Request Quote
(Ships tomorrow)
Vicor VI-22M-EX Equivalent & Substitute Parts Reference
Part Overview
The Vicor VI-22M-EX is an isolated DC-DC converter module with a single output of 10V at up to 7.5A, supporting a 21V to 56V input range and delivering up to 75W. It features overcurrent, overtemperature, overvoltage, and short-circuit protection and is primarily used in ITE (Commercial) applications. The VI-22M-EX is now classified as obsolete, making it necessary to identify alternative models strictly matching its key electrical, mechanical, and compliance specifications for direct substitution in existing designs.
Substiute Parts
Key Parameters
| Parameter | VI-22M-EX Value |
|---|---|
| Manufacturer | Vicor Corporation |
| Series | VI-200™ (75W) |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 21V |
| Voltage - Input (Max) | 56V |
| Voltage - Output 1 | 10V |
| Current - Output (Max) | 7.5A |
| Power (Watts) | 75 W |
| Voltage - Isolation | 3 kV |
| Efficiency | 88% |
| Operating Temperature | -10°C ~ 85°C |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) |
| Features | OCP, OTP, OVP, SCP |
| RoHS Status | RoHS non-compliant |
| REACH Status | REACH Unaffected |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution for the Vicor VI-22M-EX is determined by strict matching of electrical and mechanical parameters, including: manufacturer, series, type, number of outputs, input voltage range, output voltage, maximum output current, power rating, isolation voltage, efficiency, operating temperature range, mounting type, package, dimensions, protection features, RoHS and REACH status, and product status. Only parts where all these specifications are directly equivalent are included as substitutes.
Parameter Comparison
| Parameter | VI-22M-EX | VI-22M-EX-B1 |
|---|---|---|
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VI-200™ (75W) | VI-200™ (75W) |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 21V | 21V |
| Voltage - Input (Max) | 56V | 56V |
| Voltage - Output 1 | 10V | 10V |
| Current - Output (Max) | 7.5A | 7.5A |
| Power (Watts) | 75 W | 75 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Efficiency | 88% | 88% |
| Operating Temperature | -10°C ~ 85°C | -10°C ~ 85°C |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) | 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
When selecting a substitute for the Vicor VI-22M-EX DC-DC converter module, evaluate product status, RoHS and REACH compliance, and inventory status. The VI-22M-EX is obsolete, while the VI-22M-EX-B1 is active and shares equivalent compliance and certification characteristics. Mechanical dimensions should be reviewed to ensure suitability for the application due to height variation.
Frequently Asked Questions (FAQ)
Q1: What parameters must match for direct substitution of a DC-DC converter module?
A1: Key parameters include input voltage range, output voltage, maximum output current, power rating, isolation voltage, features, efficiency, operating temperature, package type, mounting, size, and compliance status (RoHS, REACH).
Q2: Are the VI-22M-EX and VI-22M-EX-B1 mechanically identical?
A2: Both parts share identical length and width, but the VI-22M-EX-B1 is taller (1.07" vs 0.50"). Mechanical fit must be confirmed for the intended application.
Q3: Do both parts have matching certifications?
A3: Both the VI-22M-EX and VI-22M-EX-B1 are RoHS non-compliant and REACH unaffected.
Q4: Is the VI-22M-EX-B1 a drop-in replacement for the VI-22M-EX?
A4: The VI-22M-EX-B1 matches all electrical, protection, and compliance parameters. Mechanical compatibility should be verified due to the difference in height.
Q5: Why is substitution necessary for the VI-22M-EX?
A5: Substitution is required due to the obsolete product status of the VI-22M-EX. Active equivalents with matching parameters are required for ongoing designs and maintenance.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts