Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for Vicor V048F080T030
Part Overview
The Vicor V048F080T030 is a Voltage Transformation Module DC-DC Converter, designed for ITE (Commercial) applications with a single output of 8V at 30A, supporting input voltage from 26V to 55V. The product status is “Obsolete,” necessitating identification of direct substitute models for continued design support, maintenance, and manufacturing requirements. Substitution is required due to end-of-life status and to ensure uninterrupted supply with functionally equivalent components.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Type | Series | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | ECCN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| V048F080T030 | Voltage Transformation Module | VI Chip® VTM® | 1 | 26V | 55V | 8V | 30A | 240 W | 2.25 kV | ITE (Commercial) | Remote On/Off | -40°C ~ 125°C | 95.8% | Surface Mount | Module | 1.28" L x 0.87" W x 0.26" H | ROHS3 Compliant | REACH Unaffected | EAR99 |
Substitute Part Grouping Explanation
Substitute eligibility is strictly defined by matching the following key parameters: input voltage range (26V–55V), output voltage and current (8V, 30A), single output configuration, power rating (240 W), isolation voltage (2.25 kV), mounting type (surface mount), package dimensions, and compliance statuses (RoHS, REACH, ECCN). Additional relevant features such as remote on/off and operational temperature must align. Substitute parts are selected only if all these parameters match, ensuring form, fit, and function compatibility.
Parameter Comparison
| Manufacturer Part Number | Product Status | Type | Series | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | ECCN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| V048F080T030 | Obsolete | Voltage Transformation Module | VI Chip® VTM® | 1 | 26V | 55V | 8V | 30A | 240 W | 2.25 kV | ITE (Commercial) | Remote On/Off | -40°C ~ 125°C | 95.8% | Surface Mount | Module | 1.28" L x 0.87" W x 0.26" H | ROHS3 Compliant | REACH Unaffected | EAR99 |
| VTM48EF080T030A00 | Active | Voltage Transformation Module | VI Chip® VTM® | 1 | 26V | 55V | 8V | 30A | 240 W | 2.25 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP | -40°C ~ 125°C | 95% | Surface Mount | Module | 1.28" L x 0.87" W x 0.26" H | ROHS3 Compliant | REACH Unaffected | EAR99 |
Engineering Selection Recommendations
Based on product status, V048F080T030 is obsolete and VTM48EF080T030A00 is active. Both parts are ROHS3 compliant and REACH unaffected, with the same ECCN classification. Substitute selection is supported by their identical electrical and mechanical parameters, compliance certifications, and compatible package format.
Frequently Asked Questions (FAQ)
Q1: What are the strict requirements for substituting Vicor V048F080T030 with another DC-DC converter module?
A1: Substitution requires matching input voltage range, output voltage and current, number of outputs, power rating, isolation voltage, mounting type, package dimensions, and compliance statuses.
Q2: Is VTM48EF080T030A00 fully compatible with the footprint and mechanical form factor of V048F080T030?
A2: Both parts have identical surface mount module format and specified size/dimensions.
Q3: Do substitute parts offer identical electrical operating ranges and protection functions?
A3: Electrical operating ranges are equivalent. VTM48EF080T030A00 includes additional protection features as listed.
Q4: Are compliance and inventory levels comparable for immediate replacement?
A4: Both are ROHS3 compliant, REACH unaffected, and available in new original stock quantities.
Q5: Is there any change in operating temperature or application compatibility between these models?
A5: Operating temperature and applications (ITE Commercial) are the same for both parts.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts