Request Quote
(Ships tomorrow)
Vicor VI-B5B-CU Equivalent & Substitute Parts Reference
Part Overview
The Vicor Corporation VI-B5B-CU is an obsolete isolated DC-DC converter module capable of delivering 95V at 2.11A output from a 100V–200V input range, with a rated power of 200W. It targets ITE (commercial) applications and features advanced protections including OCP, OTP, OVP, and SCP. Since the product status is "Obsolete," sourcing alternative models is required to maintain existing systems and designs.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Series | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Product Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-B5B-CU | VI-200™ (200W) | Isolated Module | 1 | 100V | 200V | 95V | 2.11A | 200W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" x 2.40" x 0.50" (116.8mm x 61.0mm x 12.7mm) | RoHS non-compliant | Obsolete |
Substitute Part Grouping Explanation
Eligible substitute selection for DC-DC converter products is determined strictly by matching electrical and mechanical parameters. Substitutability is confirmed based on:
- Input voltage range
- Output voltage and output current
- Maximum power rating
- Electrical isolation rating
- Operating temperature range
- Mechanical mounting type and package/case dimensions
- Application suitability
- Features (OCP, OTP, OVP, SCP)
- Compliance (RoHS, REACH) No additional parameters outside those provided have been included.
Parameter Comparison
| Manufacturer Part Number | Series | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Product Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-B5B-CU | VI-200™ (200W) | Isolated Module | 1 | 100V | 200V | 95V | 2.11A | 200W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" x 2.40" x 0.50" (116.8mm x 61.0mm x 12.7mm) | RoHS non-compliant | Obsolete |
| VI-B5B-CU-B1 | VI-200™ (200W) | Isolated Module | 1 | 100V | 200V | 95V | 2.11A | 200W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" x 2.40" x 1.07" (116.8mm x 61.0mm x 27.1mm) | RoHS non-compliant | Active |
Engineering Selection Recommendations
When selecting an equivalent or substitute for the Vicor VI-B5B-CU, reference only the provided product status, compliance, and available certifications. Both the VI-B5B-CU and VI-B5B-CU-B1 are classified as RoHS non-compliant and REACH unaffected. The substitute part VI-B5B-CU-B1 is currently active and available, representing a valid alternative for designs requiring identical electrical and mechanical attributes.
Frequently Asked Questions (FAQ)
Q: What are the main criteria for substituting the Vicor VI-B5B-CU?
A: Substitute selection is strictly based on input voltage range, output voltage and current, isolation rating, power rating, operating temperature range, mounting type, package/case, application, features, and compliance status as provided.
Q: Are the VI-B5B-CU and VI-B5B-CU-B1 mechanically interchangeable?
A: Both use the full brick package and identical length and width; the VI-B5B-CU-B1 has greater height (1.07" vs. 0.50").
Q: Do both parts share the same electrical specifications and protection features?
A: All listed electrical and protection features are identical, including input/output ratings, isolation, efficiency, and protections (OCP, OTP, OVP, SCP).
Q: Does the substitute part uphold the same compliance standards?
A: Both parts are RoHS non-compliant and REACH unaffected as stated.
Q: Is active status important in substitute evaluation?
A: The VI-B5B-CU-B1 is active. Product status directly impacts availability for ongoing designs and inventory considerations.
Q: What application category do both models support?
A: Both are specified for ITE (commercial) environments.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts