Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for VE-BNP-EX-S
Part Overview
Manufacturer part number VE-BNP-EX-S is an isolated module DC-DC converter from Vicor Corporation. It delivers 13.8V output at 5.43A with a power rating of 75W, operating over a 36V to 76V input range. Its main features include 3 kV isolation, multiple protections (OCP, OTP, OVP, SCP), and a full brick package suitable for through-hole mounting. The product is classified as obsolete, necessitating the identification of substitute models to maintain design support, ongoing manufacturing, and field serviceability.
Substiute Parts
Key Parameters
| Parameter | VE-BNP-EX-S |
|---|---|
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 36V |
| Voltage - Input (Max) | 76V |
| Voltage - Output 1 | 13.8V |
| Current - Output (Max) | 5.43A |
| Power (Watts) | 75 W |
| Voltage - Isolation | 3 kV |
| Efficiency | 88% |
| Operating Temperature | -10°C ~ 85°C |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 1.80" W x 0.52" H (116.8mm x 45.7mm x 13.2mm) |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute components are grouped strictly by matching key electrical and mechanical parameters. Parameters selected for determining substitution compatibility include: type, number of outputs, input voltage range, output voltage, output current, power rating, isolation voltage, efficiency, protection features, operating temperature range, mounting type, package/case style, package size/dimensions, RoHS status, REACH status, ECCN, and HTSUS code. Only parts meeting these criteria without deviation are considered substitutes.
Parameter Comparison
| Parameter | VE-BNP-EX-S | VE-BNP-EX-F1 |
|---|---|---|
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VE-200™ (75W) | VE-200™ (75W) |
| Product Status | Obsolete | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 36V | 36V |
| Voltage - Input (Max) | 76V | 76V |
| Voltage - Output 1 | 13.8V | 13.8V |
| Current - Output (Max) | 5.43A | 5.43A |
| Power (Watts) | 75 W | 75 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| Operating Temperature | -10°C ~ 85°C | -10°C ~ 85°C |
| Efficiency | 88% | 88% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.60" L x 1.80" W x 0.52" H (116.8mm x 45.7mm x 13.2mm) | 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
VE-BNP-EX-S is classified as obsolete. VE-BNP-EX-F1 is classified as active. Both are ROHS3 compliant and REACH unaffected. Both share the same ECCN and HTSUS classifications. These statuses, along with identical electrical and protection parameters, permit selection of VE-BNP-EX-F1 as a substitute for cases where compliance, stocking, and regulatory requirements are relevant.
Frequently Asked Questions (FAQ)
Q1: What parameters are critical for substituting VE-BNP-EX-S?
A1: Critical parameters include input voltage range, output voltage and current, power rating, isolation voltage, efficiency, mounting type, package/case style, operating temperature range, and regulatory compliance.
Q2: Are there differences in size or mounting between VE-BNP-EX-S and VE-BNP-EX-F1?
A2: Both use a full brick case and through-hole mounting. Size and dimension differ slightly: VE-BNP-EX-S measures 4.60" L x 1.80" W x 0.52" H, while VE-BNP-EX-F1 is 4.60" L x 1.86" W x 0.79" H.
Q3: Is the substitute part RoHS and REACH compliant?
A3: Both VE-BNP-EX-S and VE-BNP-EX-F1 are ROHS3 compliant and REACH unaffected.
Q4: Is the electrical performance matched between these parts?
A4: The electrical specifications for input voltage, output voltage, current, power, isolation voltage, efficiency, and operating temperature are identical.
Q5: Can VE-BNP-EX-F1 be used in applications requiring the same licensing codes (ECCN and HTSUS)?
A5: Both parts have identical ECCN (EAR99) and HTSUS (8504.40.9580) classifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts