Vicor VE-JWH-EY Equivalent & Substitute Parts Reference

Part Overview

The Vicor VE-JWH-EY is an isolated DC-DC converter module designed for commercial ITE applications. It supports a single output of 52V at 962mA, 50W, and accepts a broad input voltage range from 18V to 36V. The product features overcurrent (OCP) and short-circuit protection (SCP), operates at 88% efficiency, and is supplied in a half-brick through-hole package with RoHS3 compliance. The VE-JWH-EY is marked as obsolete, necessitating the selection of equivalent or substitute models to maintain long-term system performance and supply continuity.

Substiute Parts

VE-JWH-EY
Vicor CorporationIn Stock: 821VE-JWH-EY Datasheet
VE-JWH-EY
Current Part
VE-JWH-EY-F1
Vicor CorporationIn Stock: 763VE-JWH-EY-F1 Datasheet
VE-JWH-EY-F1
Similar

Key Parameters

ParameterVE-JWH-EY
ManufacturerVicor Corporation
SeriesVE-J00™ (50W)
Product StatusObsolete
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)18V
Voltage - Input (Max)36V
Voltage - Output 152V
Current - Output (Max)962mA
Power (Watts)50W
Voltage - Isolation3kV
ApplicationsITE (Commercial)
FeaturesOCP, SCP
Operating Temperature-10°C ~ 100°C
Efficiency88%
Mounting TypeThrough Hole
Package / CaseHalf Brick
Size / Dimension2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm)
RoHS StatusROHS3 Compliant
MSLNot Applicable
REACH StatusREACH Unaffected

Substitute Part Grouping Explanation

The substitute part VE-JWH-EY-F1 is grouped strictly according to the following allowed parameters: input voltage range, output voltage and current, power rating, isolation voltage, single output, application category, protection features, efficiency, mounting type, package style, regulatory compliance (RoHS3, REACH), and operating temperature range. Mechanical dimensions are accounted for in compatibility grouping.

Parameter Comparison

Parameter VE-JWH-EY VE-JWH-EY-F1
ManufacturerVicor CorporationVicor Corporation
SeriesVE-J00™ (50W)VE-J00™ (50W)
Product StatusObsoleteActive
TypeIsolated ModuleIsolated Module
Number of Outputs11
Voltage - Input (Min)18V18V
Voltage - Input (Max)36V36V
Voltage - Output 152V52V
Current - Output (Max)962mA962mA
Power (Watts)50W50W
Voltage - Isolation3kV3kV
ApplicationsITE (Commercial)ITE (Commercial)
FeaturesOCP, SCPOCP, SCP
Operating Temperature-10°C ~ 100°C-10°C ~ 100°C
Efficiency88%88%
Mounting TypeThrough HoleThrough Hole
Package / CaseHalf BrickHalf Brick
Size / Dimension2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm)2.28" L x 1.86" W x 0.79" H (57.9mm x 47.2mm x 20.1mm)
RoHS StatusROHS3 CompliantROHS3 Compliant
MSLNot ApplicableNot Applicable
REACH StatusREACH UnaffectedREACH Unaffected

Engineering Selection Recommendations

VE-JWH-EY is obsolete. VE-JWH-EY-F1 maintains active product status and shares identical electrical and regulatory parameters, including RoHS3 and REACH compliance. The substitute part differs in size and mechanical configuration but remains within the same half-brick through-hole package standard, supporting direct replacement where mechanical fit is verified with provided dimensions.

Frequently Asked Questions (FAQ)

Q1: What are the critical electrical parameters governing substitution for VE-JWH-EY?
A1: Input voltage range, output voltage and current, power rating, isolation voltage, number of outputs, efficiency, and protection features (OCP, SCP).

Q2: Are the substitute and original modules compatible in commercial ITE applications?
A2: Both parts list ITE (Commercial) applications and identical performance features.

Q3: Does the change in size/dimension impact mounting or thermal aspects?
A3: Size and mechanical dimensions differ; both are half-brick through-hole packages. Compatibility must be verified against system mechanical constraints.

Q4: Are regulatory compliance and certifications maintained in the substitute part?
A4: Both VE-JWH-EY and VE-JWH-EY-F1 are ROHS3 Compliant and REACH Unaffected.

Q5: Is additional derating required due to the substitution?
A5: The substitute part matches all allowed electrical and environmental parameters. Derating criteria are not specified in the provided parameters.

Q6: Is the moisture sensitivity level (MSL) the same for both parts?
A6: Both parts are listed as "Not Applicable" for MSL.

Request Quote (Ships tomorrow)