Request Quote
(Ships tomorrow)
Vicor VI-22P-CX Equivalent & Substitute DC-DC Converter Reference
Part Overview
The Vicor VI-22P-CX is an obsolete Isolated Module DC-DC converter, offering a single 13.8V output at up to 5.43A with a wide 21V to 56V DC input range and 75W maximum power. It operates with high efficiency (90%) and provides enhanced protection features such as overcurrent protection (OCP), overtemperature protection (OTP), overvoltage protection (OVP), and short-circuit protection (SCP). As a full brick through-hole module, it is designed for ITE (Commercial) applications and is RoHS non-compliant. The discontinued status necessitates identifying directly substitutable parts matching all critical electrical and mechanical characteristics.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Description | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-22P-CX | Vicor Corporation | DC DC CONVERTER 13.8V 75W | VI-200™ (75W) | Obsolete | Isolated Module | 1 | 21V | 56V | 13.8V | 5.43A | 75 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution is based strictly on matching key electrical and mechanical parameters. Substitute DC-DC converter modules must have:
- Identical input voltage range (21V - 56V)
- Same output voltage (13.8V) and maximum current rating (5.43A)
- Equal or higher power rating (75 W)
- Equivalent isolation voltage (3 kV)
- Same protection features (OCP, OTP, OVP, SCP)
- Matching operating temperature range (-25°C ~ 85°C)
- Same efficiency (90%)
- Identical mounting type (Through Hole) and package/case (Full Brick) with similar size/dimension
- Same RoHS and REACH compliance statuses
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Description | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-22P-CX | Vicor Corporation | DC DC CONVERTER 13.8V 75W | VI-200™ (75W) | Obsolete | Isolated Module | 1 | 21V | 56V | 13.8V | 5.43A | 75 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
| VI-22P-CX-B1 | Vicor Corporation | DC DC CONVERTER 13.8V 75W | VI-200™ (75W) | Active | Isolated Module | 1 | 21V | 56V | 13.8V | 5.43A | 75 W | 3 kV | ITE (Commercial) | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
Both Vicor VI-22P-CX and VI-22P-CX-B1 meet identical key electrical and mechanical specifications. The VI-22P-CX-B1 is the recommended substitute as it is active and directly replaces the obsolete VI-22P-CX without altering compliance, RoHS status, Inventory/HTSUS/ECCN codes, or mechanical format except for an increased height. There are no differences in product certifications or regulatory status.
Frequently Asked Questions (FAQ)
Q1: How is compatibility determined for the Vicor VI-22P-CX and its substitutes?
Compatibility is determined by matching all provided electrical parameters (input range, output voltage/current, power, isolation), thermal range, features, and mechanical characteristics.
Q2: Are the VI-22P-CX and VI-22P-CX-B1 mechanically interchangeable?
Both parts use the same full brick package; the only dimensional difference is increased height in the VI-22P-CX-B1 (1.07" vs. 0.50"). Mechanical fit must be considered with respect to available PCB and enclosure height.
Q3: Are there differences in certifications or statuses (RoHS, REACH, ECCN, HTSUS) between main and substitute parts?
No. Both parts share identical compliance designations and regulatory codes as provided.
Q4: Can the VI-22P-CX-B1 be directly substituted in existing designs using VI-22P-CX?
All provided key electrical parameters and mounting methods are identical, supporting direct substitution where height increase does not impact mechanical allowances.
Q5: What protection features are maintained in the substitute model?
Both the VI-22P-CX and VI-22P-CX-B1 include OCP, OTP, OVP, and SCP as standard features.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts