Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for Vicor VI-J7J-EZ
Part Overview
The Vicor VI-J7J-EZ is an isolated DC-DC converter module designed for ITE (Commercial) applications. It delivers a single 36V output at up to 694mA, with a power rating of 25W and input voltage range of 100V to 375V. This product is categorized as obsolete, making it necessary to identify suitable alternatives with identical electrical and mechanical specifications. Substitution ensures continued system operation and compatibility in assemblies where the original module is no longer available.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-J7J-EZ | Vicor Corporation | VI-J00™ (25W) | Obsolete | Isolated Module | 1 | 100V | 375V | 36V | 694mA | 25 W | 3 kV | ITE (Commercial) | OCP, SCP | -10°C ~ 100°C | 88% | Through Hole | Half Brick | 2.28" L x 2.40" W x 0.50" H | RoHS non-compliant | REACH Unaffected |
Substitute Part Grouping Explanation
Substitute part selection is constrained strictly to matching electrical performance and mechanical compatibility. The substitute, Vicor VI-J7J-EZ-F1, is included for having identical specifications in input voltage, output voltage, output current, power rating, isolation voltage, operational temperature range, features, efficiency, mounting type, package type, and compliance. All parameters essential for direct substitution are matched. Only listed parameters were used to establish equivalency.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-J7J-EZ | Vicor Corporation | VI-J00™ (25W) | Obsolete | Isolated Module | 1 | 100V | 375V | 36V | 694mA | 25 W | 3 kV | ITE (Commercial) | OCP, SCP | -10°C ~ 100°C | 88% | Through Hole | Half Brick | 2.28" L x 2.40" W x 0.50" H | RoHS non-compliant | REACH Unaffected |
| VI-J7J-EZ-F1 | Vicor Corporation | VI-J00™ (25W) | Active | Isolated Module | 1 | 100V | 375V | 36V | 694mA | 25 W | 3 kV | ITE (Commercial) | OCP, SCP | -10°C ~ 100°C | 88% | Through Hole | Half Brick | 2.28" L x 1.86" W x 0.79" H | RoHS non-compliant | REACH Unaffected |
Engineering Selection Recommendations
The primary product, Vicor VI-J7J-EZ, is obsolete. The substitute part, Vicor VI-J7J-EZ-F1, is active and shares all listed compliance characteristics, including RoHS non-compliance and REACH unaffected status. Product selection should be based solely on the product status for replacement continuity, with attention to package dimension differences for mechanical fit.
Frequently Asked Questions (FAQ)
Q1: Are the electrical characteristics between VI-J7J-EZ and VI-J7J-EZ-F1 identical for direct substitution?
A1: All listed electrical characteristics, including input voltage range, output voltage, output current, power rating, isolation voltage, efficiency, and features, are identical.
Q2: Are there any differences in compliance between the main part and the substitute?
A2: Both VI-J7J-EZ and VI-J7J-EZ-F1 are RoHS non-compliant and REACH unaffected.
Q3: Is the mounting and package type suitable for direct mechanical replacement?
A3: Both parts use Through Hole mounting and a Half Brick package, but the substitute part has different physical dimensions. Verification of mechanical fit should be performed based on these dimensions.
Q4: Why select VI-J7J-EZ-F1 as the substitute?
A4: The substitute is active and matches all required parameters explicitly provided for equivalency, except for differences in physical dimensions.
Q5: Can the substitute operate within the same temperature range and application scope?
A5: Yes, both parts specify an operating temperature of -10°C to 100°C and are designed for ITE (Commercial) applications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts