Equivalent & Substitute Parts Reference for Vicor VI-B5J-CV

Part Overview

The Vicor VI-B5J-CV is an isolated DC DC converter module designed for commercial ITE applications, featuring a single 36V output at up to 4.17A with an input voltage range from 100V to 200V. The product delivers up to 150W of power and incorporates protection features such as OCP, OTP, OVP, and SCP. The module is delivered in a full brick through-hole package. This part is currently listed as obsolete, necessitating identification of alternative models to ensure continuity in designs requiring these electrical and mechanical specifications.

Substiute Parts

VI-B5J-CV
Vicor CorporationIn Stock: 1203VI-B5J-CV Datasheet
VI-B5J-CV
Current Part
VI-B5J-CV-B1
Vicor CorporationIn Stock: 1056VI-B5J-CV-B1 Datasheet
VI-B5J-CV-B1
Similar

Key Parameters

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS
VI-B5J-CV Vicor Corporation VI-200™ (150W) Obsolete Isolated Module 1 100V 200V 36V 4.17A 150 W 3 kV ITE (Commercial) OCP, OTP, OVP, SCP -25°C ~ 85°C 90% Through Hole Full Brick 4.60" L x 2.40" W x 0.50" H RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580

Substitute Part Grouping Explanation

The substitute part selection for the Vicor VI-B5J-CV is based strictly on matching the following key parameters: input voltage range, output voltage, output current, power rating, isolation voltage, mounting type, package/case format, features, operating temperature range, product category, and compliance fields. Substitution is permitted only when these parameters are identical to those of the main part, ensuring full electrical and mechanical compatibility within the category of DC DC isolated module converters.

Parameter Comparison

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS
VI-B5J-CV Vicor Corporation VI-200™ (150W) Obsolete Isolated Module 1 100V 200V 36V 4.17A 150 W 3 kV ITE (Commercial) OCP, OTP, OVP, SCP -25°C ~ 85°C 90% Through Hole Full Brick 4.60" L x 2.40" W x 0.50" H RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580
VI-B5J-CV-B1 Vicor Corporation VI-200™ (150W) Active Isolated Module 1 100V 200V 36V 4.17A 150 W 3 kV ITE (Commercial) OCP, OTP, OVP, SCP -25°C ~ 85°C 90% Through Hole Full Brick 4.60" L x 2.40" W x 1.07" H RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580

Engineering Selection Recommendations

Selection of VI-B5J-CV-B1 as a substitute for VI-B5J-CV is supported by identical input/output electrical specifications, environmental and mechanical ratings, protection features, and compliance declarations. Both parts are RoHS non-compliant and REACH unaffected, with identical ECCN and HTSUS classifications. The main difference is product status: VI-B5J-CV is obsolete, while VI-B5J-CV-B1 is active. For applications subject to ongoing regulatory compliance or longevity requirements, only parameters provided should be considered.

Frequently Asked Questions (FAQ)

Q: What parameters define equivalency for DC DC converter module substitution?
A: Equivalency is defined by input voltage range, output voltage and current, power rating, isolation voltage, mounting type, package/case format, operating temperature, efficiency, features, and compliance fields.

Q: Are the mechanical dimensions identical between the VI-B5J-CV and VI-B5J-CV-B1?
A: Both use the full brick format, with matching length and width; height differs (VI-B5J-CV: 0.50" H, VI-B5J-CV-B1: 1.07" H). Verify system clearance for height.

Q: Do both parts share the same certifications and compliance status?
A: Both models are RoHS non-compliant, REACH unaffected, have MSL not applicable, and share the same ECCN and HTSUS codes.

Q: Is the electrical performance between VI-B5J-CV and VI-B5J-CV-B1 identical?
A: All electrical specifications provided are identical, including input voltage range, output voltage, output current, power rating, isolation voltage, and efficiency.

Q: Why is substitution necessary for the VI-B5J-CV?
A: Substitution is necessary due to the obsolete status of the VI-B5J-CV, ensuring availability for designs requiring these module parameters.

Q: What application categories are supported?
A: Both components support ITE (Commercial) applications as specified.

Q: Are there differences in mounting or package type?
A: Both parts use through-hole mounting and are supplied in full brick packaging. Height is the only dimensional difference within the provided parameters.