Part Overview

The VI-J4J-EY from Vicor Corporation is an isolated DC-DC converter module offering a single 36 V output at up to 1.39 A, with a 55–100 V input range and 50 W maximum power. This product, categorized as a half brick isolated module with features such as overcurrent and short-circuit protection, is now classified as obsolete. Due to its obsolete status and continued requirements for compatible DC-DC conversion modules in existing designs, identifying substitute models with matching key electrical, mechanical, and compliance parameters is necessary.

Substiute Parts

VI-J4J-EY
Vicor CorporationIn Stock: 929VI-J4J-EY Datasheet
VI-J4J-EY
Current Part
VI-J4J-EY-F1
Vicor CorporationIn Stock: 810VI-J4J-EY-F1 Datasheet
VI-J4J-EY-F1
Similar

Key Parameters

ParameterValue
ManufacturerVicor Corporation
SeriesVI-J00™ (50W)
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)55V
Voltage - Input (Max)100V
Voltage - Output 136V
Current - Output (Max)1.39A
Power (Watts)50 W
Voltage - Isolation3 kV
ApplicationsITE (Commercial)
FeaturesOCP, SCP
Operating Temperature-10°C ~ 100°C
Efficiency88%
Mounting TypeThrough Hole
Package / CaseHalf Brick
Size / Dimension2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm)
RoHS StatusRoHS non-compliant
REACH StatusREACH Unaffected
Inventory844 Pcs New Original In Stock
Product StatusObsolete

Substitute Part Grouping Explanation

Substitution is determined by strict alignment of core electrical and mechanical parameters, including input voltage range, output voltage and current rating, power, isolation voltage, package type, efficiency, protection features, and compliance descriptors. Only those parts matching these key parameters are considered valid substitutes.

Key parameters for grouping:

  • Input Voltage Range (55–100 V)
  • Output Voltage (36 V)
  • Output Current (1.39 A)
  • Power (50 W)
  • Voltage Isolation (3 kV)
  • Efficiency (88%)
  • Operating Temperature (–10°C to 100°C)
  • Package/Case (Half Brick)
  • Mounting (Through Hole)
  • Features (OCP, SCP)
  • RoHS/REACH Status
  • Application Category (ITE, Commercial)

Parameter Comparison

Manufacturer Part Number Manufacturer Series Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status REACH Status Product Status
VI-J4J-EY Vicor Corporation VI-J00™ (50W) Isolated Module 1 55V 100V 36V 1.39A 50 W 3 kV ITE (Commercial) OCP, SCP -10°C ~ 100°C 88% Through Hole Half Brick 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) RoHS non-compliant REACH Unaffected Obsolete
VI-J4J-EY-F1 Vicor Corporation VI-J00™ (50W) Isolated Module 1 55V 100V 36V 1.39A 50 W 3 kV ITE (Commercial) OCP, SCP -10°C ~ 100°C 88% Through Hole Half Brick 2.28" L x 1.86" W x 0.79" H (57.9mm x 47.2mm x 20.1mm) RoHS non-compliant REACH Unaffected Active

Engineering Selection Recommendations

The VI-J4J-EY is classified as obsolete, and the substitute VI-J4J-EY-F1 is active. Both modules share the same series, key electrical ratings, protection features, package category, and compliance characteristics. Both parts are listed as RoHS non-compliant and REACH unaffected, with through-hole mounting and half brick format. Only the size/dimension field differs within the half brick class. Selection can be based on product lifecycle status and confirmed inventory availability.

Frequently Asked Questions (FAQ)

Q: What criteria are used to qualify VI-J4J-EY-F1 as a substitute for VI-J4J-EY?
A: Substitution is based strictly on matching electrical parameters including input voltage range, output voltage and current, power rating, isolation voltage, efficiency, protection features, package type, mounting method, compliance, and application category.

Q: Are the two DC-DC converter modules mechanically compatible?
A: Both are classified as half brick, through-hole modules from the same series. The specific size and dimensional details should be considered for direct mechanical fit where critical.

Q: Do both models have the same compliance status for RoHS and REACH?
A: Both VI-J4J-EY and VI-J4J-EY-F1 are RoHS non-compliant and REACH unaffected.

Q: Is there a difference in electrical performance between the parts?
A: The electrical parameters, including input and output ratings, efficiency, isolation voltage, and protection features are identical based on the provided data.

Q: Does the thermal specification differ between VI-J4J-EY and VI-J4J-EY-F1?
A: Both models feature the same operating temperature range of –10°C to 100°C.

Q: Why is it necessary to find a substitute part for VI-J4J-EY?
A: The main part, VI-J4J-EY, is designated obsolete, making it essential to identify a currently active DC-DC converter with strictly matching parameters for continued maintenance or production.

Request Quote (Ships tomorrow)