Request Quote
(Ships tomorrow)
Vicor VI-20T-CY Equivalent & Substitute Parts Reference
Part Overview
The Vicor VI-20T-CY is a DC-DC converter designed as an isolated module providing one output of 6.5V at up to 7.69A with a power rating of 50W. It accepts an input voltage range of 10V to 20V and offers 3 kV isolation, primarily for ITE (commercial) applications. The product is classified as obsolete, requiring identification of direct alternative models for ongoing maintenance, approved repair, or qualified design continuation.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | VI-20T-CY |
| Series | VI-200™ (50W) |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 10V |
| Voltage - Input (Max) | 20V |
| Voltage - Output 1 | 6.5V |
| Current - Output (Max) | 7.69A |
| Power (Watts) | 50 W |
| Voltage - Isolation | 3 kV |
| Features | OCP, OTP, OVP, SCP |
| Operating Temperature | -25°C ~ 85°C |
| Efficiency | 90% |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) |
| RoHS Status | RoHS non-compliant |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution is based strictly on matching all electrical, mechanical, and certification parameters as provided. Only parts with identical or matching values for the following parameters are considered suitable substitutes:
- Input voltage range (10V ~ 20V)
- Output voltage (6.5V)
- Maximum output current (7.69A)
- Power rating (50W)
- Isolation voltage (3 kV)
- Output count (1)
- Protection features (OCP, OTP, OVP, SCP)
- Operating temperature range (-25°C ~ 85°C)
- Efficiency (90%)
- Mounting type (Through Hole)
- Package / case (Full Brick)
- RoHS and REACH compliance Only models with matching or explicitly listed compatible dimensions and certifications are included.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Series | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VI-20T-CY | Vicor Corporation | VI-200™ (50W) | Isolated Module | 1 | 10V | 20V | 6.5V | 7.69A | 50 W | 3 kV | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) | RoHS non-compliant | REACH Unaffected | EAR99 | 8504.40.9580 |
| VI-20T-CY-F1 | Vicor Corporation | VI-200™ (50W) | Isolated Module | 1 | 10V | 20V | 6.5V | 7.69A | 50 W | 3 kV | OCP, OTP, OVP, SCP | -25°C ~ 85°C | 90% | Through Hole | Full Brick | 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) | RoHS non-compliant | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
Selection should prioritize parts with identical series, electrical performance, mechanical mounting, and certified regulatory status as the original Vicor VI-20T-CY. As the VI-20T-CY is obsolete, the Vicor VI-20T-CY-F1 meets all electrical, environmental, and certification parameters provided, while offering a variant in package dimensions. Both models hold a RoHS non-compliant status and are unaffected by REACH, holding the same ECCN and HTSUS designations.
Frequently Asked Questions (FAQ)
Q1: Are the VI-20T-CY and VI-20T-CY-F1 DC-DC converters electrically identical?
A1: Yes, both parts share identical input voltage range, output voltage, maximum output current, power rating, isolation voltage, efficiency, and protection features.
Q2: Can the Vicor VI-20T-CY-F1 directly replace the Vicor VI-20T-CY in an assembly?
A2: The Vicor VI-20T-CY-F1 can be considered a substitute based solely on matching electrical parameters and operational features. Mechanical fit should be checked using the provided package and dimensional data.
Q3: Is there any difference in regulatory compliance between these models?
A3: Both parts are RoHS non-compliant, REACH unaffected, and share the same ECCN and HTSUS codes.
Q4: What package differences exist between the VI-20T-CY and VI-20T-CY-F1?
A4: VI-20T-CY measures 4.60" x 2.40" x 0.50" (116.8mm x 61.0mm x 12.7mm), while VI-20T-CY-F1 measures 4.60" x 1.86" x 0.79" (116.8mm x 47.2mm x 20.1mm).
Q5: Do the substitute models affect RoHS or REACH compliance of the end product?
A5: Both are RoHS non-compliant and REACH unaffected, resulting in no change in overall product compliance status based on this substitution.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts