The Murata Power Solutions Inc. UWR-5/1600-D5A-C is a DC-DC isolated module converter with a single 5V output rated at 1.6A and total power output of 8W. This model is classified as obsolete, necessitating identification and utilization of alternative models to meet ongoing or new design and maintenance requirements.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| UWR-5/1600-D5A-C | Murata Power Solutions Inc. | Obsolete | Isolated Module | 1 | 4.7V | 7.25V | 5V | 1.6A | 8W | 1.5 kV | ITE (Commercial) | -40°C ~ 70°C | 76% | Through Hole | 5-DIP Module | 2.00" L x 1.00" W x 0.38" H | ROHS3 Compliant | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute parts are grouped strictly on the basis of matching or exceeding the key electrical and mechanical parameters as provided, including output voltage, maximum output current, input voltage range, isolation voltage, mounting type, and regulatory compliance. Only models meeting these published criteria are listed as substitutes.
Key parameters for substitution:
- Output Voltage (5V)
- Output Current (≥1.6A)
- Input Voltage Range (minimum 4.7V, maximum at least 7.25V)
- Voltage Isolation (1.5 kV)
- Power Rating (≥8W)
- Mounting Type (Through Hole)
- Regulatory Compliance (RoHS, REACH)
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| UWR-5/1600-D5A-C | Murata Power Solutions Inc. | Obsolete | Isolated Module | 1 | 4.7V | 7.25V | 5V | 1.6A | 8W | 1.5 kV | ITE (Commercial) | -40°C ~ 70°C | 76% | Through Hole | 5-DIP Module | 2.00" L x 1.00" W x 0.38" H | ROHS3 Compliant | REACH Unaffected | EAR99 | 8504.40.9580 |
| EC4BU-05S05 | Cincon Electronics Co. LTD | Active | Isolated Module | 1 | 4.7V | 9V | 5V | 2A | 10W | 1.5 kV | ITE (Commercial) | -40°C ~ 105°C (With Derating) | 87% | Through Hole | 6-DIP Module | 2.00" L x 1.00" W x 0.40" H | ROHS3 Compliant | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
The Murata Power Solutions Inc. UWR-5/1600-D5A-C is currently obsolete. EC4BU-05S05 from Cincon Electronics Co. LTD is listed as active and provides compatible electrical ratings, mechanical dimensions, and mounting type. Both parts are ROHS3 compliant and REACH unaffected, sharing the same ECCN and HTSUS classifications.
Frequently Asked Questions (FAQ)
Q: What parameters determine if EC4BU-05S05 can directly substitute for UWR-5/1600-D5A-C?
A: EC4BU-05S05 matches the output voltage (5V), supports higher output current (2A vs 1.6A), covers the required input voltage range, provides the same isolation voltage (1.5 kV), and uses through-hole mounting with similar dimensions.
Q: Are there mechanical differences in package and size between the primary and substitute parts?
A: The EC4BU-05S05 is specified as a 6-DIP module, while the UWR-5/1600-D5A-C uses a 5-DIP module; both share comparable dimensions (2.00" L x 1.00" W, with height difference <0.02"), and both are through-hole.
Q: Is regulatory compliance maintained when substituting EC4BU-05S05 for UWR-5/1600-D5A-C?
A: Both products are ROHS3 compliant and REACH unaffected. They share identical ECCN (EAR99) and HTSUS codes.
Q: Does the substitute part’s operating temperature affect compatibility?
A: The substitute part EC4BU-05S05 covers a broader operating temperature range (-40°C ~ 105°C with derating) compared to the primary part’s range of -40°C ~ 70°C.
Q: Can the substitute be used in the same ITE (Commercial) applications?
A: Both parts specify suitability for ITE (Commercial) applications.
Q: What should be considered concerning inventory and availability status?
A: The primary part is obsolete, while the substitute is listed as active and available, which is necessary for ongoing procurement.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts