The Vicor VI-2NT-EW is an isolated module DC DC converter providing a single 6.5V output at up to 15.38A from a 36V–76V input. It belongs to the VI-200™ Series (100W), supports ITE (Commercial) applications, and features comprehensive protection circuits. The product is classified as obsolete, making identification of equivalent and substitute models necessary to ensure design continuity and inventory availability for both maintenance and new designs.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | VI-2NT-EW |
| Manufacturer | Vicor Corporation |
| Series | VI-200™ (100W) |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Input Voltage Range | 36V – 76V |
| Output Voltage | 6.5V |
| Output Current (Max) | 15.38A |
| Power (Watts) | 100 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP |
| Operating Temperature | -10°C ~ 85°C |
| Efficiency | 88% |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H |
| RoHS Status | RoHS non-compliant |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution is determined by matching critical electrical and mechanical parameters, ensuring the functional equivalence of the DC DC converter within the system. Allowed substitution is strictly based on:
- Series and product type: VI-200™ (100W); Isolated Module
- Number of outputs: 1
- Input voltage range: 36V–76V
- Output voltage: 6.5V
- Maximum output current: 15.38A
- Continuous power: 100 W
- Isolation voltage: 3 kV
- Feature set: OCP, OTP, OVP, SCP
- Operating temperature range: -10°C ~ 85°C
- Efficiency: 88%
- Mounting and package: Through Hole, Full Brick Parts are eligible for substitution only if all listed parameters match exactly.
Parameter Comparison
| Parameter | Main Part (VI-2NT-EW) | Substitute Part (VI-2NT-EW-B1) |
|---|---|---|
| Manufacturer Part Number | VI-2NT-EW | VI-2NT-EW-B1 |
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VI-200™ (100W) | VI-200™ (100W) |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 36V | 36V |
| Voltage - Input (Max) | 76V | 76V |
| Voltage - Output 1 | 6.5V | 6.5V |
| Current - Output (Max) | 15.38A | 15.38A |
| Power (Watts) | 100 W | 100 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| Operating Temperature | -10°C ~ 85°C | -10°C ~ 85°C |
| Efficiency | 88% | 88% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H | 4.60" L x 2.40" W x 1.07" H |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
The main part, VI-2NT-EW, is obsolete. The substitute part, VI-2NT-EW-B1, is active and offers identical electrical parameters, mounting type, feature set, and certifications. Both parts are RoHS non-compliant and have unaffected REACH status. Mechanical differences are limited to the height of the package, which does not alter mounting type or footprint as per provided data. Given matching compliance and certifications, the substitute part can be selected where the mechanical envelope accommodates the different height dimension.
Frequently Asked Questions (FAQ)
Q1: What parameters must match for a VI-2NT-EW substitute?
A1: Substitution is valid when part number, series, type, number of outputs, input/output voltages, output current, power rating, isolation voltage, operating temperature, efficiency, mounting type, package/case, compliance status, and listed features are equivalent.
Q2: Does the substitute VI-2NT-EW-B1 maintain the same electrical performance?
A2: VI-2NT-EW-B1 matches all specified electrical parameters, including output, input range, features, and efficiency, ensuring functional equivalence within the design.
Q3: Are there differences in mechanical size or packaging between VI-2NT-EW and substitutes?
A3: VI-2NT-EW-B1 has a greater height (1.07" vs 0.50"), but shares the same length, width, and mounting type (Full Brick, Through Hole).
Q4: How do compliance and certification affect substitution?
A4: Both VI-2NT-EW and VI-2NT-EW-B1 are RoHS non-compliant, REACH unaffected, and classified as ECCN EAR99 and HTSUS 8504.40.9580, permitting substitution within environments where compliance criteria are consistent.
Q5: Can I use VI-2NT-EW-B1 in the same PCB footprint as VI-2NT-EW?
A5: Both parts are Full Brick, Through Hole modules with the same length and width; confirm vertical clearance in the application to accommodate the substitute's height.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts