Equivalent & Substitute Parts Reference: Vicor VI-22R-CX

Part Overview

The Vicor VI-22R-CX is an isolated module DC-DC converter designed for ITE (Commercial) applications. It features a single 7.5V output at up to 10A, with an input voltage range of 21V to 56V and a maximum output power of 75W. This model is part of the VI-200™ (75W) series. The product is currently obsolete, necessitating the identification of alternative models for ongoing designs, maintenance, or replacement in existing systems.

Substiute Parts

VI-22R-CX
Vicor CorporationIn Stock: 1169VI-22R-CX Datasheet
VI-22R-CX
Current Part
VI-22R-CX-B1
Vicor CorporationIn Stock: 933VI-22R-CX-B1 Datasheet
VI-22R-CX-B1
Similar

Key Parameters

Manufacturer Part Number Manufacturer Series Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status MSL REACH Status ECCN HTSUS
VI-22R-CX Vicor Corporation VI-200™ (75W) Isolated Module 1 21V 56V 7.5V 10A 75 W 3 kV ITE (Commercial) OCP, OTP, OVP, SCP -25°C ~ 85°C 90% Through Hole Full Brick 4.60" x 2.40" x 0.50" RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580

Substitute Part Grouping Explanation

Substitution within the isolated DC-DC converter category is guided by alignment on key electrical and mechanical parameters. Parameters used for substitution include series, input and output voltage range, output current, output power, isolation voltage, mounting, package type, dimensions, product compliance, and features. Only parts matching these strict criteria are considered acceptable substitutes in this context.

Key parameters used for substitution:

  • Series
  • Input Voltage Range (Min/Max)
  • Output Voltage and Current
  • Maximum Power Rating
  • Isolation Voltage
  • Applications
  • Features
  • Operating Temperature Range
  • Efficiency
  • Mounting Type
  • Package / Case
  • Size / Dimension
  • Compliance Status (RoHS, REACH)
  • Product Regulatory Identifiers (ECCN, HTSUS)

Parameter Comparison

Parameter Main Part: VI-22R-CX Substitute: VI-22R-CX-B1
Manufacturer Vicor Corporation Vicor Corporation
Series VI-200™ (75W) VI-200™ (75W)
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 21V 21V
Voltage - Input (Max) 56V 56V
Voltage - Output 1 7.5V 7.5V
Current - Output (Max) 10A 10A
Power (Watts) 75 W 75 W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial) ITE (Commercial)
Features OCP, OTP, OVP, SCP OCP, OTP, OVP, SCP
Operating Temperature -25°C ~ 85°C -25°C ~ 85°C
Efficiency 90% 90%
Mounting Type Through Hole Through Hole
Package / Case Full Brick Full Brick
Size / Dimension 4.60" x 2.40" x 0.50" 4.60" x 2.40" x 1.07"
RoHS Status RoHS non-compliant RoHS non-compliant
MSL Not Applicable Not Applicable
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

The main part, VI-22R-CX, has an obsolete product status. The substitute, VI-22R-CX-B1, is active with compatible electrical, mechanical, and environmental specifications. Both parts are RoHS non-compliant and share the same REACH status and regulatory classification. Selection should be based on product lifecycle status and inventory availability.

Frequently Asked Questions (FAQ)

Q1: What parameters must match to substitute a Vicor VI-22R-CX DC-DC converter?
A1: Substitute selection requires matching input voltage range, output voltage, output current, power rating, isolation voltage, features, package type, mounting method, dimensions, and compliance status.

Q2: Are there any differences in mechanical dimensions between VI-22R-CX and VI-22R-CX-B1?
A2: Both are full brick packages with identical length and width (4.60" x 2.40"). The height differs: VI-22R-CX is 0.50" high, while VI-22R-CX-B1 is 1.07" high.

Q3: Do both parts meet the same environmental and regulatory standards?
A3: Both parts are RoHS non-compliant, REACH unaffected, and share the same ECCN (EAR99) and HTSUS (8504.40.9580) classifications.

Q4: Can VI-22R-CX-B1 be directly used in place of VI-22R-CX in an existing design?
A4: All electrical parameters and mounting type match. Mechanical height difference should be reviewed for enclosure or spacing compatibility.

Q5: What product status differences exist between the two parts?
A5: VI-22R-CX is obsolete. VI-22R-CX-B1 is active and available for ongoing procurement.

Request Quote (Ships tomorrow)