60950-1; 61000-3-2; 61000-3-3; 62368-1 ±1% ±3% RoHS Compliant

Engineering Selection Recommendations

  • The VOF-6-15 is obsolete. Both PSK-10D-15 and VOF-6B-S15 are listed with active product status.
  • All substitute listed options are RoHS compliant and have documented agency approvals; each substitute details its supported standards.
  • For direct replacement, select a substitute with matching electrical output (15V, 400mA or higher, single output) and mechanical compatibility (Through Hole mounting, compatible DIP package).
  • Confirm that required regulatory approvals and compliance match end-application requirements as indicated in the provided parameters.

Frequently Asked Questions (FAQ)

Q: Which key parameters must match when selecting a substitute for the VOF-6-15?
A: Substitute parts must match in output voltage (15V), output current (minimum 400mA), number of outputs (1), input voltage range (universal AC input), and mounting/package compatibility. RoHS compliance and appropriate agency approvals must also be present.

Q: Are there differences in mechanical package between the VOF-6-15 and its substitutes?
A: The VOF-6-15 and VOF-6B-S15 both use a 4-DIP Module through hole package. The PSK-10D-15 uses a 6-DIP Module, 4 Leads, which should be verified for mechanical compatibility within existing footprints.

Q: Can substitutes be used directly in critical applications requiring the same certifications?
A: Substitute parts provide details of approval agencies and referenced standards. Match these against application requirements based strictly on the provided standard numbers and agencies.

Q: Do all substitutes support a universal input voltage range?
A: All listed substitutes support a universal input voltage range within their specified limits. Verify that these ranges encompass your application's requirements as specified.

Q: Is there any difference in load or line regulation among substitutes?
A: Load and line regulation values are provided for each part. Verify these against application tolerances as specified in the comparison table.

Request Quote (Ships tomorrow)