Equivalent & Substitute Parts for Vicor VI-2NJ-CY DC DC Converter
Part Overview
The Vicor VI-2NJ-CY is an isolated DC DC converter module with a single 36V output, supporting an input range of 36V to 76V, output current of 1.39A, and a power rating of 50W. This module is designed for ITE (Commercial) applications and features OCP, OTP, OVP, and SCP protections. The product status is listed as obsolete, necessitating identification of alternative or substitute models in order to maintain design continuity for assemblies currently utilizing the VI-2NJ-CY.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Description | Series | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-2NJ-CY | Vicor Corporation | DC DC CONVERTER 36V 50W | VI-200™ (50W) | Isolated Module | 1 | 36V | 76V | 36V | 1.39A | 50 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" L x 2.40" W x 0.50" H | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Suitable substitute parts must match the Vicor VI-2NJ-CY in all key functional areas: electrical rating, series, protection features, isolation, mounting style, package type, operating temperature range, and compliance/certification status. The following substitution is based strictly on the parameters provided: part number, input/output ratings, power, mounting, size, and relevant certifications.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Description | Series | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | MSL | REACH Status | ECCN | HTSUS | Product Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-2NJ-CY | Vicor Corporation | DC DC CONVERTER 36V 50W | VI-200™ (50W) | Isolated Module | 1 | 36V | 76V | 36V | 1.39A | 50 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" L x 2.40" W x 0.50" H | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | Obsolete |
| VI-2NJ-CY-B1 | Vicor Corporation | DC DC CONVERTER 36V 50W | VI-200™ (50W) | Isolated Module | 1 | 36V | 76V | 36V | 1.39A | 50 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" L x 2.40" W x 1.07" H | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | Active |
Engineering Selection Recommendations
Selection between the Vicor VI-2NJ-CY and VI-2NJ-CY-B1 should prioritize product status. VI-2NJ-CY is obsolete, while VI-2NJ-CY-B1 remains active. Both modules are RoHS non-compliant and unaffected by REACH, with identical electrical and mechanical parameters except for height. Their ECCN and HTSUS codes match, ensuring consistent regulatory classification.
Frequently Asked Questions (FAQ)
Q1: What are the primary criteria for substituting the Vicor VI-2NJ-CY DC DC converter module?
A1: Substitution requires identical input range, output voltage and current, power rating, series, protection features, isolation voltage, mounting type, package/case, application category, and compliance/certification status.
Q2: Are there any differences in electrical or operating performance between VI-2NJ-CY and VI-2NJ-CY-B1?
A2: No differences are present in input voltage, output voltage, current, power, efficiency, isolation voltage, protection features, mounting type, or operating temperature range based on provided parameters.
Q3: What is the impact of the package size variation between these models?
A3: Both models share length and width (4.60" x 2.40"). The height differs: VI-2NJ-CY (0.50") and VI-2NJ-CY-B1 (1.07"), requiring mechanical accommodation for VI-2NJ-CY-B1 if replacing in existing assemblies.
Q4: How should compliance status affect substitute selection?
A4: Both modules are RoHS non-compliant and REACH unaffected, with identical ECCN and HTSUS codes. Substitute selection remains unaffected based on compliance parameters provided.
Q5: Do mounting and mechanical form factors influence system compatibility?
A5: Both models use through-hole mounting and the full brick package type. Compatibility is determined by adherence to published mechanical dimensions. The height discrepancy must be considered for enclosure or PCB layout constraints.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts