Part Overview
The Vicor VI-20D-EX is an isolated module DC-DC converter, designed for commercial ITE applications with a single output of 85V at up to 882mA. This module offers features such as overcurrent protection (OCP), overtemperature protection (OTP), overvoltage protection (OVP), and short circuit protection (SCP), delivering up to 75W power with an efficiency of 88%. The product status is Obsolete, requiring identification of alternative or equivalent models to support ongoing applications or replacements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | VI-20D-EX |
| Manufacturer | Vicor Corporation |
| Series | VI-200™ (75W) |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 10V |
| Voltage - Input (Max) | 20V |
| Voltage - Output 1 | 85V |
| Current - Output (Max) | 882mA |
| Power (Watts) | 75 W |
| Voltage - Isolation | 3 kV |
| Features | OCP, OTP, OVP, SCP |
| Operating Temperature | -10°C ~ 85°C |
| Efficiency | 88% |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H |
| RoHS Status | RoHS non-compliant |
| MSL | Not Applicable |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitute parts for DC-DC converters in isolated module form must match critical electrical and mechanical parameters. The key substitution criteria are: input voltage range, output voltage, output current, power rating, isolation voltage, protection features, mounting type, package/case, operating temperature range, and product status. Only parts matching all these parameters can be considered direct substitutes.
Parameter Comparison
| Parameter | Main Part: VI-20D-EX | Substitute: VI-20D-EX-F1 |
|---|---|---|
| Manufacturer Part Number | VI-20D-EX | VI-20D-EX-F1 |
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VI-200™ (75W) | VI-200™ (75W) |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 10V | 10V |
| Voltage - Input (Max) | 20V | 20V |
| Voltage - Output 1 | 85V | 85V |
| Current - Output (Max) | 882mA | 882mA |
| Power (Watts) | 75 W | 75 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| Operating Temperature | -10°C ~ 85°C | -10°C ~ 85°C |
| Efficiency | 88% | 88% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H | 4.60" L x 1.86" W x 0.79" H |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| MSL | Not Applicable | Not Applicable |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
The main part, Vicor VI-20D-EX, is currently obsolete, necessitating substitution for ongoing maintenance or new designs. The substitute, Vicor VI-20D-EX-F1, matches all key parameters outlined, including electrical ratings, features, compliance status, and mounting type. Both parts are RoHS non-compliant, have identical REACH status, and share the same ECCN and HTSUS codes. Selection between them is based strictly on product status and stock availability; the substitute part is active.
Frequently Asked Questions (FAQ)
Q1: What are the substitution criteria for the Vicor VI-20D-EX isolated DC-DC converter?
A1: Substitution is strictly based on matching input voltage range, output voltage, output current, power rating, isolation voltage, protection features, mounting type, package/case, and operating temperature. Compliance parameters and product status are also considered.
Q2: Are the mechanical dimensions identical between VI-20D-EX and VI-20D-EX-F1?
A2: The overall length is the same, but width and height differ. Confirm fit within the intended design footprint by referencing provided size/dimension parameters.
Q3: Is RoHS compliance different between the main and substitute parts?
A3: Both VI-20D-EX and VI-20D-EX-F1 are RoHS non-compliant.
Q4: What is the difference in product status between the two parts?
A4: VI-20D-EX is Obsolete; VI-20D-EX-F1 is Active.
Q5: Can protection features and performance be considered equivalent?
A5: OCP, OTP, OVP, and SCP features are identical per provided data. Efficiency and operating temperature ranges match as well.
Q6: Does the mounting type and package ensure compatibility for direct replacement?
A6: Both parts use Through Hole mounting and full brick package type. Review exact dimensions for physical fit consideration.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts