Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference: VOF-6-12
Part Overview
The VOF-6-12 from CUI Inc. is an open frame AC/DC converter with a single output of 12V at 500mA, rated at 6W, and intended for ITE (Commercial) applications. Its universal input range is 85 ~ 264 VAC or 120 ~ 375 VDC. The product is through-hole mounted in a 4-DIP module package. The VOF-6-12 is classified as Obsolete, necessitating the identification of alternative or replacement models that match key electrical, mechanical, and regulatory parameters for continued design continuity or maintenance purposes.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Voltage - Input | 85 ~ 264 VAC, 120 ~ 375 VDC |
| Voltage - Output 1 | 12V |
| Current - Output (Max) | 500mA |
| Power (Watts) | 6 W |
| Number of Outputs | 1 |
| Mounting Type | Through Hole |
| Package / Case | 4-DIP Module |
| Size / Dimension | 2.16" L x 1.38" W x 0.83" H (54.9mm x 35.0mm x 21.0mm) |
| Efficiency | 77% |
| Operating Temperature | 0°C ~ 60°C (With Derating) |
| Approval Agency | CB Scheme, EN, IEC, SIQ, TUV, UL |
| Standard Number | 55024; 60950-1; 61000-3-2; 61000-3-3 |
| Line Regulation | ±0.5% |
| Load Regulation | ±1% |
| Applications | ITE (Commercial) |
| Type | Open Frame |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitute parts are identified by matching key electrical parameters (input voltage range, output voltage, output current, power rating), mechanical fit (package, dimensions, mounting type), and regulatory compliance (approvals, RoHS). Substitute groupings are limited to models with the same or broader application range, same number of outputs, and supported certification. Only parts with available product status are considered suitable substitutes.
The following key parameters are used for substitution:
- Input voltage range
- Output voltage (12V)
- Output current (≥500mA)
- Power rating (≥6W)
- Output configuration (single output)
- Mounting type (through hole)
- Package / case compatibility
- Regulatory compliance/approval
- RoHS status
Parameter Comparison
| Parameter | Main Part VOF-6-12 |
Substitute 1 VOF-6B-S12 |
Substitute 2 PSK-10D-12 |
|---|---|---|---|
| Voltage - Input | 85 ~ 264 VAC, 120 ~ 375 VDC | 85 ~ 264 VAC, 120 ~ 370 VDC | 85 ~ 305 VAC, 100 ~ 430 VDC |
| Voltage - Output 1 | 12V | 12V | 12V |
| Current - Output (Max) | 500mA | 500mA | 830mA |
| Power (Watts) | 6 W | 6 W | 10 W |
| Number of Outputs | 1 | 1 | 1 |
| Mounting Type | Through Hole | Through Hole | Through Hole |
| Package / Case | 4-DIP Module | 4-DIP Module | 6-DIP Module, 4 Leads |
| Size / Dimension | 2.16" x 1.38" x 0.83" | 1.91" x 0.92" x 0.64" | 1.57" x 1.00" x 0.83" |
| Efficiency | 77% | 79.03% | 84% |
| Operating Temperature | 0°C ~ 60°C (With Derating) | -25°C ~ 70°C (With Derating) | -40°C ~ 85°C (With Derating) |
| Approval Agency | CB Scheme, EN, IEC, SIQ, TUV, UL | CB Scheme, EN, FCC, IEC, UL | CE, cURus |
| Standard Number | 55024; 60950-1; 61000-3-2; 61000-3-3 | 60950-1; 61000-3-2; 61000-3-3; 62368-1 | 60335-1; 62368-1 |
| Line Regulation | ±0.5% | ±1% | ±0.5% |
| Load Regulation | ±1% | ±4% | ±1% |
| Applications | ITE (Commercial) | ITE (Commercial) | Household Appliances, ITE (Commercial) |
| Type | Open Frame | Open Frame | Enclosed |
| RoHS Status | RoHS Compliant | ROHS3 Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
- The VOF-6-12 is classified as Obsolete. Both VOF-6B-S12 and PSK-10D-12 are Active.
- VOF-6B-S12 offers an open frame construction, matching the main part’s type and mounting compatibility. Regulatory approvals and RoHS3 compliance are maintained.
- PSK-10D-12 provides higher power output, an enclosed package, and is RoHS3 compliant, with a broader range of regulatory approvals.
- For application environments requiring continued RoHS compliance and similar regulatory coverage, substitute parts meeting the same or broader standards are suitable.
Frequently Asked Questions (FAQ)
Q: What are the key criteria for substituting the VOF-6-12 AC/DC converter?
A: Substitute models must meet or exceed the input voltage range, match the output voltage (12V), support at least 500mA output current, maintain equivalent power rating (6W or greater), provide through hole mounting, and satisfy relevant compliance certifications.
Q: Are package size and mounting type critical for drop-in replacement?
A: Yes. Compatibility with the original 4-DIP module and through hole mounting is required for direct mechanical fit. Dimensional differences should be reviewed against the target PCB or chassis layout.
Q: How do approval standards affect substitute selection?
A: Approval standards must include equivalent or superseding agency certifications to satisfy safety and emissions requirements in the intended application.
Q: What is the compliance status of available substitutes?
A: Both VOF-6B-S12 and PSK-10D-12 are RoHS3 compliant. All listed regulatory and agency standards are maintained for respective applications.
Q: Is adjustment of system design required for using an enclosed versus open frame model?
A: Changes in package type (open frame vs. enclosed) may impact system-level considerations. Only package data provided should be referenced to verify mechanical integration.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts