Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for VCP05US05
Part Overview
The VCP05US05, manufactured by XP Power, is an open frame AC/DC converter providing a single 5V output at 1A (5W). It is designed for ITE (Commercial) applications with universal input capability (90~264 VAC), certified by cUL, IEC, and EN standards, and meets RoHS3 compliance. The product is classified as obsolete, which necessitates identifying suitable alternatives with comparable electrical, mechanical, and regulatory parameters to ensure continued system functionality and compliance.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Series | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Features | Operating Temperature | Mounting Type | Package / Case | Approval Agency | Standard Number | Line Regulation | Load Regulation | RoHS Status | MSL |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VCP05US05 | VCP (5W) | Open Frame | 1 | 90 ~ 264 VAC | 5V | 1A | 5 W | ITE (Commercial) | Universal Input | 0°C ~ 70°C (With Derating) | Through Hole | 5-DIP Module | cUL, IEC, EN | 62368-1 | ±0.5% | 2% | ROHS3 Compliant | 1 (Unlimited) |
| VCE05US05 | VCE05 (5W) | Enclosed | 1 | 85 ~ 264 VAC | 5V | 1A | 5 W | ITE (Commercial) | Universal Input | -25°C ~ 70°C (With Derating) | Through Hole | 4-DIP Module | CB | 62368-1 | ±1% | ±3% | ROHS3 Compliant | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitute parts for the VCP05US05 have been identified by matching the following parameters: number of outputs (1), output voltage (5V), maximum output current (1A), power rating (5W), input voltage range (including 90~264 VAC), application category (ITE), mounting type (Through Hole), RoHS3 compliance, operating temperature range, and regulatory approvals. Differences in mechanical configuration (open frame versus enclosed, DIP module count) and approval agencies are explicitly noted in the parameter comparison.
Parameter Comparison
| Manufacturer Part Number | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Features | Operating Temperature | Mounting Type | RoHS Status | MSL | Standard Number |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VCP05US05 | Open Frame | 1 | 90 ~ 264 VAC | 5V | 1A | 5 W | ITE (Commercial) | Universal Input | 0°C ~ 70°C (With Derating) | Through Hole | ROHS3 Compliant | 1 (Unlimited) | 62368-1 |
| VCE05US05 | Enclosed | 1 | 85 ~ 264 VAC | 5V | 1A | 5 W | ITE (Commercial) | Universal Input | -25°C ~ 70°C (With Derating) | Through Hole | ROHS3 Compliant | 1 (Unlimited) | 62368-1 |
Engineering Selection Recommendations
VCP05US05 is classified as obsolete, while VCE05US05 is active. Both parts are RoHS3 compliant, support the same output and input specifications, and are suitable for ITE (Commercial) applications. The key difference lies in mechanical format (open frame vs enclosed), package size, DIP module configuration, and safety approvals (cUL/IEC/EN for VCP05US05, CB for VCE05US05). Standard compliance (62368-1) is common to both.
Frequently Asked Questions (FAQ)
Q1: What are the main criteria for substituting VCP05US05?
A1: Key substitution criteria include matching output voltage (5V), output current (1A), power rating (5W), universal AC input range, single output configuration, ITE (Commercial) application, mounting type (Through Hole), regulatory standard (62368-1), and RoHS3 compliance.
Q2: How do package differences affect substitution?
A2: VCP05US05 uses a 5-DIP open frame module; VCE05US05 uses a 4-DIP enclosed module. The difference in DIP module configuration and enclosure may require evaluating board layout compatibility.
Q3: Are there differences in regulatory or safety certifications?
A3: VCP05US05 holds cUL, IEC, and EN approvals. VCE05US05 carries CB approval. Both comply with standard 62368-1.
Q4: Does operating temperature range restrict substitution?
A4: Both models operate up to 70°C. VCE05US05 supports a wider low-end range starting from -25°C, while VCP05US05 starts at 0°C.
Q5: Are both products compliant with RoHS3 and moisture sensitivity standards?
A5: Both parts are RoHS3 compliant and rated MSL 1 (unlimited).
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts