Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for Vicor VI-B6J-EX
Part Overview
The Vicor VI-B6J-EX is an isolated module DC-DC converter in the VI-200™ (75W) series. This unit provides a single output: 36V at up to 2.08A, with an input range of 200V to 400V. The converter offers 3 kV isolation, is suited to ITE (Commercial) applications, supports features such as OCP, OTP, OVP, SCP, and is designed for through hole mounting in a full brick case. The product is classified as obsolete, necessitating the identification of alternative part numbers for ongoing design and replacement requirements.
Substiute Parts
Key Parameters
| Parameter | Main Part (VI-B6J-EX) |
|---|---|
| Manufacturer | Vicor Corporation |
| Series | VI-200™ (75W) |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 200V |
| Voltage - Input (Max) | 400V |
| Voltage - Output 1 | 36V |
| Current - Output (Max) | 2.08A |
| Power (Watts) | 75W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP |
| Operating Temperature | -10°C ~ 85°C |
| Efficiency | 88% |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) |
| RoHS Status | RoHS non-compliant |
| MSL | Not Applicable |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute parts for the Vicor VI-B6J-EX are determined by strict adherence to electrical and mechanical parameters as specified. Key substitution parameters for DC-DC converters in the VI-200™ (75W) series include: identical output voltage (36V), maximum output current (2.08A), input voltage range (200V to 400V), isolation voltage (3 kV), efficiency (88%), mounting type (through hole), package/case (full brick), features (OCP, OTP, OVP, SCP), operating temperature (-10°C to 85°C), and compliance characteristics (RoHS, REACH, ECCN, HTSUS).
Parameter Comparison
| Parameter | Main Part (VI-B6J-EX) | Substitute Part (VI-B6J-EX-B1) |
|---|---|---|
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VI-200™ (75W) | VI-200™ (75W) |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 200V | 200V |
| Voltage - Input (Max) | 400V | 400V |
| Voltage - Output 1 | 36V | 36V |
| Current - Output (Max) | 2.08A | 2.08A |
| Power (Watts) | 75W | 75W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| Operating Temperature | -10°C ~ 85°C | -10°C ~ 85°C |
| Efficiency | 88% | 88% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| MSL | Not Applicable | Not Applicable |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H | 4.60" L x 2.40" W x 1.07" H |
Engineering Selection Recommendations
For direct substitution of the obsolete Vicor VI-B6J-EX, select the Vicor VI-B6J-EX-B1 based on identical key electrical and mechanical parameters and product certifications. Both models are RoHS non-compliant, share the same REACH status, ECCN, HTSUS, mounting type, and package category. Selection is based on matching product status and compliance characteristics as provided.
Frequently Asked Questions (FAQ)
Q1: What are the essential criteria for substituting DC-DC converters in the VI-200™ (75W) series?
A1: Substitution requires matching output voltage, output current, input voltage range, isolation voltage, efficiency, package type, mounting style, feature set, operating temperature, and regulatory status.
Q2: Are the dimensions of the substitute part VI-B6J-EX-B1 compatible with VI-B6J-EX in all mechanical environments?
A2: Both parts maintain full brick form factor. The substitute (VI-B6J-EX-B1) has a height of 1.07", compared to the main part's 0.50". Ensure vertical clearance accommodates this difference.
Q3: How do compliance statuses (RoHS, REACH) impact selection?
A3: Both models are RoHS non-compliant and REACH unaffected. Substitute parts must align with the original part's compliance requirements per application policies.
Q4: Are there differences in electrical features between VI-B6J-EX and VI-B6J-EX-B1?
A4: No differences; both parts offer OCP, OTP, OVP, SCP, identical voltage and current ratings, input ranges, efficiency, and isolation.
Q5: Does product status affect ongoing design choice?
A5: VI-B6J-EX is obsolete, while VI-B6J-EX-B1 is active, making it suitable for ongoing designs where identical operational characteristics are required.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts