Part Overview
The Vicor Corporation VI-B6B-EW is an isolated DC-DC converter module delivering 95V at up to 1.05A from a 200V to 400V input, rated at 100W. It is designed for ITE (commercial) applications and incorporates OCP, OTP, OVP, and SCP features. The module utilizes a through-hole mounting full brick package and provides isolation up to 3 kV. The product is classified as obsolete, making alternative model selection necessary for ongoing projects, spares, and designs requiring the same electrical and mechanical profile.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-B6B-EW | Vicor Corporation | VI-200™ (100W) | Obsolete | Isolated Module | 1 | 200V | 400V | 95V | 1.05A | 100 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -10°C ~ 85°C | 88% | Through Hole | Full Brick | 4.60" L x 2.40" W x 0.50" H | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution is based strictly on matching electrical and mechanical parameters as per the product category: output voltage, output current, input voltage range, isolation voltage, features, operating temperature range, efficiency, mounting type, and package/case dimensions. Compliance and product status are also factored. All substitute parts listed adhere precisely to these parameters. No speculative substitutions are included.
Parameter Comparison
| Manufacturer Part Number | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-B6B-EW | VI-200™ (100W) | Obsolete | Isolated Module | 1 | 200V | 400V | 95V | 1.05A | 100 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -10°C ~ 85°C | 88% | Through Hole | Full Brick | 4.60" L x 2.40" W x 0.50" H | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
| VI-B6B-EW-B1 | VI-200™ (100W) | Active | Isolated Module | 1 | 200V | 400V | 95V | 1.05A | 100 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -10°C ~ 85°C | 88% | Through Hole | Full Brick | 4.60" L x 2.40" W x 1.07" H | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
Selection should prioritize product status, inventory availability, and compliance information. VI-B6B-EW is obsolete. VI-B6B-EW-B1 is active and available. Both models are RoHS non-compliant and REACH unaffected, with identical electrical characteristics. A slight difference exists in module height: VI-B6B-EW (0.50" H) and VI-B6B-EW-B1 (1.07" H), which must be accounted for in mechanical layout.
Frequently Asked Questions (FAQ)
Q1: What are the main criteria for substituting VI-B6B-EW with VI-B6B-EW-B1?
A1: Substitution is based on matching output voltage, output current, input range, isolation voltage, features, operating temperature, efficiency, package size, and compliance attributes.
Q2: Is there any difference in the electrical performance between the two parts?
A2: There is no difference in electrical performance based on provided specifications. Both provide the same output and feature set.
Q3: Are the package dimensions interchangeable?
A3: Both are full brick format with identical length and width. The height differs: VI-B6B-EW is 0.50" while VI-B6B-EW-B1 is 1.07". Layout must accommodate the height difference.
Q4: What compliance considerations are there?
A4: Both parts are RoHS non-compliant, REACH unaffected, and have the same ECCN and HTSUS codes. Compliance status should be checked for application requirements.
Q5: Are there any differences in series or mounting type?
A5: Both belong to the VI-200™ (100W) series and use through-hole mounting. There is no difference in mounting type.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts