Part Overview
Vicor VI-21R-CX is an isolated DC DC converter module designed for ITE (Commercial) applications, providing a single output of 7.5V at up to 10A current and rated for 75W output power. With a full brick package and through-hole mounting, the module offers input voltage range from 21V to 32V, 3 kV isolation, and features including OCP, OTP, OVP, and SCP. The VI-21R-CX is classified as obsolete, making it necessary to select substitute or equivalent models matching the required application parameters.
Substiute Parts
Key Parameters
| Parameter | Main Part Value |
|---|---|
| Manufacturer Part Number | VI-21R-CX |
| Manufacturer | Vicor Corporation |
| Series | VI-200™ (75W) |
| Product Status | Obsolete |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 21V |
| Voltage - Input (Max) | 32V |
| Voltage - Output 1 | 7.5V |
| Current - Output (Max) | 10A |
| Power (Watts) | 75 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP |
| Operating Temperature | -25°C ~ 85°C |
| Efficiency | 90% |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H |
| RoHS Status | RoHS non-compliant |
| MSL | Not Applicable |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution is based strictly on matching electrical and mechanical parameters: input voltage range, output voltage, maximum output current, output power rating, isolation voltage, module type, mounting method, package dimensions, operating temperature range, series, feature set, efficiency, and application category. Compliance and certification statuses such as RoHS, REACH, ECCN, and HTSUS are also considered, as is the obsolete status of the original part.
Parameter Comparison
| Parameter | VI-21R-CX | VI-21R-CX-B1 |
|---|---|---|
| Manufacturer Part Number | VI-21R-CX | VI-21R-CX-B1 |
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VI-200™ (75W) | VI-200™ (75W) |
| Product Status | Obsolete | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 21V | 21V |
| Voltage - Input (Max) | 32V | 32V |
| Voltage - Output 1 | 7.5V | 7.5V |
| Current - Output (Max) | 10A | 10A |
| Power (Watts) | 75 W | 75 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| Operating Temperature | -25°C ~ 85°C | -25°C ~ 85°C |
| Efficiency | 90% | 90% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H | 4.60" L x 2.40" W x 1.07" H |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| MSL | Not Applicable | Not Applicable |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
Selection between Vicor VI-21R-CX and VI-21R-CX-B1 must be based on product status, compliance declarations, and inventory. VI-21R-CX is obsolete, while VI-21R-CX-B1 is active and available. Both parts are RoHS non-compliant and share the same REACH, ECCN, and HTSUS status, ensuring identical certification characteristics.
Frequently Asked Questions (FAQ)
Q1: What parameters must match for a DC DC converter module to be substituted in this application?
A1: Key substitution parameters include input voltage range, output voltage, output current rating, output power, isolation voltage, module type, mounting type, package dimensions, operating temperature range, feature set, and application category.
Q2: Can the Vicor VI-21R-CX-B1 directly replace VI-21R-CX in the same slot?
A2: Both parts share all critical electrical parameters and mounting type; however, the VI-21R-CX-B1 has a different height dimension (1.07" vs. 0.50"). Ensure mechanical fit in the target system.
Q3: Are there compliance differences between VI-21R-CX and VI-21R-CX-B1?
A3: Both modules are RoHS non-compliant and REACH unaffected, with identical ECCN and HTSUS codes.
Q4: What certification statuses must be checked before substituting DC DC converter modules?
A4: ECCN, HTSUS, RoHS, and REACH status should match project requirements and be consistent between original and substitute parts.
Q5: Why is locating an equivalent part necessary for VI-21R-CX?
A5: The VI-21R-CX is obsolete, making ongoing procurement and long-term support dependent on selecting an active substitute with matching specifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts