Equivalent & Substitute Parts for VOF-15-12 (CUI Inc.)

Part Overview

The VOF-15-12 from CUI Inc. is an open frame AC/DC converter rated for 12V output at 1.25A (15W) for ITE (Commercial) applications. It features universal 85–264 VAC input, single output, 80% efficiency, through hole mounting, and multiple safety certifications. As the VOF-15-12 is classified as obsolete, identification of equivalent and substitute power supply models is required for design continuity, service replacement, and ongoing procurement where strict matching of electrical and mechanical parameters is vital.

Substiute Parts

VOF-15-12
CUI Inc.In Stock: 1060VOF-15-12 Datasheet
VOF-15-12
Current Part
VOF-15B-S12
CUI Inc.In Stock: 1507VOF-15B-S12 Datasheet
VOF-15B-S12
MFR Recommended

Key Parameters

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency Standard Number Line Regulation Load Regulation RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS
VOF-15-12 CUI Inc. VOF-15 (15W) Obsolete Open Frame 1 85 ~ 264 VAC 12V 1.25A 15 W ITE (Commercial) Universal Input 0°C ~ 60°C (With Derating) 80% Through Hole 4-DIP Module 2.76" L x 1.91" W x 0.91" H (70.0mm x 48.6mm x 23.1mm) CB Scheme, EN, IEC, SIQ, TUV, UL 55024; 60950-1; 61000-3-2; 61000-3-3 ±0.5% ±1% RoHS Compliant 1 (Unlimited) EAR99 8504.40.6001

Substitute Part Grouping Explanation

Substitute parts for the VOF-15-12 are based strictly on matching the following electrical and mechanical characteristics:

  • Output voltage (12V)
  • Output current (1.25A)
  • Output wattage (15W)
  • Universal AC input voltage range
  • Number of outputs (1)
  • Mechanical mounting (Through Hole)
  • Package / case (4-DIP Module)
  • Safety approvals and certifications
  • RoHS compliance
  • Operating temperature (with derating or improvement included)
  • Regulation parameters (line and load)
  • Application suitability (ITE Commercial)

Only substitute components that fully meet or exceed these specified parameters are included.

Parameter Comparison

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency Standard Number Line Regulation Load Regulation RoHS Status ECCN HTSUS
VOF-15-12 CUI Inc. VOF-15 (15W) Obsolete Open Frame 1 85 ~ 264 VAC 12V 1.25A 15 W ITE (Commercial) Universal Input 0°C ~ 60°C (With Derating) 80% Through Hole 4-DIP Module 2.76" L x 1.91" W x 0.91" H (70.0mm x 48.6mm x 23.1mm) CB Scheme, EN, IEC, SIQ, TUV, UL 55024; 60950-1; 61000-3-2; 61000-3-3 ±0.5% ±1% RoHS Compliant EAR99 8504.40.6001
VOF-15B-S12 CUI Inc. VOF-15B (15W) Active Open Frame 1 85 ~ 264 VAC, 120 ~ 370 VDC 12V 1.25A 15 W ITE (Commercial) Universal Input -25°C ~ 70°C (With Derating) 84.5% Through Hole 4-DIP Module 2.33" L x 1.67" W x 0.90" H (59.2mm x 42.3mm x 22.9mm) CB Scheme, EN, FCC, IEC, UL 60950-1; 61000-3-2; 61000-3-3; 62368-1 ±0.5% ±1% ROHS3 Compliant EAR99 8504.40.6001

Engineering Selection Recommendations

The VOF-15-12 is obsolete, sparking a requirement for direct substitutes. VOF-15B-S12 is classified as active and maintains equivalence in output voltage, output current, output wattage, mounting type, package, and application. Regulatory and compliance certifications are present for both models, with RoHS conformance explicitly stated. Physical dimensions and efficiency differ but remain within the required operational parameters. The VOF-15B-S12 features extended operating temperature and updated certification standards.

Frequently Asked Questions (FAQ)

Q1: What parameters must match for an equivalent substitute to be valid for the VOF-15-12?
A: Required matches include output voltage (12V), output current (1.25A), output wattage (15W), number of outputs (1), input voltage compatibility, mounting configuration, package/case type, and certifications.

Q2: Are there any differences in package or mounting between VOF-15-12 and VOF-15B-S12?
A: Both use 4-DIP module packaging with through hole mounting, ensuring footprint compatibility.

Q3: Does the substitute VOF-15B-S12 offer different efficiency or operating temperature characteristics?
A: VOF-15B-S12 offers increased efficiency (84.5% vs. 80%) and a wider operating temperature range (-25°C ~ 70°C vs. 0°C ~ 60°C).

Q4: Are certifications between the original and substitute models comparable?
A: Both models are certified for safety and electromagnetic compatibility under international standards with some updates; VOF-15B-S12 includes additional FCC and 62368-1 standards.

Q5: How does RoHS compliance influence substitute selection?
A: RoHS compliance is maintained across both models, ensuring continued adherence to environmental regulations in component selection.

Q6: Can VOF-15B-S12 be directly used in designs where VOF-15-12 was originally specified?
A: VOF-15B-S12 matches all critical electrical, mechanical, and regulatory requirements for direct substitution within the constraints provided.