The Vicor Corporation VI-J0F-EX-F2 is an isolated DC-DC converter module providing a single 72V output at 1.04A, with an input range of 10V to 20V, rated for 75W output power. The product is classified as obsolete and carries a RoHS non-compliant status. Due to its end-of-life status, sourcing a form, fit, and function equivalent or substitute DC-DC converter with matching electrical and mechanical key parameters is essential for design continuity and supply chain reliability.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Vicor Corporation |
| Series | VI-J00™ (75W) |
| Product Status | Obsolete |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 10V |
| Voltage - Input (Max) | 20V |
| Voltage - Output 1 | 72V |
| Current - Output (Max) | 1.04A |
| Power (Watts) | 75 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial) |
| Features | OCP, SCP |
| Operating Temperature | -10°C ~ 100°C |
| Efficiency | 88% |
| Mounting Type | Through Hole |
| Package / Case | Half Brick |
| Size / Dimension | 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) |
| Base Product Number | VI-J0F |
| RoHS Status | RoHS non-compliant |
| MSL | Not Applicable |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
All substitute part selections are strictly based on the following parameters: series, output voltage, output current, input voltage range, output power, isolation voltage, application type, protection features, efficiency, operating temperature range, mounting type, package/case, and dimensions within the same base product number. Compliance categories such as RoHS status and regulatory certifications are also matched as provided.
Key substitution parameters:
- Input voltage range: 10V to 20V
- Output voltage: 72V
- Output current: 1.04A
- Output power: 75 W
- Isolation voltage: 3 kV
- Features: OCP, SCP
- Package: Half Brick, Through Hole
- Series: VI-J00™ (75W), Base Product Number: VI-J0F
- Compliance status (RoHS, REACH, ECCN, HTSUS)
Parameter Comparison
| Parameter | Main Part: VI-J0F-EX-F2 |
Substitute Part: VI-J0F-EX-F1 |
|---|---|---|
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VI-J00™ (75W) | VI-J00™ (75W) |
| Product Status | Obsolete | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 10V | 10V |
| Voltage - Input (Max) | 20V | 20V |
| Voltage - Output 1 | 72V | 72V |
| Current - Output (Max) | 1.04A | 1.04A |
| Power (Watts) | 75 W | 75 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | OCP, SCP | OCP, SCP |
| Operating Temperature | -10°C ~ 100°C | -10°C ~ 100°C |
| Efficiency | 88% | 88% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Half Brick | Half Brick |
| Size / Dimension | 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) | 2.28" L x 1.86" W x 0.79" H (57.9mm x 47.2mm x 20.1mm) |
| Base Product Number | VI-J0F | VI-J0F |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| MSL | Not Applicable | Not Applicable |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
The main selection criteria are the product status and compliance fields. VI-J0F-EX-F2 is obsolete, while VI-J0F-EX-F1 is active. Both parts are RoHS non-compliant and REACH unaffected. The packaging, mounting type, application category, and all critical electrical parameters are equivalent or within the same series and base product number. The only difference is the device height/dimension, which is strictly listed above; no compliance or certification differences exist based on the provided information.
Frequently Asked Questions (FAQ)
Q1: Can VI-J0F-EX-F1 be used as a direct substitute for VI-J0F-EX-F2?
A1: VI-J0F-EX-F1 matches all critical electrical parameters and features with VI-J0F-EX-F2, including input/output voltage, current, power, isolation voltage, package/case, and compliance status. The primary physical difference is the module height.
Q2: Is there any difference in the compliance certifications between these parts?
A2: Both components are RoHS non-compliant and REACH unaffected. They share the same ECCN and HTSUS codes.
Q3: Does the change in height affect the mounting method?
A3: Both VI-J0F-EX-F2 and VI-J0F-EX-F1 utilize through-hole mounting and are supplied in half brick packages. Dimensional differences are specified in the size/dimension parameter.
Q4: Does the substitute part maintain the same protection features as the original?
A4: Both parts provide OCP (over-current protection) and SCP (short-circuit protection) based strictly on the supplied parameters.
Q5: Are there differences in available stock or product status?
A5: VI-J0F-EX-F2 is obsolete, while VI-J0F-EX-F1 is active. Inventory levels are stated in the initial parameters and may influence preferred selection when immediate sourcing considerations are made.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts