Equivalent & Substitute Parts for VDSD1-S12-DI12-DIP

Part Overview

VDSD1-S12-DI12-DIP is an isolated module DC-DC converter manufactured by CUI Inc. It provides dual outputs of +12V and -12V at 42mA each, with a total output power of 1W. The converter operates within an input voltage range of 10.8V to 13.2V and features 1 kV isolation. With an operating temperature range of -40°C to 85°C and compliance for ITE (Commercial) applications, it is suitable for various industrial and commercial uses. The product status is obsolete, necessitating the identification of substitute components with matching electrical, mechanical, and regulatory parameters.

Substiute Parts

VDSD1-S12-DI12-DIP
CUI Inc.In Stock: 784VDSD1-S12-DI12-DIP Datasheet
VDSD1-S12-DI12-DIP
Current Part
IA1212D
XP PowerIn Stock: 1237IA1212D Datasheet
IA1212D
Similar

Key Parameters

ParameterVDSD1-S12-DI12-DIP
ManufacturerCUI Inc.
Product StatusObsolete
TypeIsolated Module
Number of Outputs2
Voltage - Input (Min)10.8V
Voltage - Input (Max)13.2V
Voltage - Output 112V
Voltage - Output 2-12V
Current - Output (Max)42mA, 42mA
Power (Watts)1 W
Voltage - Isolation1 kV
ApplicationsITE (Commercial)
FeaturesSCP
Operating Temperature-40°C ~ 85°C
Efficiency79%
Mounting TypeThrough Hole
Package / Case14-DIP Module, 7 Leads
Size / Dimension0.80" L x 0.39" W x 0.28" H (20.4mm x 10.0mm x 7.0mm)
Approval AgencycURus
Moisture Sensitivity Level (MSL)Not Applicable
SeriesVDSD1-DIP (1W)
Compliance/RegulationOBSOLETE

Substitute Part Grouping Explanation

Substitute parts for DC-DC converters in this category must match on the following key parameters: input voltage range, output voltages, output current, output power, isolation voltage, number of outputs, mounting type, and operating temperature range. Approval agency and compliance standards are also considered when available. For mechanical substitution, package/case type and dimensions must be reviewed based on available information. Only those parts that meet or exceed all critical parameters are considered as equivalent substitutes.

Parameter Comparison

Parameter VDSD1-S12-DI12-DIP
(CUI Inc.)
IA1212D
(XP Power)
TypeIsolated ModuleIsolated Module
Number of Outputs22
Voltage - Input (Min)10.8V10.8V
Voltage - Input (Max)13.2V13.2V
Voltage - Output 112V12V
Voltage - Output 2-12V-12V
Current - Output (Max)42mA, 42mA42mA
Power (Watts)1 W1 W
Voltage - Isolation1 kV1 kV
ApplicationsITE (Commercial)ITE (Commercial)
Operating Temperature-40°C ~ 85°C-40°C ~ 85°C
Efficiency79%78%
Mounting TypeThrough HoleThrough Hole
Package / Case14-DIP Module, 7 Leads6-DIP Module
Size / Dimension0.80" L x 0.39" W x 0.28" H (20.4mm x 10.0mm x 7.0mm)0.80" L x 0.40" W x 0.25" H (20.3mm x 10.2mm x 6.4mm)
Approval AgencycURus-
Moisture Sensitivity Level (MSL)Not Applicable1 (Unlimited)
SeriesVDSD1-DIP (1W)IA (1W)
Product StatusObsoleteActive

Engineering Selection Recommendations

The VDSD1-S12-DI12-DIP is listed as obsolete, which commonly necessitates the selection of an alternative component to maintain product availability and design support. The substitute part IA1212D from XP Power is currently active and matches all key electrical parameters including input voltage range, output voltages, output current, output power, isolation, application suitability, mounting type, and operating temperature range. Approval agency documentation and moisture sensitivity differ; cURus marking is present for the original part, while the substitute lists no approval agency. Series and packaging types vary. RoHS compliance is specified only for the substitute part.

Frequently Asked Questions (FAQ)

Q: What are the most important parameters to compare when selecting a substitute for VDSD1-S12-DI12-DIP?
A: The essential parameters include input voltage range, output voltage(s), output current, power rating, isolation voltage, number of outputs, mounting type, and operating temperature range.

Q: Can IA1212D be used in the same PCB footprint as VDSD1-S12-DI12-DIP?
A: Both modules are through-hole types with similar size and dimensions. Package lead counts and form factors differ (14-DIP vs. 6-DIP); mechanical compatibility must be verified using manufacturer drawings.

Q: Are there differences in regulatory approvals between the original and substitute parts?
A: VDSD1-S12-DI12-DIP lists cURus approval, while IA1212D does not specify an approval agency in the provided data.

Q: Is the efficiency similar between the VDSD1-S12-DI12-DIP and IA1212D?
A: Efficiency values are close: 79% for VDSD1-S12-DI12-DIP and 78% for IA1212D.

Q: What are the differences in moisture sensitivity between the two parts?
A: VDSD1-S12-DI12-DIP lists "Not Applicable" for MSL, while IA1212D is specified as MSL 1 (Unlimited).

Q: Do both parts support commercial ITE applications?
A: Yes, both parts are specified for ITE (Commercial) applications according to provided information.

Q: Which part is available as an active product?
A: VDSD1-S12-DI12-DIP is obsolete and IA1212D is active.

Request Quote (Ships tomorrow)