Vicor VI-2NH-CV Equivalent & Substitute Parts Reference

Part Overview

The Vicor VI-2NH-CV is an isolated DC-DC converter module designed for ITE (Commercial) applications. It features 1 output (52V, 2.88A, 150W) with a 36V–76V input range and 3 kV isolation. The product status is Obsolete. Identifying suitable alternative models is necessary for ongoing maintenance, system build continuity, and production that depends on this particular power supply module.

Substiute Parts

VI-2NH-CV
Vicor CorporationIn Stock: 1992VI-2NH-CV Datasheet
VI-2NH-CV
Current Part
VI-2NH-CV-B1
Vicor CorporationIn Stock: 856VI-2NH-CV-B1 Datasheet
VI-2NH-CV-B1
Similar

Key Parameters

ParameterValue
Manufacturer Part NumberVI-2NH-CV
SeriesVI-200™ (150W)
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)36V
Voltage - Input (Max)76V
Voltage - Output 152V
Current - Output (Max)2.88A
Power (Watts)150 W
Voltage - Isolation3 kV
Efficiency90%
Operating Temperature-25°C ~ 85°C
Mounting TypeThrough Hole
Package / CaseFull Brick
Size / Dimension4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm)
RoHS StatusRoHS non-compliant
MSLNot Applicable
REACH StatusREACH Unaffected

Substitute Part Grouping Explanation

Substitute parts are identified by matching all electrical and mechanical parameters as provided. Substitution eligibility requires equivalence in: manufacturer series, input voltage range, output voltage and current, power rating, isolation voltage, efficiency, number of outputs, package type, and RoHS/REACH compliance status. Only parts meeting all listed criteria are included as substitutes.

Parameter Comparison

Parameter VI-2NH-CV (Main) VI-2NH-CV-B1 (Substitute)
SeriesVI-200™ (150W)VI-200™ (150W)
TypeIsolated ModuleIsolated Module
Number of Outputs11
Voltage - Input (Min)36V36V
Voltage - Input (Max)76V76V
Voltage - Output 152V52V
Current - Output (Max)2.88A2.88A
Power (Watts)150 W150 W
Voltage - Isolation3 kV3 kV
Efficiency90%90%
Operating Temperature-25°C ~ 85°C-25°C ~ 85°C
Mounting TypeThrough HoleThrough Hole
Package / CaseFull BrickFull Brick
Size / Dimension4.60" L x 2.40" W x 0.50" H4.60" L x 2.40" W x 1.07" H
RoHS StatusRoHS non-compliantRoHS non-compliant
MSLNot ApplicableNot Applicable
REACH StatusREACH UnaffectedREACH Unaffected
Product StatusObsoleteActive

Engineering Selection Recommendations

Selection between the Vicor VI-2NH-CV and VI-2NH-CV-B1 should be based on product availability and compliance requirements. Both parts are RoHS non-compliant and REACH unaffected. VI-2NH-CV is obsolete, while VI-2NH-CV-B1 is active. Dimensional differences in height should be evaluated for fit in mechanical assemblies.

Frequently Asked Questions (FAQ)

Q1: What determines if VI-2NH-CV-B1 is a valid substitute for VI-2NH-CV?
A1: The substitute meets all critical electrical and mechanical parameters including voltage/current ratings, isolation, and package format, with only a difference in module height.

Q2: Are there compliance or certification differences between the main and substitute parts?
A2: Both parts are RoHS non-compliant and REACH unaffected.

Q3: Will the change in module height affect compatibility?
A3: Mechanical compatibility should be verified, as VI-2NH-CV-B1 has a greater height (1.07" vs 0.50"). All other dimensions match.

Q4: Is there a change in electrical performance between the main and substitute parts?
A4: Electrical performance parameters including input/output ratings and efficiency are identical.

Q5: Why is substitution necessary for VI-2NH-CV?
A5: The main part is obsolete, necessitating identification of active alternatives to ensure continuous system function.

Request Quote (Ships tomorrow)