Equivalent & Substitute Parts for Vicor Corporation VI-22J-EX

Part Overview

The Vicor Corporation VI-22J-EX is an isolated module DC-DC converter designed for ITE (Commercial) applications. It provides a single 36V output at up to 2.08A from a 21V–56V input voltage range, delivering 75W of output power in a full brick package. The module features over-current protection (OCP), over-temperature protection (OTP), over-voltage protection (OVP), and short-circuit protection (SCP), and it is specified with a 3 kV isolation voltage. The VI-22J-EX is classified as Obsolete, making it essential to identify strictly comparable substitute parts for design continuity, repair, or ongoing manufacturing support.

Substiute Parts

VI-22J-EX
Vicor CorporationIn Stock: 879VI-22J-EX Datasheet
VI-22J-EX
Current Part
VI-22J-EX-B1
Vicor CorporationIn Stock: 1127VI-22J-EX-B1 Datasheet
VI-22J-EX-B1
Similar

Key Parameters

Parameter Value
Manufacturer Part Number VI-22J-EX
Manufacturer Vicor Corporation
Description DC DC CONVERTER 36V 75W
Type Isolated Module
Number of Outputs 1
Voltage - Input (Min) 21V
Voltage - Input (Max) 56V
Voltage - Output 1 36V
Current - Output (Max) 2.08A
Power (Watts) 75 W
Voltage - Isolation 3 kV
Applications ITE (Commercial)
Features OCP, OTP, OVP, SCP
Operating Temperature -10°C ~ 85°C
Efficiency 88%
Mounting Type Through Hole
Package / Case Full Brick
Size / Dimension 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm)
RoHS Status RoHS non-compliant
Product Status Obsolete
Series VI-200™ (75W)

Substitute Part Grouping Explanation

Substitution is based strictly on parity in the following key electrical and mechanical parameters: input voltage range, output voltage and current ratings, power rating, isolation voltage, features, efficiency, operating temperature, mounting type, and package/case dimensions. All parameters must match exactly or be equivalent as specified for the full brick format and electrical compliance within the VI-200™ (75W) series. Only parts meeting these documented criteria are considered suitable substitutes.

Key parameters used for grouping:

  • Voltage - Input (Min/Max)
  • Voltage - Output 1
  • Current - Output (Max)
  • Power (Watts)
  • Voltage - Isolation
  • Features (OCP, OTP, OVP, SCP)
  • Operating Temperature
  • Efficiency
  • Mounting Type
  • Package / Case
  • Size / Dimension
  • RoHS Status

Parameter Comparison

Parameter Main Part: VI-22J-EX Substitute: VI-22J-EX-B1
Manufacturer Vicor Corporation Vicor Corporation
Description DC DC CONVERTER 36V 75W DC DC CONVERTER 36V 75W
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 21V 21V
Voltage - Input (Max) 56V 56V
Voltage - Output 1 36V 36V
Current - Output (Max) 2.08A 2.08A
Power (Watts) 75 W 75 W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial) ITE (Commercial)
Features OCP, OTP, OVP, SCP OCP, OTP, OVP, SCP
Operating Temperature -10°C ~ 85°C -10°C ~ 85°C
Efficiency 88% 88%
Mounting Type Through Hole Through Hole
Package / Case Full Brick Full Brick
Size / Dimension 4.60" L x 2.40" W x 0.50" H
(116.8mm x 61.0mm x 12.7mm)
4.60" L x 2.40" W x 1.07" H
(116.8mm x 61.0mm x 27.1mm)
RoHS Status RoHS non-compliant RoHS non-compliant
Product Status Obsolete Active
Series VI-200™ (75W) VI-200™ (75W)

Engineering Selection Recommendations

Selection between VI-22J-EX and VI-22J-EX-B1 should be based on product lifecycle status, compliance, and availability. VI-22J-EX is listed as Obsolete, whereas VI-22J-EX-B1 is listed as Active. Both parts are RoHS non-compliant. There is no difference in moisture sensitivity or REACH status. ECCN and HTSUS are identical.

Frequently Asked Questions (FAQ)

Q1: What are the key criteria for substituting VI-22J-EX with VI-22J-EX-B1?
A1: Electric and mechanical parameters including input voltage range, output voltage, output current, power, isolation voltage, features, efficiency, package type, mounting style, and series must match for direct substitution.

Q2: Is the form factor equivalent between VI-22J-EX and VI-22J-EX-B1?
A2: Both use a full brick package with the same length and width. Only the height differs (0.50" for VI-22J-EX and 1.07" for VI-22J-EX-B1).

Q3: Are there any differences in environmental or compliance status?
A3: Both are RoHS non-compliant and REACH unaffected. Both share the same ECCN and HTSUS codes.

Q4: Will the mounting method change when using VI-22J-EX-B1?
A4: Both have through-hole mounting; no change in board-level mounting requirements.

Q5: Does the product status affect long-term availability?
A5: VI-22J-EX is Obsolete; VI-22J-EX-B1 is Active. Selection should be based on the required product status for procurement and supply chain management.

Q6: Are electrical protections (OCP, OTP, OVP, SCP) consistent between the parts?
A6: Both have identical protection features as explicitly specified.

Request Quote (Ships tomorrow)