Part Overview
The VHO55-12IO7 is a single-phase SCR bridge rectifier module rated for 1.2 kV operation, manufactured by IXYS in the FO-T-A chassis mount package. This module integrates 2 SCRs and 2 diodes in a bridge configuration, designed for high-current switching applications with a maximum on-state current of 53 A (average). The product is currently obsolete, making identification of compatible substitute components essential for system maintenance and redesign applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Voltage - Off State | 1.2 kV |
| Current - On State (It (AV)) (Max) | 53 A |
| Voltage - Gate Trigger (Vgt) (Max) | 1.5 V |
| Current - Gate Trigger (Igt) (Max) | 100 mA |
| Current - Non Rep. Surge 50, 60Hz (Itsm) | 550A, 600A |
| Current - Hold (Ih) (Max) | 200 mA |
| Operating Temperature Range | -40°C ~ 125°C (TJ) |
| Mounting Type | Chassis Mount |
| Package / Case | FO-T-A |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution of the VHO55-12IO7 is determined by the following critical parameters:
- Voltage Rating: Off-state voltage must equal or exceed 1.2 kV
- Current Capacity: On-state current rating must support the application requirements
- Gate Trigger Characteristics: Vgt and Igt parameters must remain compatible with existing gate drive circuits
- Hold Current: Must not exceed 200 mA maximum
- Temperature Range: Operating range must encompass -40°C to 125°C
- Mounting Configuration: Chassis mount requirement must be maintained
- Regulatory Compliance: ROHS3 compliance and REACH unaffected status required
The MCD26-12IO1B meets the core voltage, gate trigger, hold current, temperature, mounting, and compliance requirements. However, its on-state current rating (32 A average, 50 A RMS) is lower than the VHO55-12IO7 (53 A average), reflecting a different internal structure (series connection versus bridge configuration).
Parameter Comparison
| Parameter | VHO55-12IO7 | MCD26-12IO1B |
|---|---|---|
| Manufacturer | IXYS | IXYS |
| Voltage - Off State | 1.2 kV | 1.2 kV |
| Current - On State (It (AV)) (Max) | 53 A | 32 A |
| Current - On State (It (RMS)) (Max) | — | 50 A |
| Voltage - Gate Trigger (Vgt) (Max) | 1.5 V | 1.5 V |
| Current - Gate Trigger (Igt) (Max) | 100 mA | 100 mA |
| Current - Non Rep. Surge 50, 60Hz (Itsm) | 550A, 600A | 520A, 560A |
| Current - Hold (Ih) (Max) | 200 mA | 200 mA |
| Operating Temperature | -40°C ~ 125°C (TJ) | -40°C ~ 125°C (TJ) |
| Mounting Type | Chassis Mount | Chassis Mount |
| Package / Case | FO-T-A | TO-240AA |
| Product Status | Obsolete | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
The MCD26-12IO1B is an active product from IXYS with full ROHS3 compliance and REACH unaffected status, making it suitable for applications where the VHO55-12IO7 is no longer available. Both components share identical voltage ratings, gate trigger specifications, hold current limits, and operating temperature ranges.
Selection of the MCD26-12IO1B requires verification that the reduced on-state current capacity (32 A average versus 53 A average) is acceptable for the intended application. The different internal structure (series connection versus bridge configuration) and package format (TO-240AA versus FO-T-A) necessitate mechanical and thermal design review.
Frequently Asked Questions (FAQ)
Q: Can the MCD26-12IO1B directly replace the VHO55-12IO7 in all applications?
A: Direct replacement is not guaranteed. While both components share the same 1.2 kV voltage rating and gate trigger characteristics, the MCD26-12IO1B has a lower on-state current rating (32 A average versus 53 A average). Applications requiring the full 53 A capacity must be re-evaluated. Additionally, the different package format (TO-240AA versus FO-T-A) requires mechanical redesign.
Q: What are the key electrical parameters that must match for substitution?
A: The critical parameters are off-state voltage (1.2 kV), gate trigger voltage (1.5 V maximum), gate trigger current (100 mA maximum), hold current (200 mA maximum), and operating temperature range (-40°C to 125°C). Both components meet these specifications.
Q: Are there compliance or regulatory differences between these parts?
A: Both the VHO55-12IO7 and MCD26-12IO1B are ROHS3 compliant and REACH unaffected. No regulatory barriers exist to substitution from a compliance perspective.
Q: What is the significance of the different package formats?
A: The VHO55-12IO7 uses the FO-T-A package while the MCD26-12IO1B uses TO-240AA. These are different mechanical and thermal interfaces. Thermal performance, mounting hole patterns, and lead configurations differ, requiring PCB and mechanical redesign.
Q: How do the surge current ratings compare?
A: The VHO55-12IO7 is rated for 550A (50Hz) and 600A (60Hz) non-repetitive surge current. The MCD26-12IO1B is rated for 520A (50Hz) and 560A (60Hz). Both provide adequate surge protection for typical applications, with the VHO55-12IO7 offering slightly higher surge capacity.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts