Equivalent & Substitute Parts Reference: ULS-5/20-D48P-C

Part Overview

The Murata Power Solutions Inc. ULS-5/20-D48P-C is an isolated DC-DC converter module delivering a regulated 5V output at up to 20A from a 36V to 75V input range, with a 100W power rating. It features remote on/off, OTP, OVP, SCP, and UVLO protection in an 8-DIP Module, 1/16 Brick package. The product status is obsolete, which necessitates the identification of compatible substitute models to ensure continuity in design and maintenance for affected systems.

Substiute Parts

ULS-5/20-D48P-C
Murata Power Solutions Inc.In Stock: 1064ULS-5/20-D48P-C Datasheet
ULS-5/20-D48P-C
Current Part
ULS-5/20-D48N-C
Murata Power Solutions Inc.In Stock: 3253ULS-5/20-D48N-C Datasheet
ULS-5/20-D48N-C
MFR Recommended

Key Parameters

ParameterValue
Manufacturer Part NumberULS-5/20-D48P-C
TypeIsolated Module
Input Voltage Range36V – 75V
Output Voltage5V
Output Current (Max)20A
Power (Watts)100 W
Number of Outputs1
Voltage Isolation2.25 kV
Efficiency91%
Mounting TypeThrough Hole
Package / Case8-DIP Module, 1/16 Brick
Size / Dimension1.30" L x 0.90" W x 0.40" H (33.0mm x 22.9mm x 10.2mm)
Operating Temperature-40°C ~ 85°C
FeaturesRemote On/Off, OTP, OVP, SCP, UVLO
ApplicationsITE (Commercial)
RoHS StatusRoHS Compliant
MSL1 (Unlimited)
REACH StatusREACH Unaffected
ECCNEAR99
HTSUS8504.40.9580
Control FeaturesEnable, Active High

Substitute Part Grouping Explanation

Substitute DC-DC converter modules are selected based strictly on parameters relevant to electrical form, fit, and function as provided. The following criteria establish equivalence, ensuring correct operation and compliance:

  • Type (Isolated Module)
  • Input Voltage Range (36V – 75V)
  • Output Voltage (5V)
  • Output Current (Max 20A)
  • Power Rating (100 W)
  • Number of Outputs (1)
  • Voltage Isolation (2.25 kV)
  • Efficiency (91%)
  • Features (Remote On/Off, OTP, OVP, SCP, UVLO)
  • Operating Temperature Range (-40°C ~ 85°C)
  • Mounting Type (Through Hole)
  • Package / Case (8-DIP Module, 1/16 Brick)
  • Size / Dimension (1.30" L x 0.90" W x 0.40" H)
  • RoHS/REACH/ECCN/HTSUS compliance
  • Moisture Sensitivity Level (1)

Substitute relationships are based exclusively on these matching parameters.

Parameter Comparison

Parameter ULS-5/20-D48P-C ULS-5/20-D48N-C
ManufacturerMurata Power Solutions Inc.Murata Power Solutions Inc.
TypeIsolated ModuleIsolated Module
Input Voltage Range36V – 75V36V – 75V
Output Voltage5V5V
Output Current (Max)20A20A
Power (Watts)100 W100 W
Number of Outputs11
Voltage Isolation2.25 kV2.25 kV
Efficiency91%91%
FeaturesRemote On/Off, OTP, OVP, SCP, UVLORemote On/Off, OTP, OVP, SCP, UVLO
Operating Temperature-40°C ~ 85°C-40°C ~ 85°C
Mounting TypeThrough HoleThrough Hole
Package / Case8-DIP Module, 1/16 Brick8-DIP Module, 1/16 Brick
Size / Dimension1.30" L x 0.90" W x 0.40" H (33.0mm x 22.9mm x 10.2mm)1.30" L x 0.90" W x 0.40" H (33.0mm x 22.9mm x 10.2mm)
Control FeaturesEnable, Active HighEnable, Active Low
ApplicationsITE (Commercial)ITE (Commercial)
RoHS StatusRoHS CompliantROHS3 Compliant
MSL1 (Unlimited)1 (Unlimited)
REACH StatusREACH UnaffectedREACH Unaffected
ECCNEAR99EAR99
HTSUS8504.40.95808504.40.9580
Product StatusObsoleteActive

Engineering Selection Recommendations

Based on the provided data, the ULS-5/20-D48N-C is an active, in-production alternative that meets all electrical, mechanical, and environmental parameters for substitution. RoHS and REACH statuses are equivalent or superseded; both parts carry the same Moisture Sensitivity Level and supply chain classifications. The only control difference is the enable control logic (Active High versus Active Low), which must be considered in control circuit designs—no other differences are indicated within given parameters.

Frequently Asked Questions (FAQ)

Q1: What is the main criteria for substituting ULS-5/20-D48P-C with ULS-5/20-D48N-C?
A: Substitution is based on identical input/output voltage and current, power rating, isolation, features, mounting, size, package type, compliance, and environmental ratings.

Q2: Are there any differences in control logic between the original and substitute part?
A: Yes, the ULS-5/20-D48P-C has an 'Enable, Active High' control feature, while the ULS-5/20-D48N-C uses 'Enable, Active Low.' This must align with system control signal requirements.

Q3: Do both modules fit the same PCB and footprint?
A: Yes, both are specified in the 8-DIP Module, 1/16 Brick package with the same dimensions and through-hole mounting.

Q4: Is there any difference in compliance or environmental classifications?
A: No. Both parts are RoHS and REACH compliant, with MSL 1 (Unlimited), and share the same ECCN and HTSUS categorizations.

Q5: Is thermal performance or efficiency compromised with the substitute part?
A: No. Both specify an efficiency of 91% and an operating temperature range of -40°C to 85°C.

Q6: Can both modules be replaced without design or qualification changes?
A: Based on the provided parameters, all functional and mechanical specifications match except for enable logic polarity, which must be addressed at the system design level if necessary.

Request Quote (Ships tomorrow)