Request Quote
(Ships tomorrow)
VCAS120642L800TP Equivalent & Substitute Parts
Part Overview
The VCAS120642L800TP is a 51 V, 180 A Transient Voltage Suppressor (TVS) varistor manufactured by KYOCERA AVX under the FLEXITERM® series. This surface mount component is designed for transient voltage protection in automotive and industrial applications. The part is currently Active in product status with full AEC-Q200 automotive qualification and ROHS3 compliance. Substitute parts are identified to support procurement flexibility, inventory management, and supply chain continuity while maintaining identical electrical and mechanical performance specifications.
Substiute Parts
Key Parameters
| Parameter | Value | Unit |
|---|---|---|
| Varistor Voltage (Typical) | 51 | V |
| Varistor Voltage Range (Min-Max) | 45.9 - 56.1 | V |
| Current - Surge | 180 | A |
| Energy Absorption | 0.8 | J |
| Maximum AC Voltage | 32 | V |
| Maximum DC Voltage | 42 | V |
| Capacitance @ 1 kHz | 600 | pF |
| Operating Temperature Range | -55 to 125 | °C |
| Package / Case | 1206 (3216 Metric) | - |
| Mounting Type | Surface Mount, MLCV | - |
| Number of Circuits | 1 | - |
Substitute Part Grouping Explanation
Substitution of the VCAS120642L800TP is determined by strict equivalence across all critical electrical and mechanical parameters. The substitute part VC120642L800DP is classified as a parametric equivalent based on the following criteria:
Substitution-Determining Parameters:
- Varistor voltage rating: 51 V (typical), with identical minimum and maximum tolerances (45.9 V - 56.1 V)
- Surge current capacity: 180 A
- Energy absorption: 0.8 J
- Maximum AC and DC voltage ratings: 32 V AC / 42 V DC
- Capacitance specification: 600 pF @ 1 kHz
- Operating temperature range: -55°C to 125°C
- Package designation: 1206 (3216 Metric) surface mount
- Mounting technology: MLCV surface mount
- Single circuit configuration
Both parts are manufactured by KYOCERA AVX, maintain Active product status, carry AEC-Q200 automotive qualification, and comply with ROHS3 and REACH requirements. The substitute part is functionally and mechanically interchangeable for all applications requiring the specified electrical performance envelope.
Parameter Comparison
| Parameter | VCAS120642L800TP | VC120642L800DP | Match |
|---|---|---|---|
| Manufacturer | KYOCERA AVX | KYOCERA AVX | ✓ |
| Category | Transient Voltage Suppressors (TVS) | Transient Voltage Suppressors (TVS) | ✓ |
| Varistor Voltage (Typ) | 51 V | 51 V | ✓ |
| Varistor Voltage (Min) | 45.9 V | 45.9 V | ✓ |
| Varistor Voltage (Max) | 56.1 V | 56.1 V | ✓ |
| Current - Surge | 180 A | 180 A | ✓ |
| Energy | 0.8 J | 0.8 J | ✓ |
| Maximum AC Volts | 32 V | 32 V | ✓ |
| Maximum DC Volts | 42 V | 42 V | ✓ |
| Number of Circuits | 1 | 1 | ✓ |
| Capacitance @ 1 kHz | 600 pF | 600 pF | ✓ |
| Operating Temperature | -55°C ~ 125°C | -55°C ~ 125°C | ✓ |
| Mounting Type | Surface Mount, MLCV | Surface Mount, MLCV | ✓ |
| Package / Case | 1206 (3216 Metric) | 1206 (3216 Metric) | ✓ |
| Product Status | Active | Active | ✓ |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ✓ |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | ✓ |
| REACH Status | REACH Unaffected | REACH Unaffected | ✓ |
| AEC-Q200 Qualification | Yes | Yes | ✓ |
Engineering Selection Recommendations
Both VCAS120642L800TP and VC120642L800DP are qualified for direct substitution in applications requiring 51 V varistor protection with 180 A surge current capacity. Selection between these parts should be based on the following engineering considerations:
Compliance and Qualification: Both parts maintain identical AEC-Q200 automotive qualification status, ROHS3 compliance, and REACH unaffected designation. Either part is suitable for automotive and industrial applications subject to these regulatory frameworks.
Product Availability: VCAS120642L800TP: 1170 Pcs in stock VC120642L800DP: 765 Pcs in stock
Selection may be influenced by inventory availability and procurement lead time requirements.
Packaging and Handling: Both parts are supplied in Tape & Reel (TR) packaging with MSL Level 1 (Unlimited) moisture sensitivity rating, indicating no special moisture control requirements during storage or handling.
Thermal and Electrical Performance: Identical operating temperature range (-55°C to 125°C) and electrical specifications ensure equivalent performance in all circuit applications. No derating or performance adjustment is required when substituting between these parts.
Frequently Asked Questions (FAQ)
Q: Can VC120642L800DP be used as a direct replacement for VCAS120642L800TP?
A: Yes. Both parts are parametric equivalents with identical electrical specifications, including 51 V varistor voltage, 180 A surge current, 0.8 J energy absorption, and operating temperature range. They share the same 1206 (3216 Metric) surface mount package and MLCV mounting technology. No circuit modifications are required.
Q: Are there any differences in automotive qualification between these parts?
A: No. Both VCAS120642L800TP and VC120642L800DP carry AEC-Q200 qualification and are suitable for automotive applications. Compliance status is identical.
Q: What is the significance of the part number suffix (TP vs. DP)?
A: The suffix indicates packaging or distribution channel designation within KYOCERA AVX's product line. Both suffixes represent the same electrical component with identical performance specifications.
Q: Do these parts require different PCB footprints?
A: No. Both parts use the 1206 (3216 Metric) package with identical surface mount MLCV mounting technology. PCB footprints and assembly processes are identical.
Q: Are there any moisture sensitivity or storage requirement differences?
A: No. Both parts carry MSL Level 1 (Unlimited) rating, indicating no special moisture control measures are required during storage, handling, or assembly.
Q: Can these parts be mixed in the same production batch?
A: Yes. Since both parts are parametric equivalents with identical electrical and mechanical specifications, they can be used interchangeably in the same design and production environment without functional or reliability impact.
Q: What is the basis for substitution eligibility?
A: Substitution is based on strict equivalence of all critical parameters: varistor voltage rating (45.9 V - 56.1 V), surge current (180 A), energy absorption (0.8 J), maximum voltage ratings (32 V AC / 42 V DC), capacitance (600 pF @ 1 kHz), operating temperature range (-55°C to 125°C), package type (1206 / 3216 Metric), and mounting technology (surface mount MLCV). Both parts are manufactured by the same supplier and maintain identical compliance certifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts