Equivalent & Substitute Parts for Vicor VI-B6J-EX

Part Overview

The Vicor VI-B6J-EX is an isolated module DC-DC converter in the VI-200™ (75W) series. This unit provides a single output: 36V at up to 2.08A, with an input range of 200V to 400V. The converter offers 3 kV isolation, is suited to ITE (Commercial) applications, supports features such as OCP, OTP, OVP, SCP, and is designed for through hole mounting in a full brick case. The product is classified as obsolete, necessitating the identification of alternative part numbers for ongoing design and replacement requirements.

Substiute Parts

VI-B6J-EX
Vicor CorporationIn Stock: 973VI-B6J-EX Datasheet
VI-B6J-EX
Current Part
VI-B6J-EX-B1
Vicor CorporationIn Stock: 1173VI-B6J-EX-B1 Datasheet
VI-B6J-EX-B1
Similar

Key Parameters

Parameter Main Part (VI-B6J-EX)
Manufacturer Vicor Corporation
Series VI-200™ (75W)
Type Isolated Module
Number of Outputs 1
Voltage - Input (Min) 200V
Voltage - Input (Max) 400V
Voltage - Output 1 36V
Current - Output (Max) 2.08A
Power (Watts) 75W
Voltage - Isolation 3 kV
Applications ITE (Commercial)
Features OCP, OTP, OVP, SCP
Operating Temperature -10°C ~ 85°C
Efficiency 88%
Mounting Type Through Hole
Package / Case Full Brick
Size / Dimension 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm)
RoHS Status RoHS non-compliant
MSL Not Applicable
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8504.40.9580

Substitute Part Grouping Explanation

Substitute parts for the Vicor VI-B6J-EX are determined by strict adherence to electrical and mechanical parameters as specified. Key substitution parameters for DC-DC converters in the VI-200™ (75W) series include: identical output voltage (36V), maximum output current (2.08A), input voltage range (200V to 400V), isolation voltage (3 kV), efficiency (88%), mounting type (through hole), package/case (full brick), features (OCP, OTP, OVP, SCP), operating temperature (-10°C to 85°C), and compliance characteristics (RoHS, REACH, ECCN, HTSUS).

Parameter Comparison

Parameter Main Part (VI-B6J-EX) Substitute Part (VI-B6J-EX-B1)
Manufacturer Vicor Corporation Vicor Corporation
Series VI-200™ (75W) VI-200™ (75W)
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 200V 200V
Voltage - Input (Max) 400V 400V
Voltage - Output 1 36V 36V
Current - Output (Max) 2.08A 2.08A
Power (Watts) 75W 75W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial) ITE (Commercial)
Features OCP, OTP, OVP, SCP OCP, OTP, OVP, SCP
Operating Temperature -10°C ~ 85°C -10°C ~ 85°C
Efficiency 88% 88%
Mounting Type Through Hole Through Hole
Package / Case Full Brick Full Brick
RoHS Status RoHS non-compliant RoHS non-compliant
MSL Not Applicable Not Applicable
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580
Size / Dimension 4.60" L x 2.40" W x 0.50" H 4.60" L x 2.40" W x 1.07" H

Engineering Selection Recommendations

For direct substitution of the obsolete Vicor VI-B6J-EX, select the Vicor VI-B6J-EX-B1 based on identical key electrical and mechanical parameters and product certifications. Both models are RoHS non-compliant, share the same REACH status, ECCN, HTSUS, mounting type, and package category. Selection is based on matching product status and compliance characteristics as provided.

Frequently Asked Questions (FAQ)

Q1: What are the essential criteria for substituting DC-DC converters in the VI-200™ (75W) series?
A1: Substitution requires matching output voltage, output current, input voltage range, isolation voltage, efficiency, package type, mounting style, feature set, operating temperature, and regulatory status.

Q2: Are the dimensions of the substitute part VI-B6J-EX-B1 compatible with VI-B6J-EX in all mechanical environments?
A2: Both parts maintain full brick form factor. The substitute (VI-B6J-EX-B1) has a height of 1.07", compared to the main part's 0.50". Ensure vertical clearance accommodates this difference.

Q3: How do compliance statuses (RoHS, REACH) impact selection?
A3: Both models are RoHS non-compliant and REACH unaffected. Substitute parts must align with the original part's compliance requirements per application policies.

Q4: Are there differences in electrical features between VI-B6J-EX and VI-B6J-EX-B1?
A4: No differences; both parts offer OCP, OTP, OVP, SCP, identical voltage and current ratings, input ranges, efficiency, and isolation.

Q5: Does product status affect ongoing design choice?
A5: VI-B6J-EX is obsolete, while VI-B6J-EX-B1 is active, making it suitable for ongoing designs where identical operational characteristics are required.

Request Quote (Ships tomorrow)