The Vicor VI-B7Y-CY is an obsolete isolated DC-DC converter module, delivering a single 3.3V output at up to 10A with 33W power capability and 3 kV isolation. Due to its obsolete status and RoHS non-compliance, identification of functionally identical substitute models—especially from the same Vicor VI-200™ series—is critical for ongoing maintenance, repair, and compatible design-in scenarios where identical input/output parameters and mechanical constraints must be observed.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Features | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Operating Temperature | Applications |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-B7Y-CY | Vicor Corporation | VI-200™ (50W) | Obsolete | Isolated Module | 1 | 100V | 375V | 3.3V | 10A | 33 W | 3 kV | OCP, OTP, OVP, SCP | 90% | Through Hole | Full Brick | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) | RoHS non-compliant | -25°C ~ 85°C | ITE (Commercial) |
Substitute Part Grouping Explanation
Substitute models for the Vicor VI-B7Y-CY are determined exclusively by matching critical electrical and mechanical parameters, as provided:
- Series: VI-200™ (50W)
- Type: Isolated Module
- Number of Outputs: 1
- Voltage - Input (Min/Max): 100V to 375V
- Voltage - Output 1: 3.3V
- Current Output (Max): 10A
- Power (Watts): 33 W
- Voltage - Isolation: 3 kV
- Features: OCP, OTP, OVP, SCP
- Efficiency: 90%
- Mounting Type: Through Hole
- Package / Case: Full Brick
- Size / Dimension: All critical for system fit and replacement compatibility
- Operating Temperature: -25°C ~ 85°C
- Applications: ITE (Commercial)
- RoHS Status: Declared
Only parts with parameters identical to or fully compatible with these are considered valid substitutes.
Parameter Comparison
| Parameter | VI-B7Y-CY | VI-B7Y-CY-B1 |
|---|---|---|
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VI-200™ (50W) | VI-200™ (50W) |
| Product Status | Obsolete | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 100V | 100V |
| Voltage - Input (Max) | 375V | 375V |
| Voltage - Output 1 | 3.3V | 3.3V |
| Current - Output (Max) | 10A | 10A |
| Power (Watts) | 33 W | 33 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| Efficiency | 90% | 90% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) | 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| Operating Temperature | -25°C ~ 85°C | -25°C ~ 85°C |
| Applications | ITE (Commercial) | ITE (Commercial) |
Engineering Selection Recommendations
Selection between Vicor VI-B7Y-CY and VI-B7Y-CY-B1 is primarily determined by product status and available compliance declarations. Both models are RoHS non-compliant and REACH Unaffected, with the VI-B7Y-CY listed as Obsolete and VI-B7Y-CY-B1 as Active. All provided certifications, electrical, and mechanical attributes must be matched exactly as shown, especially size/dimension, mounting, and electrical limits for strict substitution.
Frequently Asked Questions (FAQ)
Q: What criteria are essential when selecting a substitute for Vicor VI-B7Y-CY?
A: Key criteria include matching input voltage range (100V-375V), output voltage (3.3V), output current (10A max), power rating (33 W), isolation rating (3 kV), package type (Full Brick), mounting style (Through Hole), operating temperature (-25°C ~ 85°C), RoHS/REACH declarations, and mechanical dimensions.
Q: Are there any compliance or certification concerns between VI-B7Y-CY and VI-B7Y-CY-B1?
A: Both models are RoHS non-compliant and REACH Unaffected, with the same ECCN and HTSUS codes.
Q: How does the size or height affect drop-in replacement compatibility?
A: The VI-B7Y-CY is 0.50" (12.7mm) high, while VI-B7Y-CY-B1 is 1.07" (27.1mm) high. Physical fit in the end system must be checked against height restrictions for mechanical compatibility.
Q: Are the electrical protections identical between parts?
A: Both models feature OCP (Over Current Protection), OTP (Over Temperature Protection), OVP (Over Voltage Protection), and SCP (Short Circuit Protection).
Q: Is Active status preferred for ongoing designs?
A: The active (VI-B7Y-CY-B1) status indicates continued manufacturer support and new inventory availability, in contrast to the obsolete status of VI-B7Y-CY.
Q: Do mounting styles or pinout arrangements differ?
A: Both parts use Through Hole mounting in a Full Brick package. Pinout is not specified beyond package reference.
Q: Is there a difference in efficiency or electrical performance?
A: Both parts list identical efficiency (90%) and electrical characteristics based on provided data.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts