Equivalent & Substitute Parts for Vicor VE-J00-CY-S DC DC Converter
Part Overview
The Vicor Corporation VE-J00-CY-S is an isolated module DC DC converter designed for ITE (Commercial) applications. This model offers 1 output at 5V, delivering up to 10A with a 10V–20V input range and 3kV isolation. With features including overcurrent protection (OCP) and short-circuit protection (SCP), efficiency of 90%, and ROHS3 compliance, it is suitable for through-hole mounting in half brick packaging. The VE-J00-CY-S has an obsolete product status, necessitating identification of alternative models to maintain product lifecycle, support ongoing manufacturing, and ensure compliance.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VE-J00-CY-S | Vicor Corporation | VE-J00™ (50W) | Obsolete | Isolated Module | 1 | 10V | 20V | 5V | 10A | 50 W | 3 kV | ITE (Commercial) | OCP, SCP | -25°C ~ 100°C | 90% | Through Hole | Half Brick | 2.28" L x 1.80" W x 0.52" H | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute selection for the VE-J00-CY-S is based strictly on matching key electrical and mechanical parameters, which include: input voltage range (10V–20V), output voltage (5V), output current (10A), power rating (50W), voltage isolation (3kV), mounting type (Through Hole), package/case (Half Brick), efficiency (90%), operating temperature (-25°C ~ 100°C), compliance status (ROHS3, REACH), and application suitability (ITE Commercial). Only parts with identical or fully matching values for these parameters are considered as legitimate substitutes.
Parameter Comparison
| Manufacturer Part Number | Product Status | Series | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VE-J00-CY-S | Obsolete | VE-J00™ (50W) | Isolated Module | 1 | 10V | 20V | 5V | 10A | 50 W | 3 kV | ITE (Commercial) | OCP, SCP | -25°C ~ 100°C | 90% | Through Hole | Half Brick | 2.28" L x 1.80" W x 0.52" H | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
| VE-J00-CY-F1 | Active | VE-J00™ (50W) | Isolated Module | 1 | 10V | 20V | 5V | 10A | 50 W | 3 kV | ITE (Commercial) | OCP, SCP | -25°C ~ 100°C | 90% | Through Hole | Half Brick | 2.28" L x 1.86" W x 0.79" H | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
Selection between VE-J00-CY-S and VE-J00-CY-F1 is determined by product status, compliance, and certification provided within the parameters. VE-J00-CY-S is obsolete, while VE-J00-CY-F1 is active. Both are ROHS3 compliant and REACH unaffected, meeting environmental requirements. ECCN and HTSUS codes match, maintaining regulatory consistency. Mechanical package and mounting types are both specified as half brick and through hole. Size and dimensional differences must be considered for mechanical fit.
Frequently Asked Questions (FAQ)
Q: What defines compatibility between VE-J00-CY-S and VE-J00-CY-F1?
A: Compatibility is based on identical input and output parameters, isolation, protection features, mounting style, operating temperature range, efficiency, and compliance status.
Q: Are the package sizes exactly the same between the two models?
A: VE-J00-CY-S has dimensions of 2.28" L x 1.80" W x 0.52" H; VE-J00-CY-F1 is 2.28" L x 1.86" W x 0.79" H. Assess fit within mechanical constraints.
Q: Do both parts support the same environmental and regulatory standards?
A: Both are ROHS3 compliant, REACH unaffected, and have matching ECCN and HTSUS codes.
Q: Is substitution suitable for all ITE (Commercial) applications?
A: Both parts are specified for ITE (Commercial) applications per parameter documentation.
Q: Does mounting type conflict between substitutes?
A: Both VE-J00-CY-S and VE-J00-CY-F1 specify through hole mounting and half brick package/case.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts