Vicor VI-22J-CX Equivalent & Substitute Parts Reference

Part Overview

The Vicor VI-22J-CX is an isolated module DC-DC converter from the VI-200™ (75W) series. It provides 1 output at 36V and up to 2.08A from a 21V to 56V input, featuring OCP, OTP, OVP, and SCP protections and mounting as a full brick through-hole package. The product is listed as obsolete, necessitating identification and selection of substitute parts for ongoing designs and maintenance where exact electrical and mechanical compatibility is required.

Substiute Parts

VI-22J-CX
Vicor CorporationIn Stock: 949VI-22J-CX Datasheet
VI-22J-CX
Current Part
VI-22J-CX-B1
Vicor CorporationIn Stock: 1103VI-22J-CX-B1 Datasheet
VI-22J-CX-B1
Similar

Key Parameters

ParameterValue
ManufacturerVicor Corporation
SeriesVI-200™ (75W)
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)21V
Voltage - Input (Max)56V
Voltage - Output 136V
Current - Output (Max)2.08A
Power (Watts)75W
Voltage - Isolation3 kV
FeaturesOCP, OTP, OVP, SCP
Operating Temperature-25°C ~ 85°C
Efficiency90%
Mounting TypeThrough Hole
Package / CaseFull Brick
Size / Dimension4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm)
RoHS StatusRoHS non-compliant
REACH StatusREACH Unaffected
ECCNEAR99
HTSUS8504.40.9580

Substitute Part Grouping Explanation

Substitution is strictly based on matching the key electrical and mechanical parameters defined for isolated module DC-DC converters. Substitutes must match or exceed the following criteria:

  • Series: VI-200™ (75W)
  • Manufacturer: Vicor Corporation
  • Type: Isolated Module
  • Number of Outputs: 1
  • Input Voltage Range: 21V to 56V
  • Output Voltage: 36V
  • Output Current: 2.08A
  • Power Rating: 75W
  • Isolation Voltage: 3 kV
  • Features: OCP, OTP, OVP, SCP
  • Operating Temperature: -25°C ~ 85°C
  • Efficiency: 90%
  • Mounting Type: Through Hole
  • Package / Case: Full Brick Substitute selection further considers product status and compliance fields as provided.

Parameter Comparison

Parameter Main Part (VI-22J-CX) Substitute Part (VI-22J-CX-B1)
Manufacturer Vicor Corporation Vicor Corporation
Series VI-200™ (75W) VI-200™ (75W)
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 21V 21V
Voltage - Input (Max) 56V 56V
Voltage - Output 1 36V 36V
Current - Output (Max) 2.08A 2.08A
Power (Watts) 75W 75W
Voltage - Isolation 3 kV 3 kV
Features OCP, OTP, OVP, SCP OCP, OTP, OVP, SCP
Operating Temperature -25°C ~ 85°C -25°C ~ 85°C
Efficiency 90% 90%
Mounting Type Through Hole Through Hole
Package / Case Full Brick Full Brick
Size / Dimension 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm)
RoHS Status RoHS non-compliant RoHS non-compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580
Product Status Obsolete Active

Engineering Selection Recommendations

Based on product status, the VI-22J-CX is obsolete, while the VI-22J-CX-B1 is active. Both share identical electrical and most mechanical parameters, differing only by the height dimension of the full brick package. RoHS and REACH statuses match, with both products being RoHS non-compliant and REACH unaffected. For applications requiring active parts or long-term availability within these compliance constraints, select the VI-22J-CX-B1.

Frequently Asked Questions (FAQ)

Q1: What substitution criteria are used for Vicor VI-22J-CX?
Substitution is determined by matching input voltage range, output voltage and current, power rating, isolation voltage, features, mounting type, package/case, operating temperature, efficiency, and compliance status.

Q2: Is VI-22J-CX-B1 a direct form-fit-function replacement?
VI-22J-CX-B1 matches the main electrical specifications and mounting type. The physical dimensions differ only in height (1.07" vs. 0.50"). Application fit must consider this dimension when designing or retrofitting assemblies.

Q3: Are there compliance differences to consider?
Both the main and substitute parts are RoHS non-compliant and REACH unaffected. Selection does not result in different regulatory requirements.

Q4: Is the package form (Full Brick) compatible across substitutes?
Both VI-22J-CX and VI-22J-CX-B1 use the full brick package style and through-hole mounting. Ensure sufficient clearance for height in the assembly when using VI-22J-CX-B1.

Q5: What key parameter differences exist between main and substitute models?
All electrical characteristics align. The only mechanical difference is the height of the package. Verification of mechanical space prior to substitution is necessary.

Request Quote (Ships tomorrow)