VI-22X-EW Equivalent & Substitute Parts Reference

Part Overview

The Vicor Corporation VI-22X-EW is a DC DC converter classified as an Isolated Module providing a single 5.2V output at up to 19.23A from a 21V to 56V input, with a maximum output power of 100W. The VI-22X-EW is a full brick module designed for ITE (Commercial) applications, incorporating protection features such as OCP, OTP, OVP, and SCP. The product status is Obsolete. Sourcing alternatives with matching electrical and mechanical parameters is essential for new designs or maintenance, especially due to obsolescence.

Substiute Parts

VI-22X-EW
Vicor CorporationIn Stock: 820VI-22X-EW Datasheet
VI-22X-EW
Current Part
VI-22X-EW-B1
Vicor CorporationIn Stock: 756VI-22X-EW-B1 Datasheet
VI-22X-EW-B1
Similar

Key Parameters

ParameterValue
Manufacturer Part NumberVI-22X-EW
ManufacturerVicor Corporation
Category
DescriptionDC DC CONVERTER 5.2V 100W
TypeIsolated Module
SeriesVI-200™ (100W)
Number of Outputs1
Voltage - Input (Min)21V
Voltage - Input (Max)56V
Voltage - Output 15.2V
Current - Output (Max)19.23A
Power (Watts)100 W
Voltage - Isolation3 kV
ApplicationsITE (Commercial)
FeaturesOCP, OTP, OVP, SCP
Operating Temperature-10°C ~ 85°C
Efficiency88%
Mounting TypeThrough Hole
Package / CaseFull Brick
Size / Dimension4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm)
RoHS StatusRoHS non-compliant
REACH StatusREACH Unaffected
Moisture Sensitivity Level (MSL)Not Applicable
ECCNEAR99
HTSUS8504.40.9580

Substitute Part Grouping Explanation

Substitute parts for the VI-22X-EW are determined based on identical or equivalent electrical parameters, mechanical package, mounting type, protection features, certifications, and compliance status. Substitution is accepted when input and output voltages, currents, power rating, isolation voltage, efficiency, thermal range, and protection features match exactly. Compliance with the same RoHS and REACH status, mounting method, form factor, and use in the same application area are required for direct substitution.

Key parameters for substitution:

  • Input Voltage Range: 21V to 56V
  • Output Voltage: 5.2V
  • Output Current (Max): 19.23A
  • Power (Watts): 100W
  • Isolation Voltage: 3kV
  • Protection Features: OCP, OTP, OVP, SCP
  • Package/Case: Full Brick
  • Mounting Type: Through Hole
  • Operating Temperature Range: -10°C ~ 85°C
  • Efficiency: 88%
  • Compliance and Certification status (RoHS, REACH)

Parameter Comparison

Parameter VI-22X-EW VI-22X-EW-B1
Manufacturer Vicor Corporation Vicor Corporation
Series VI-200™ (100W) VI-200™ (100W)
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 21V 21V
Voltage - Input (Max) 56V 56V
Voltage - Output 1 5.2V 5.2V
Current - Output (Max) 19.23A 19.23A
Power (Watts) 100 W 100 W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial) ITE (Commercial)
Features OCP, OTP, OVP, SCP OCP, OTP, OVP, SCP
Operating Temperature -10°C ~ 85°C -10°C ~ 85°C
Efficiency 88% 88%
Mounting Type Through Hole Through Hole
Package / Case Full Brick Full Brick
Size / Dimension 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm)
RoHS Status RoHS non-compliant RoHS non-compliant
REACH Status REACH Unaffected REACH Unaffected
Moisture Sensitivity Level (MSL) Not Applicable Not Applicable
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

The VI-22X-EW is classified as obsolete. When selecting a substitute, ensure that the product status aligns with current sourcing requirements. Both VI-22X-EW and VI-22X-EW-B1 are RoHS non-compliant, have REACH Unaffected status, and share the same ECCN and HTSUS classifications. The substitute VI-22X-EW-B1 matches the main part in all major electrical parameters, mounting type, thermal range, and package type, with a noted difference in module height. Use the substitute only if the height difference is compatible with the end-application mechanical constraints.

Frequently Asked Questions (FAQ)

Q1: What are the primary criteria for substituting VI-22X-EW in a design?
A1: The primary substitution criteria are matching input voltage range, output voltage and current ratings, power, isolation voltage, efficiency, package type, mounting method, operating temperature, and compliance certifications such as RoHS, REACH, ECCN, and HTSUS.

Q2: Are there mechanical differences between VI-22X-EW and VI-22X-EW-B1?
A2: Both parts have the same length and width, but the VI-22X-EW-B1 has a greater height: 1.07" compared to 0.50" for the main part.

Q3: Does RoHS or REACH compliance affect substitution?
A3: Both the main and substitute parts are RoHS non-compliant and REACH Unaffected, so compliance status does not affect substitution between these two specific models.

Q4: Is the through-hole mounting and full brick package consistent across substitute options?
A4: Yes, both VI-22X-EW and VI-22X-EW-B1 share through-hole mounting and full brick module package.

Q5: What applications are supported by both VI-22X-EW and VI-22X-EW-B1?
A5: Both parts are classified for ITE (Commercial) applications as per provided documentation.

Q6: How significant is the efficiency parameter for substitutes?
A6: Both main and substitute parts have matched efficiency at 88%; this parameter does not differentiate them.

Q7: Can substitute selection be based on product status only?
A7: Product status (active or obsolete) informs sourcing and design in considerations in addition to technical parameters and compliance information.

Request Quote (Ships tomorrow)