Equivalent & Substitute Parts Reference for Vicor VI-B6L-CX DC DC Converter

Part Overview

The Vicor VI-B6L-CX is an isolated module DC DC converter designed for ITE (Commercial) applications, featuring a single output of 28V at 2.68A, with an input voltage range of 200V to 400V. It offers advanced protection features including OCP, OTP, OVP, and SCP. This model is currently classified as obsolete, necessitating the identification of suitable substitute models for continuity in designs and maintenance scenarios.

Substiute Parts

VI-B6L-CX
Vicor CorporationIn Stock: 811VI-B6L-CX Datasheet
VI-B6L-CX
Current Part
VI-B6L-CX-B1
Vicor CorporationIn Stock: 1102VI-B6L-CX-B1 Datasheet
VI-B6L-CX-B1
Similar

Key Parameters

Manufacturer Part Number Manufacturer Series Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS Product Status
VI-B6L-CX Vicor Corporation VI-200™ (75W) Isolated Module 1 200V 400V 28V 2.68A 75 W 3 kV ITE (Commercial) OCP, OTP, OVP, SCP -25°C ~ 85°C 90% Through Hole Full Brick 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 Obsolete

Substitute Part Grouping Explanation

Substitute selection is strictly governed by the following key parameters: manufacturer part number, manufacturer, series, type, number of outputs, input voltage range, output voltage and current specifications, power rating, isolation voltage, application domain, feature set, operating temperature, efficiency, mounting type, package, physical dimensions, compliance attributes, and product status. Compatibility is determined when these parameters are matched between the main part and substitute parts in the same product category.

Parameter Comparison

Parameter Main Part (VI-B6L-CX) Substitute Part (VI-B6L-CX-B1)
Manufacturer Part Number VI-B6L-CX VI-B6L-CX-B1
Manufacturer Vicor Corporation Vicor Corporation
Series VI-200™ (75W) VI-200™ (75W)
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 200V 200V
Voltage - Input (Max) 400V 400V
Voltage - Output 1 28V 28V
Current - Output (Max) 2.68A 2.68A
Power (Watts) 75 W 75 W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial) ITE (Commercial)
Features OCP, OTP, OVP, SCP OCP, OTP, OVP, SCP
Operating Temperature -25°C ~ 85°C -25°C ~ 85°C
Efficiency 90% 90%
Mounting Type Through Hole Through Hole
Package / Case Full Brick Full Brick
Size / Dimension 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm)
RoHS Status RoHS non-compliant RoHS non-compliant
Moisture Sensitivity Level (MSL) Not Applicable Not Applicable
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580
Product Status Obsolete Active

Engineering Selection Recommendations

The Vicor VI-B6L-CX is obsolete. The substitute VI-B6L-CX-B1 matches all key electrical and mechanical parameters provided, including input and output specifications, feature set, mounting type, package, and compliance attributes. Both models are RoHS non-compliant and REACH unaffected, and share the same ECCN and HTSUS classifications. The substitute part's active status makes it suitable for ongoing production and maintenance under identical compliance and application requirements.

Frequently Asked Questions (FAQ)

Q1: What criteria are used to determine if VI-B6L-CX-B1 can substitute VI-B6L-CX?
Matching parameters include input and output voltage, current, power rating, isolation voltage, feature set, mechanical package, mounting, application type, operating temperature range, compliance, and manufacturer.

Q2: Are there any mechanical differences between the VI-B6L-CX and VI-B6L-CX-B1 that affect substitution?
Both use a Full Brick package with identical length and width; the height differs (0.50" vs. 1.07"), which must be verified for mechanical fit in the intended enclosure.

Q3: Is there any difference in compliance and environmental certifications between the two models?
Both are classified as RoHS non-compliant and entirely REACH unaffected. There are no differences in ECCN or HTSUS codes.

Q4: Can the substitute part be used in the same application category?
Both models are intended for ITE (Commercial) applications and share identical electrical specifications and protective features.

Q5: Does product status affect selection?
As the main part (VI-B6L-CX) is obsolete, selection should be directed towards the substitute (VI-B6L-CX-B1), which holds an active status. This ensures availability for new designs and service requirements.

Request Quote (Ships tomorrow)