Equivalent & Substitute Parts Reference: VI-22Y-CX

Part Overview

Manufacturer Part Number VI-22Y-CX from Vicor Corporation is an isolated DC-DC converter module designed for ITE (Commercial) applications, providing 3.3V output at up to 15A with an input range of 21V to 56V, rated at 50W power. Product status is obsolete, making identification of alternative model numbers essential for maintaining design continuity and supporting replacement in legacy systems. Substitution is required strictly due to product status, ensuring ongoing availability.

Substiute Parts

VI-22Y-CX
Vicor CorporationIn Stock: 919VI-22Y-CX Datasheet
VI-22Y-CX
Current Part
VI-22Y-CX-B1
Vicor CorporationIn Stock: 744VI-22Y-CX-B1 Datasheet
VI-22Y-CX-B1
Similar

Key Parameters

Manufacturer Part Number Series Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status MSL REACH Status ECCN HTSUS
VI-22Y-CX VI-200™ (75W) Isolated Module 1 21V 56V 3.3V 15A 50W 3 kV ITE (Commercial) OCP, OTP, OVP, SCP -25°C ~ 85°C 90% Through Hole Full Brick 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580

Substitute Part Grouping Explanation

Substitute part selection is based strictly on the following key parameters: manufacturer part number, input voltage range (21V–56V), output voltage (3.3V), output current rating (15A), power rating (50W), isolation voltage (3 kV), series (VI-200™), mounting type (Through Hole), mechanical package (Full Brick), electrical features (OCP, OTP, OVP, SCP), operating temperature (-25°C ~ 85°C), application (ITE Commercial), RoHS status, and efficiency. Only parts matching all specified technical and compliance characteristics are considered substitutes.

Parameter Comparison

Parameter VI-22Y-CX VI-22Y-CX-B1
Manufacturer Part Number VI-22Y-CX VI-22Y-CX-B1
Series VI-200™ (75W) VI-200™ (75W)
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 21V 21V
Voltage - Input (Max) 56V 56V
Voltage - Output 1 3.3V 3.3V
Current - Output (Max) 15A 15A
Power (Watts) 50W 50W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial) ITE (Commercial)
Features OCP, OTP, OVP, SCP OCP, OTP, OVP, SCP
Operating Temperature -25°C ~ 85°C -25°C ~ 85°C
Efficiency 90% 90%
Mounting Type Through Hole Through Hole
Package / Case Full Brick Full Brick
Size / Dimension 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm)
RoHS Status RoHS non-compliant RoHS non-compliant
MSL Not Applicable Not Applicable
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

The main part number VI-22Y-CX is obsolete, while the substitute VI-22Y-CX-B1 is active. Both parts are RoHS non-compliant and have identical compliance status (REACH Unaffected, ECCN EAR99, HTSUS 8504.40.9580). Selection should be based on product availability and identical compliance profiles. Size/dimension differences must be evaluated for mechanical compatibility in existing designs.

Frequently Asked Questions (FAQ)

Q1: What substitution criteria are applied for DC-DC converter modules VI-22Y-CX and VI-22Y-CX-B1?
Substitution is determined by identical electrical specifications (input and output voltages, current, power, isolation), series, application type, features, operating temperature range, mounting type, package format, compliance and inventory status.

Q2: Are VI-22Y-CX and VI-22Y-CX-B1 mechanically interchangeable?
Both use Full Brick packages; however, physical height differs: VI-22Y-CX is 0.50" high; VI-22Y-CX-B1 is 1.07" high. Dimensional differences should be verified for physical fit within the application.

Q3: Is the substitute part RoHS compliant or has different environmental certifications?
Both VI-22Y-CX and VI-22Y-CX-B1 are RoHS non-compliant and REACH Unaffected, with matching ECCN and HTSUS codes.

Q4: Does the substitute part maintain the same electrical performance as the main part?
Electrical performance parameters including input voltage range, output voltage, output current, power rating, isolation voltage, and features are identical across both part numbers.

Q5: What should be considered for mounting and assembly?
Both parts use Through Hole mounting in a Full Brick package. Review height and size for compatibility with existing PCBs and mechanical fixtures.

Request Quote (Ships tomorrow)