Request Quote
(Ships tomorrow)
VBO20-08NO2 Equivalent & Substitute Parts
Part Overview
The VBO20-08NO2 is a single-phase bridge rectifier manufactured by IXYS, rated for 800 V peak reverse voltage and 31 A average rectified current. This component is classified as obsolete, making identification of suitable substitute parts essential for ongoing system maintenance and new design implementations. The part features a 4-Square FO-A package with QC terminals and operates across a temperature range of -40°C to 150°C.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | VBO20-08NO2 |
| Manufacturer | IXYS |
| Category | Diodes |
| Diode Type | Single Phase |
| Technology | Standard |
| Voltage - Peak Reverse (Max) | 800 V |
| Current - Average Rectified (Io) | 31 A |
| Voltage - Forward (Vf) (Max) @ If | 1.8 V @ 55 A |
| Current - Reverse Leakage @ Vr | 300 µA @ 800 V |
| Operating Temperature Range | -40°C ~ 150°C (TJ) |
| Mounting Type | QC Terminal |
| Package / Case | 4-Square, FO-A |
| Product Status | Obsolete |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the VBO20-08NO2 is determined by the following critical electrical and mechanical parameters:
Electrical Compatibility Criteria:
- Voltage - Peak Reverse (Max): Must equal or exceed 800 V
- Current - Average Rectified (Io): Must equal or exceed 31 A
- Diode Type: Must be Single Phase
- Technology: Must be Standard
Mechanical Compatibility Criteria:
- Mounting Type: Must be QC Terminal
- Package / Case: Must be 4-Square, FO-A
Compliance & Environmental Criteria:
- RoHS Status: ROHS3 Compliant
- Operating Temperature Range: Must support -40°C ~ 150°C (TJ)
The VBO25-12NO2 meets all substitution criteria, offering higher voltage and current ratings within the same package form factor and mounting configuration.
Parameter Comparison
| Parameter | VBO20-08NO2 (Main Part) | VBO25-12NO2 (Substitute) |
|---|---|---|
| Manufacturer | IXYS | IXYS |
| Diode Type | Single Phase | Single Phase |
| Technology | Standard | Standard |
| Voltage - Peak Reverse (Max) | 800 V | 1.2 kV |
| Current - Average Rectified (Io) | 31 A | 38 A |
| Voltage - Forward (Vf) (Max) @ If | 1.8 V @ 55 A | 1.36 V @ 55 A |
| Current - Reverse Leakage @ Vr | 300 µA @ 800 V | 300 µA @ 1200 V |
| Operating Temperature Range | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) |
| Mounting Type | QC Terminal | QC Terminal |
| Package / Case | 4-Square, FO-A | 4-Square, FO-A |
| Product Status | Obsolete | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
The VBO25-12NO2 is the direct substitute for the obsolete VBO20-08NO2. Both components share identical mechanical interfaces (4-Square FO-A package with QC terminals), identical operating temperature ranges, and equivalent compliance certifications (ROHS3 Compliant, MSL 1).
The VBO25-12NO2 provides superior electrical performance with 1.2 kV peak reverse voltage capability versus 800 V, and 38 A average rectified current versus 31 A. The forward voltage drop is lower at 1.36 V compared to 1.8 V at 55 A, resulting in improved thermal efficiency.
Both parts maintain identical reverse leakage current specifications at their respective voltage ratings and support the full -40°C to 150°C operating temperature range. The active product status of the VBO25-12NO2 ensures long-term availability and supply chain continuity.
Frequently Asked Questions (FAQ)
Q: Can the VBO25-12NO2 directly replace the VBO20-08NO2 in existing designs?
A: Yes. Both components use identical QC Terminal mounting and 4-Square FO-A package configurations. Electrical ratings of the VBO25-12NO2 exceed those of the VBO20-08NO2, providing backward compatibility for applications originally designed for the obsolete part.
Q: What are the key differences between these two bridge rectifiers?
A: The VBO25-12NO2 offers higher voltage (1.2 kV vs. 800 V) and current (38 A vs. 31 A) ratings. Forward voltage drop is lower (1.36 V vs. 1.8 V at 55 A). The VBO25-12NO2 is active in production, while the VBO20-08NO2 is obsolete.
Q: Are there any compliance or environmental differences?
A: No. Both parts are ROHS3 Compliant, carry MSL 1 (Unlimited) moisture sensitivity ratings, and support identical operating temperature ranges of -40°C to 150°C (TJ).
Q: Does the package form factor remain the same?
A: Yes. Both the VBO20-08NO2 and VBO25-12NO2 use the 4-Square FO-A package with QC Terminal mounting, ensuring mechanical compatibility without PCB redesign.
Q: Why is forward voltage lower in the VBO25-12NO2?
A: The VBO25-12NO2 exhibits lower forward voltage (1.36 V vs. 1.8 V at 55 A) due to improved semiconductor technology in the active product line, resulting in reduced power dissipation during operation.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts