Nichicon UPS1A331MPD1TA Equivalent & Substitute Parts

Part Overview

The Nichicon UPS1A331MPD1TA is a 330 µF, 10 V aluminum electrolytic capacitor in radial configuration with a 2000-hour lifetime rating at 105°C. This component is classified as "Not For New Designs," indicating it has reached end-of-life status. For new applications or ongoing production requiring equivalent functionality, substitute parts with active product status or enhanced specifications are available.

Substiute Parts

UPS1A331MPD1TA
NichiconIn Stock: 877UPS1A331MPD1TA Datasheet
UPS1A331MPD1TA
Current Part
UKA1A331MPD1TD
NichiconIn Stock: 2261UKA1A331MPD1TD Datasheet
UKA1A331MPD1TD
Upgrade
UPA1C331MPD1TA
NichiconIn Stock: 759UPA1C331MPD1TA Datasheet
UPA1C331MPD1TA
Upgrade
UPA1E331MPD1TA
NichiconIn Stock: 1128UPA1E331MPD1TA Datasheet
UPA1E331MPD1TA
Upgrade
UPS1A331MPD1TD
NichiconIn Stock: 1733UPS1A331MPD1TD Datasheet
UPS1A331MPD1TD
Parametric Equivalent

Key Parameters

Parameter Value
Capacitance 330 µF
Voltage Rating 10 V
Tolerance ±20%
Lifetime @ Temperature 2000 Hrs @ 105°C
Operating Temperature Range -55°C ~ 105°C
Polarization Polar
Package Type Radial, Can
Lead Spacing 0.138" (4.60 mm)
Physical Diameter 0.315" (8.00 mm)
Height (Seated Max) 0.512" (13.00 mm)
Mounting Type Through Hole
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution of the UPS1A331MPD1TA is determined by the following critical parameters:

Mandatory Matching Parameters:

  • Capacitance: 330 µF (exact match required)
  • Tolerance: ±20% (exact match required)
  • Polarization: Polar (exact match required)
  • Package Type: Radial, Can (exact match required)
  • Lead Spacing: 0.138" (4.60 mm) (exact match required)
  • Physical Diameter: 0.315" (8.00 mm) (exact match required)
  • Height: 0.512" (13.00 mm) (exact match required)
  • Mounting Type: Through Hole (exact match required)

Allowable Variation Parameters:

  • Voltage Rating: May be equal or higher than 10 V
  • Lifetime @ Temperature: May be equal or higher than 2000 Hrs @ 105°C
  • ESR and Ripple Current: May vary within acceptable operating ranges
  • Product Status: Active status preferred over "Not For New Designs"

Substitute parts are grouped into two categories: Upgrade parts offering enhanced specifications (higher voltage or longer lifetime), and Parametric Equivalent parts maintaining identical electrical specifications with different packaging variants.

Parameter Comparison

Part Number Manufacturer Series Capacitance Voltage Tolerance Lifetime @ 105°C Product Status Inventory
UPS1A331MPD1TA Nichicon UPS 330 µF 10 V ±20% 2000 Hrs Not For New Designs 846 Pcs
UKA1A331MPD1TD Nichicon UKA 330 µF 10 V ±20% 2000 Hrs Not For New Designs 2240 Pcs
UPA1C331MPD1TA Nichicon UPA 330 µF 16 V ±20% 3000 Hrs Active 738 Pcs
UPA1E331MPD1TA Nichicon UPA 330 µF 25 V ±20% 3000 Hrs Active 1044 Pcs
UPS1A331MPD1TD Nichicon UPS 330 µF 10 V ±20% 2000 Hrs Not For New Designs 1682 Pcs

Engineering Selection Recommendations

For New Designs: Select UPA1C331MPD1TA or UPA1E331MPD1TA. Both parts carry Active product status and offer extended lifetime ratings (3000 Hrs @ 105°C versus 2000 Hrs). The UPA series provides superior reliability for long-term applications. UPA1C331MPD1TA (16 V) is suitable for circuits with 10 V nominal operation, providing voltage margin. UPA1E331MPD1TA (25 V) offers additional voltage headroom for applications with transient overvoltage conditions.

For Existing Designs (Maintenance/Repair): UPS1A331MPD1TD provides parametric equivalence to the original UPS1A331MPD1TA with identical electrical specifications. This part maintains the same 10 V rating and 2000-hour lifetime, ensuring drop-in compatibility. Inventory availability (1682 Pcs) supports ongoing production requirements.

For Cost-Optimized Alternatives: UKA1A331MPD1TD maintains the original 10 V specification and 2000-hour lifetime while offering higher inventory availability (2240 Pcs). This part is suitable for applications where voltage and lifetime specifications are non-negotiable.

Compliance Considerations: All substitute parts maintain ROHS3 compliance. UPA1C331MPD1TA and UPA1E331MPD1TA carry REACH Affected status, while UPS1A331MPD1TA, UKA1A331MPD1TD, and UPS1A331MPD1TD maintain REACH Unaffected status. Verify compliance requirements for your specific application and regulatory jurisdiction.

Frequently Asked Questions (FAQ)

Q: Can I use a higher voltage-rated capacitor as a substitute? A: Yes. A 16 V or 25 V rated capacitor can replace a 10 V capacitor in the same physical package, provided all other parameters (capacitance, tolerance, lead spacing, diameter, height) remain identical. Higher voltage ratings provide additional safety margin against transient overvoltage.

Q: What is the difference between UPS1A331MPD1TA and UPS1A331MPD1TD? A: Both parts are parametrically identical with matching capacitance (330 µF), voltage (10 V), tolerance (±20%), and lifetime (2000 Hrs @ 105°C). The difference lies in packaging variant designation (TA versus TD). Both are suitable for through-hole mounting with identical lead spacing and physical dimensions.

Q: Why should I choose UPA series over UPS series? A: UPA series parts carry Active product status and offer extended lifetime (3000 Hrs @ 105°C) compared to UPS series (2000 Hrs @ 105°C). For new designs, Active status ensures long-term availability and manufacturing support. Extended lifetime improves reliability in demanding applications.

Q: Are all substitute parts pin-compatible? A: Yes. All listed substitute parts maintain identical lead spacing (0.138" / 4.60 mm), physical diameter (0.315" / 8.00 mm), and height (0.512" / 13.00 mm). All are radial, through-hole mounted components with polar configuration. Direct PCB mounting compatibility is assured.

Q: What does "Not For New Designs" mean? A: This designation indicates the part has reached end-of-life status and is no longer recommended for new product development. Existing inventory may remain available for maintenance and repair of legacy systems. For new applications, select parts with Active status such as UPA1C331MPD1TA or UPA1E331MPD1TA.

Q: How do I determine which substitute is appropriate for my application? A: Verify your circuit's voltage requirement. If your design operates at 10 V nominal with no transient overvoltage, UPS1A331MPD1TD provides direct equivalence. If voltage margin is desired, select UPA1C331MPD1TA (16 V). For applications requiring maximum reliability and extended service life, UPA1E331MPD1TA (25 V) with 3000-hour lifetime is optimal.

Request Quote (Ships tomorrow)