The Vicor VI-24K-CV is an isolated DC DC converter module featuring a single 40V output at 3.75A, designed for ITE (commercial) applications. It operates from a 55V to 100V input, delivers 150W of power, and offers protection features such as OCP, OTP, OVP, and SCP. This model has been designated as “Obsolete,” making it necessary to identify alternative models to ensure availability, support continuity, and compatible integration within existing designs.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | VI-24K-CV |
| Series | VI-200™ (150W) |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 55V |
| Voltage - Input (Max) | 100V |
| Voltage - Output 1 | 40V |
| Current - Output (Max) | 3.75A |
| Power (Watts) | 150 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP |
| Operating Temperature | -25°C ~ 85°C |
| Efficiency | 90% |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H |
| RoHS Status | RoHS non-compliant |
| REACH Status | REACH Unaffected |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitute components are selected strictly based on identical specifications in electrical and mechanical parameters. The matched parameters include manufacturer part number, series, type, number of outputs, input voltage range, output voltage, output current, maximum power, isolation voltage, application, protection features, operating temperature, efficiency, mounting type, package, dimensions, RoHS and REACH compliance, and product status. Only parts with all required parameters matching or within allowed values are considered suitable substitutes.
Parameter Comparison
| Parameter | VI-24K-CV | VI-24K-CV-B1 |
|---|---|---|
| Series | VI-200™ (150W) | VI-200™ (150W) |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 55V | 55V |
| Voltage - Input (Max) | 100V | 100V |
| Voltage - Output 1 | 40V | 40V |
| Current - Output (Max) | 3.75A | 3.75A |
| Power (Watts) | 150 W | 150 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| Operating Temperature | -25°C ~ 85°C | -25°C ~ 85°C |
| Efficiency | 90% | 90% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H | 4.60" L x 2.40" W x 1.07" H |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
Selection between Vicor VI-24K-CV and VI-24K-CV-B1 can be based on product status and compliance. Both modules are RoHS non-compliant and REACH unaffected. VI-24K-CV is obsolete, while VI-24K-CV-B1 maintains active status, supporting ongoing supply availability. No differences in electrical performance parameters are stated. Dimensional changes in height (1.07" for VI-24K-CV-B1 vs. 0.50" for VI-24K-CV) may impact mechanical integration if vertical clearance is restricted.
Frequently Asked Questions (FAQ)
Q1: What parameters must match when selecting a substitute for the VI-24K-CV DC DC converter?
Key parameters for substitution include input voltage range (55V to 100V), output voltage (40V), output current (3.75A), power rating (150W), voltage isolation (3kV), package type (Full Brick), and protection features (OCP, OTP, OVP, SCP).
Q2: Are both VI-24K-CV and VI-24K-CV-B1 RoHS compliant?
Both models are RoHS non-compliant.
Q3: What are the physical differences between VI-24K-CV and VI-24K-CV-B1?
Both units share the same length and width. The VI-24K-CV is 0.50" high, while VI-24K-CV-B1 is 1.07" high. This affects the mechanical fit and may require verification in height-constrained assemblies.
Q4: Does the substitute part VI-24K-CV-B1 have the same electrical performance as the original VI-24K-CV?
The provided data shows equivalent electrical performance across all specified parameters.
Q5: Can VI-24K-CV-B1 be considered a direct substitute in all mechanical designs?
Mechanical suitability depends on the height difference (VI-24K-CV: 0.50" H, VI-24K-CV-B1: 1.07" H). Ensure height accommodation in the target application.
Q6: What is the significance of product status in selecting substitutes?
VI-24K-CV is obsolete. VI-24K-CV-B1 is active, supporting supply continuity for maintenance and production requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts