Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for UWE-15/5-Q48N-C
Part Overview
Murata Power Solutions Inc. model UWE-15/5-Q48N-C is an isolated DC DC converter in the 1/8 Brick format, delivering a regulated 15V output at up to 5A with an input voltage range of 18V to 75V. This part is categorized as an Isolated Module and is suitable for ITE (Commercial) applications. It offers multiple protection features and boasts high efficiency with remote control capability. The product is currently at "Last Time Buy" status, making identification of substitute models imperative for long-term design continuity and supply assurance.
Substiute Parts
Key Parameters
| Parameter | Main Part Value |
|---|---|
| Manufacturer Part Number | UWE-15/5-Q48N-C |
| Manufacturer | Murata Power Solutions Inc. |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Input Voltage Range | 18V - 75V |
| Output Voltage | 15V |
| Max Output Current | 5A |
| Output Power | 75 W |
| Isolation Voltage | 2.25 kV |
| Efficiency | 90.5% |
| Operating Temperature | -40°C ~ 85°C |
| Mounting Type | Through Hole |
| Package / Case | 8-DIP Module, 1/8 Brick |
| Control Features | Enable, Active Low |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
Substitute Part Grouping Explanation
Substitute parts for DC DC converters in the 1/8 Brick module category must match critical electrical and mechanical parameters. The substitution is based strictly on the following: manufacturer, series, type, input and output voltage range, output current and power ratings, isolation voltage, efficiency, operating temperature, mounting method, package format, control features, and regulatory compliance (RoHS, MSL, REACH, ECCN). Only models meeting all these specified parameters are issued as valid equivalents.
Parameter Comparison
| Parameter | Main Part (UWE-15/5-Q48N-C) | Substitute Part (UWE-15/5-Q48NB-C) |
|---|---|---|
| Manufacturer Part Number | UWE-15/5-Q48N-C | UWE-15/5-Q48NB-C |
| Manufacturer | Murata Power Solutions Inc. | Murata Power Solutions Inc. |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Input Voltage Range | 18V - 75V | 18V - 75V |
| Output Voltage | 15V | 15V |
| Max Output Current | 5A | 5A |
| Output Power | 75 W | 75 W |
| Isolation Voltage | 2.25 kV | 2.25 kV |
| Efficiency | 90.5% | 90.5% |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 8-DIP Module, 1/8 Brick | 8-DIP Module, 1/8 Brick |
| Control Features | Enable, Active Low | Enable, Active Low |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
Engineering Selection Recommendations
When selecting DC DC converters such as UWE-15/5-Q48N-C and its substitute UWE-15/5-Q48NB-C, prioritize parameters including compliance (RoHS, REACH, ECCN), product status, and packaging format. With UWE-15/5-Q48N-C classified as "Last Time Buy," choosing substitutes that maintain active product status and adhere to identical compliance and certification levels ensures uninterrupted design support and inventory alignment.
Frequently Asked Questions (FAQ)
Q: What are the essential criteria for substituting a DC DC converter in the 1/8 Brick module category?
A: Substitution requires identical values for electrical ratings (input/output voltage, output current, power), isolation voltage, efficiency, operating temperature range, mounting type, package format, and compliance certifications.
Q: Is package compatibility mandatory for direct substitution?
A: Yes, both electrical and mechanical dimensions including mounting type and 1/8 Brick 8-DIP Module case must match exactly for interchangeability.
Q: Do substitute parts require identical control features and protection mechanisms?
A: Yes, features such as Enable, Active Low control, and protection (OCP, OTP, OVP, SCP, UVLO) must be identical to assure functional equivalence.
Q: Can substitutes differ in compliance certifications?
A: No; RoHS, REACH, and ECCN status must be identical for regulatory alignment.
Q: What is the impact of product status on substitute selection?
A: Selection should favor substitutes with "Active" product status over "Last Time Buy" to secure future availability and design longevity.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts